Laserfiche WebLink
A\ WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />/!� WARNING Aml <br />THIS EQUIPMENT IS FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />/!� WARNING 1 <br />INVERTER OUTPUT CONNECTION <br />DO NOT RECOLCATE <br />THIS OVERCURRENT <br />DEVICE <br />/!� WARNING J <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND PV <br />SOLAR ELECTRIC SYSTEM <br />I DRFI IKir KinTCC <br />LABEL 1 <br />FOR PV DISCONNECTING MEANS WHERE THE LINE AND <br />LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN <br />POSITION. <br />[NEC 690.13(B)] <br />LABEL 2 <br />PLACED ADJACENT TO THE BACK -FED BREAKER FROM <br />THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE <br />CONNECTIONTO BUSBAR. <br />[NEC 705.12(13)(2)(3)(b)] <br />LABEL 3 <br />PLACED ADJACENT TO THE BACK -FED BREAKER <br />FROM THE INVERTER IF TIE IN CONSISTS OF LOAD <br />SIDE CONNECTION TO BUSBAR. <br />[NEC 705.12(13)(2)(3)(c)] <br />LABEL4 <br />EQUIPMENT CONTAINING OVERCURRENT <br />DEVICES IN CIRCUITS SUPPLYING POWER TO A <br />BUSBAR OR CONDUCTOR SUPPLIED FROM <br />MULTIPLE SOURCESSHALL BE MARKEDTO MAIN SERVICE PANEL <br />INDICATE THE PRESENCE OF ALL SOURCES <br />[NEC 705.12(B)(3)] <br />LABEL 5 <br />AT POINT OF INTERCONNECTION, MARKED AT <br />AC DISCONNECTING MEANS. <br />[NEC 690.54, NEC 690.13 (B)] <br />1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT <br />REQUIREMENTS IN THE FIELD PER CURRENT NECAND LOCAL CODESAND MAKE APPROPRIATE ADJUSTMENTS. <br />2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI <br />Z535. <br />3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />4. LABELSTO BE OF SUFFICIENT DURABILITYTO WITHSTANDTHE ENVIRONMENT INVOLVED [NEC 110.21(B)(3)] <br />5. LABELSTO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND <br />PERMANENTLY AFFIXED [I FC 605.11.1.11 <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWICH TO THE"OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />lt <br />SHOCK HAZARD IN ARRAY <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />CONDUCTORS OUTSIDE <br />THE ARRAY. CONDUCTOR: <br />NITHIN THE ARRAY REMAIf <br />ENERGIZED IN SUNLIGHT <br />LABEL 6 <br />AT DIRECT -CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERSAND <br />ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED <br />AT MAXIMUM LOFT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, <br />PARTITIONS, CEILINGS, OR FLOORS. <br />[NEC 690.31(G)(3&4)] <br />LABEL 7 <br />FOR PV SYSTEMSTHAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING <br />THE ARRAY: <br />SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND <br />SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br />SWITCHES IF NOT AT THE SAME LOCATION. <br />[NEC 690.56(C)(1)(A)] <br />LABEL 8 <br />FOR PV SYSTEMSTHAT ONLY SHUT DOWN CONDUCTORS <br />LEAVING THE ARRAY: <br />SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY <br />FROM SERVICE DISCONNECTING MEANSTO WHICH THE <br />PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE <br />LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN <br />SWITCHES IF NOT AT THE SAME LOCATION. <br />[NEC 690.56(C)(1)(b)] <br />LABEL 9 <br />SIGN LOCATED AT RAPID SHUT DOWN <br />DISCONNECT SWITCH [NEC 690.56(C)(3)]. <br />0 <br />O O <br />3O O4 <br />EXISTING SUB PANEL LABELING DIAGRAM: PV COMBINER <br />(IF WHERE POINT OF SUBPANEL- <br />INTERCONNECTION IF USED TO COMBINE <br />IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS <br />INVERTER(S) <br />O <br />DI <br />O O O O O <br />O O <br />O O O <br />O <br />l <br />�o <br />oc <br />O <br />O <br />(ONLY IF PV <br />INTERCONNECTION <br />CONSISTSOF LOAD <br />(ONLY IF PV <br />INTERCONNECTION <br />CONSISTS OF LOAD <br />❑ O O <br />SIDE BREAKER) <br />SIDE BREAKER) <br />INTEGRATED DC DISCONNECT <br />O <br />JUNCTION BOX <br />OR COMBINER BOX <br />O <br />"ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSESONLY. NOTANACTUAL REPRESENATION OF EQUIPMENTAND CONNECTIONSTO BE INSTALLED. LABEL LOCATIONS <br />PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON THE ELECTRICAL DIAGRAM PAGE. <br />+fir ��L <br />■■affra �1 <br />f 1j� <br />Revolution Energy Systems Inc. <br />9981 West 190th St <br />Unit K Mokena IL 60448 <br />T: 708-995-1643 <br />SITE INFORMATION <br />PAULA KATHLEEN HOLLCRAFT <br />PAIaaM141011W9Vq <br />EVERETT, WA 98208 <br />AC System Size: 9.75 kW AC / 9.75 kVA <br />DC System Size: 14.40 kW DC <br />Lat, 47.9122656 <br />Long,-122.2320191 <br />(30) HAN WHA Q.PEAK DUO XL-G10.2 480 <br />PV Modules <br />(30) ENPHASE IQ81V-72-2-US (240V) <br />Inverter(s) <br />SNOHOMISH COUNTY PUD <br />DRAWN BY: M. MONTEMOR <br />DATE: <br />10/27/2022 <br />LABELS - PV07 <br />