• & <br /> Harpreet Bal <br /> Plan Check Number: BW2012-004, First Building Review <br /> October 18, 2021 <br /> Architectural <br /> 1. See Schematic Plan on Sheet A1.0, A2.0, and A2.2. All unpermitted work should be identified as <br /> new even if it is currently existing in-place. If preferred, use two designations on the drawings <br /> to distinguish between existing construction being permitted and new construction. The <br /> Foundation Floor Plan should show the existing crawl space in the Proposed Master Bedroom as <br /> new. Plans should provide crawl space ventilation and attic ventilation for the proposed master <br /> bedroom area. <br /> 2. See Sheet A2.0 It appears that the window in the proposed master bedroom does not meet the <br /> minimum opening requirements for an emergency escape and rescue opening. Windows should <br /> have a net clear opening of not less than 5.7 square feet to qualify for an egress window. The <br /> plans should provide a qualifying egress window in the proposed master bedroom. R310.2.1 <br /> 3. The following should be provided for the east porch: <br /> a. Framing plans and details for the porch, stairs, and roof cover. <br /> b. Material and fastener requirements. <br /> c. Deck details should be referenced on the plans where they occur. <br /> 4. See Energy Code Summary on Sheet A2.1. It appears that energy credit 1.3 is selected which <br /> makes modifications to Table R402.1.1 of Vertical fenestration U = 0.28, and floor insulation of <br /> R-38. Plan notes and details should be updated to specify R-38 insulation within the floor and <br /> windows to have a U factor of 0.28. WSEC Table R406.3 <br /> 5. See Energy Code Summary on Sheet A2.1. Based on the selected energy credit 2.1, the note for <br /> building air leakage and testing should be updated to 3.0 air changes per hour maximum at 50 <br /> pascals. WSEC Table R406.3 <br /> 6. See Energy Code Summary on Sheet A2.1. The minimum equipment efficiency should be stated <br /> for the heat pump according to selected energy credit 3.4. WSEC Table R406.3 <br /> 7. See Energy Code Summary on Sheet A2.1. The Lighting Note should be updated to specify 90% <br /> of permanently installed lighting fixtures to be high efficacy lamps. WSEC R404.1 <br /> 03200 Cedar Street 0 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.