My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
620 112TH ST SE SPACE 330 2023-08-01
>
Address Records
>
112TH ST SE
>
620
>
620 112TH ST SE SPACE 330 2023-08-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2023 1:40:25 PM
Creation date
8/1/2023 1:39:45 PM
Metadata
Fields
Template:
Address Document
Street Name
112TH ST SE
Street Number
620
Unit
SPACE 330
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 4i0 <br /> Mr. Chad Georgell <br /> Rainier Structures, LLC <br /> Plan Check Number: C2006-007, First Building Review <br /> August 12, 2020 <br /> Structural <br /> 1. The foundation design for the proposed project should comply with the requirements of the <br /> 2015 International Building Code. The code should be specified in construction drawings. See <br /> the Everett Municipal Code Section 16.005.030 Article A and IBC Section 107.2.1. <br /> 2. The submitted documents do not include a project specific foundation design. Note that <br /> general requirements included in the manufacturer's published literature do n6t satisfy this <br /> required. A foundation plan and details should be included in the construction drawings. <br /> Structural calculations substantiating the foundation design, including the transfer of lateral <br /> forces (i.e., seismic and wind loads) to the foundation, should be submitted for review. See IBC <br /> Sections 1604.1, 1604.2, and 1604.4. <br /> 3. Structural and geotechnical special inspections may be required for this project where the <br /> design is performed per the IBC, including inspections for deep foundation elements (i.e., soil <br /> anchors). The statement should include a table listing each type of special inspection and the <br /> extent of each inspection (e.g., continuous, periodic) per IBC Section 1704.3.1. The table <br /> should include special requirements for seismic and wind resisting systems as required by IBC <br /> Sections 1704.3.2 and 1704.3.3, respectively. See IBC Sections 107.1, 1704.2.3 and 1704.3. <br /> 4. The submitted documentation does not include a geotechnical report providing criteria for use <br /> in the design of the foundation. A geotechnical evaluation should be performed and a report <br /> provided for review. Alternatively, the presumptive design criteria for use in the design should <br /> be established. In either case, the design criteria should be stated in the construction <br /> drawings. Note that the presumptive criteria must be verified by special inspection testing <br /> during construction; failure to meet the criteria may require modifications to the design during <br /> construction to satisfy the design requirements. See IBC Sections 1803.1 and 1803.6. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Drew Martin, P.E., S.E. <br /> Associate Engineer/ Commercial Plans Examiner <br /> (425)257-8813 <br /> dmartin@everettwa.gov <br /> O3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> ' Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.