My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
709 80TH ST SW VERIZON WIRELESS 2025-08-08
>
Address Records
>
80TH ST SW
>
709
>
VERIZON WIRELESS
>
709 80TH ST SW VERIZON WIRELESS 2025-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2025 2:13:55 PM
Creation date
8/8/2023 2:47:21 PM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
709
Tenant Name
VERIZON WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SITE PLAN NOTES: <br /> 1. THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN.THE CONTRACTOR SHALL VISIT THE SITE <br /> PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. <br /> s <br /> 2. ICE BRIDGE,CABLE LADDER,COAX PORT,AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL <br /> PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN.BEFORE UTILIZING EXISTING CABLE SUPPORTS,COAX PORTS,INSTALLING NEW AMERICAN TOWER• <br /> PORTS OR ANY OTHER EQUIPMENT,CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. <br /> ATC TOWER SERVICES,LLC <br /> 3. THIS PROJECT INCLUDES NO INSTALL OR MODIFICATION AT GRADE. 3500 REGENCY PARKWAY <br /> SUITE 100 <br /> CARY,NC 27518 <br /> PHONE:(919)468-0112 <br /> COA:3408 <br /> LEGEND <br /> ® GROUNDING TEST WELL C O R E ONE <br /> ATS AUTOMATIC TRANSFER SWITCH <br /> o <br /> B BOLLARD CONSULTING USA <br /> CSC CELL SITE CABINET t - '• .. - '.••' <br /> D DISCONNECT — f 4515 S.MCCLINTOCK DRIVE,SUITE 217 <br /> E ELECTRICAL CON. PAD PROPOSED TEMPE,AZ 85282 <br /> F FIBER (1)OVP12 <br /> GEN GENERATOR - <br /> G GENERATOR RECEPTCLE <br /> REV. DESCRIPTION BY DATE <br /> HH,V HAND HOLE,VAULT EXISTING <br /> IB ICE BRIDGE (6) / Z . PRELIM REG 07/14/21 <br /> L L DIFLEXER <br /> K KENTROX BOX 22'-0" X 25'-6'" (TO BE REMOVED) QO 100% CD REG 07/14/21 <br /> LC LIGHTING CONTROL SHELTER <br /> M METER A <br /> EXISTING - <br /> PB PULL BOX (1) OVP6 TO REMAIN A - <br /> PP POWER POLE A — <br /> T TELCO <br /> TRN TRANSFORMER ATC SITE NUMBER: <br /> CHAINLINK FENCE 83067 <br /> ATC SITE NAME: <br /> SOUTH EVERETT <br /> I <br /> t� I VERIZON SITE NAME: <br /> 0 4"= L. i WASE SOUTH EVERETT <br /> i:� -�R.y,� r �� i _� ! (E) H—FRAME <br /> �44, <br /> , A/C A/C , „ii SITE ADDRESS: <br /> i I PROPOSED 709 80ST SW <br /> 12X24 HYBRID CABLE EVERETT,WA 98203 <br /> � 2� PB -IB' (1) <br /> az <br /> GEN. EXISTING SEAL: <br /> --'-'� (1) 6X12 HYBRID CABLE .)►�a1t� <br /> U I LATTICE I-'-='Till CHAINLINK FENCE t <br /> 1 TOWER I I W/3-STRAND <br /> 1 I BARBED WIRE <br /> M14M 1 L.110.1 & PRIVACY SLATS fp, <br /> J //~ <br /> ---` 2'-2"X 4'-4" OE <br /> ���•���///777 <br /> 4 ' TRN GEN. M • / <br /> r • PUBLIC TRANSIT aK 56058 / <br /> • <br /> BO e , 3'-0""X 4'-0" ��� �E Fri �� <br /> CISTER \ <br /> FSS/pNAI �-�� <br /> V \\/ <br /> I EXISTING 16'-0" II <br /> WIDE GATE vet'izori ' <br /> PROPOSED CABLE LENGTH: <br /> 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 180'. <br /> ESTIMATED LENGTH OF CABLE WAS PROVIDED BY <br /> CUSTOMER OR CALCULATED BY ADDING THE RAD <br /> DATE DRAWN: <br /> CENTER AND THE DISTANCE FROM THE SHELTER 07/14/21 <br /> ENTRY PLATE TO THE TOWER(ALONG THE ICE ATC JOB NO: 13671799_G5 <br /> BRIDGE)AND A SAFETY FACTOR MEASUREMENT OF <br /> CUSTOMER ID: WASE SOUTH EVERETT <br /> 15%(OF THE TWO PREVIOUS VALUES),CDS DEFER <br /> TO GREATEST CABLE LENGTH, CUSTOMER#: 102287 <br /> 2. ROUTE PROPOSED CABLES ALONG SAME PATH AS <br /> EXISTING CABLES AND IN ACCORDANCE WITH <br /> STRUCTURAL ANALYSIS.WHERE POSSIBLE UTILIZE O DETAILED SITE PLAN <br /> EXISTING CABLE SUPPORT STRUCTURES AS DETAILED SITE PLAN <br /> PROVIDED FOR CARRIER TO ADEQUATELY SECURE <br /> CABLES,USING EITHER APPROPRIATELY SIZED GRAPHIC SCALE <br /> STAINLESS STEEL SNAP-INS OR MOUNTING <br /> 0 <br /> MANUFACTURER.OTHERWISE,ATTACH CABLES TOHARDWARE AND BRACKETS AS SPECIFIED BYE 10 Emil 10 SHEET NUMBER: REVISION: <br /> HORIZONTAL OR DIAGONAL TOWER MEMBERS 101 0 <br /> USING PROPOSED STAINLESS STEEL ADAPTERS(DO (IN FEET) <br /> NOT ATTACH TO TOWER LEG). 1 UNIT=10 FEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.