My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7333 BEVERLY LN 2023-09-25
>
Address Records
>
BEVERLY LN
>
7333
>
7333 BEVERLY LN 2023-09-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2023 10:27:57 AM
Creation date
8/22/2023 7:05:50 AM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY LN
Street Number
7333
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> DY /r►Awww.dykeman.net 1716 West Marine View Drive <br /> 425.259.3161 (T) 2nd Floor/Everett,WA 98201 <br /> March 16, 2021 <br /> To: James Bronder, City of Everett <br /> RE: Fountainhead Apartments repairs—Permit application B2203-023 <br /> Mr. Bronder, Please see enclosed our responses to City Comments which we received on March 14 of <br /> this year for the proposed repairs at Fountainhead apartments 7333 Beverly Lane. <br /> 1. On Sheet G0.2, callouts on the drawings refer to details Al, A2 on A8.10, but do not appear to be <br /> provided on the drawing set. Please clarify. <br /> The references to A8 sheets are outdated, and the reference should be to sheet BE000. This <br /> has been corrected on the updated sheets provided with this resubmittal. <br /> 2. The Type of Construction on the set is indicated to be V-1 hour. Per IBC 705.2.3.1, balconies and <br /> similar projections are required to meet the fire-resistive construction for floor construction of that <br /> Type. It is unclear if the repair to the assembly will include replacement of floor assembly <br /> construction materials. If so, please indicate a floor assembly listing that maintains the fire-resistive <br /> construction requirements. <br /> The soffit materials shall be 5/8"type X exterior soffit board,with painted fiber cement <br /> panels. The full assembly corresponds closely to UL design L507,which is rated at 1 hr. It <br /> also corresponds to the 1 hr.assembly described on the original plans from 1968. In the <br /> original drawings,the soffit was described as "'h" duraply over'/z" gypsum board." This <br /> assembly is described in the updated drawing provided with this resubmittal. <br /> We hope these responses meet your needs. Please call or email if you have any further questions. <br /> Sincerely, <br /> Doug Hofius RECEIIIVE <br /> N►AIZ 2 1 at. <br /> CITY OF EVERETT <br /> Permit Services <br /> 1967 <br /> ARCHITECTURE + DESIGN 2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.