STRING CALCULATIONS <br />ENPHASE: IQ8M-72-2-US (240V) <br />STRING #1 <br />STRING #2 <br />STRING #3 <br />MAX AC CURRENT <br />16.93A <br />16.93A <br />16.93A <br />MICRO INVERTER(S) IN SERIES: <br />10 <br />10 <br />10 <br />NOMINAL VOLTAGE / RANGE 2: <br />211V - 264V <br />211V - 264V <br />211V - 264V <br />MAX AC OUTPUT POWER: <br />3250W <br />3250W <br />3250W <br />ARRAY DC POWER: <br />1440OW <br />TOTAL MAX AC CURRENT: <br />40.63A <br />NUMBER OF CURRENT CARRYING CONDUCTORS <br />PERCENT OF VALUES <br />4-6 <br />.80 <br />7-9 <br />.70 <br />10-2 0 <br />.50 <br />SYSTEM OCPD CALCULATIONS <br />INVERTER MODEL(S): <br />ENPHASE IQ8M-72-2-US (240V) <br /># OF INVERTER(S): <br />30 <br />MAX OUTPUT CURRENT: <br />1.35A <br />(# OF INVERTERS) X (MAX OUTPUT CURRENT) X 125% <= OCPD RATING <br />(30 X 1.35A X 1.25) = 50.78A <= 60A, OK <br />PV LOAD CALCULATIONS: SUPPLY SIDE TIE-IN <br />FEEDER WIRE RATING: <br />200A <br />ALLOWABLE SOLAR CALCULATION <br />(FEEDER RATING - 1.25) <br />160.000OA (FEEDER WIRES ALLOWABLE SOLAR) <br />160.000OA (AVAILABLE FOR PV) <br />Conduit & Conductor Schedule <br />TAG <br />QTY <br />WIRE GAUGE <br />DESCRIPTION <br />CONDUIT SIZE <br />CONDUCTOR RATING <br />CONDUCTOR TEMP. RATE <br />AMBIENTTEMP <br />TEMP. DERATE <br /># OF CONDUCTORS <br />DERATE <br />CONDUCTOR RATING <br />W/DERATES <br />CONDUIT FILL <br />1 <br />(2) <br />10 AWG <br />Q-CABLE , COPPER (L1, L2) <br />N/A - FREE AIR <br />40A <br />901C <br />26'C <br />1.0 <br />N/A - FREE AIR <br />40A <br />N/A - FREE AIR <br />(1) <br />6 AWG <br />THWN-2 COPPER - (GROUND) <br />2 <br />(2) <br />10 AWG <br />THHN/THWN-2, COPPER - (L1, L2) <br />3/4" EMT <br />40A <br />901C <br />26'C <br />1.0 <br />1.0 <br />40A <br />11.45 <br />(1) <br />10 AWG <br />THWN-2 COPPER - (GROUND) <br />3 <br />(6) <br />10 AWG <br />THHN/THWN-2, COPPER - (L1, L2) <br />3/4" EMT <br />40A <br />901C <br />26'C <br />1.0 <br />0.8 <br />32A <br />26.72 <br />(1) <br />10 AWG <br />THWN-2 COPPER - (GROUND) <br />4 <br />(3) <br />6 AWG <br />THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) <br />3/4" EMT <br />75A <br />901C <br />26'C <br />1.0 <br />1.0 <br />75A <br />36.53 <br />(1) <br />6 AWG <br />THWN-2 COPPER - (GROUND) <br />5 <br />(3) <br />6 AWG <br />THHN/THWN-2, COPPER - (L1, L2, NEUTRAL) <br />3/4" RMC/IMC <br />65A <br />75'C <br />26'C <br />1.0 <br />1.0 <br />65A <br />35.49 <br />(1) <br />6 AWG <br />THWN-2 COPPER - (GROUND) <br />GROUNDING & GENERAL NOTES: <br />1. PV INVERTER IS UNGROUNDED, TRANSFORMER -LESS TYPE. <br />2. DC GEC AND AC EGC TO BE SPLICED TO EXISTING ELECTRODE <br />3. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO <br />BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. <br />4. JUNCTION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - <br />JUNCTION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE <br />TRANSITIONS. <br />5. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER <br />AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. <br />INTERCONNECTION NOTES: <br />1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCE DETERMINED IN ACCORDANCE WITH [NEC <br />705.12], AND [NEC 690.64]. <br />2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9], [NEC 230.95] AND [NEC 690.5] <br />3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. <br />4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUSBAR RELATIVE TO THE MAIN BREAKER. <br />DISCONNECT NOTES <br />1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS <br />REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED "LINE SIDE" (TYPICALLY THE UPPER TERMINALS) <br />2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A <br />VISIBLE -BREAK SWITCH <br />nr <br />lwvgu�qm <br />5 L A R <br />Revolution Energy Systems Inc. <br />9981 West 190th St <br />Unit K Mokena IL 60448 <br />T: 708-995-1643 <br />SITE INFORMATION <br />PAULA KATHLEEN HOLLCRAFT <br />21E E MCGILL AVE <br />EVERETT, WA 98208 <br />AC System Size: 9.75 kW AC / 9.75 kVA <br />DC System Size: 14.40 kW DC <br />Lat, 47.9122656 <br />Long,-122.2320191 <br />(30) HANWHA Q.PEAK DUO XL-G10.2 480 <br />PV Modules <br />(30) ENPHASE IQ8M-72-2-US (240V) <br />Inverter(s) <br />SNOHOMISH COUNTY PUD <br />DRAWN BY: M. MONTEMOR <br />DATE: <br />10/27/2022 <br />ELECTRICAL CALCS - PV06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.