Laserfiche WebLink
PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />18 MODULES -ROOF MOUNTED - 7.200 kWDC, 5.220 kWAC <br />SYSTEM SUMMARY: <br />(N) 18 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES <br />(N) 18 - ENPHASE ENERGY IQ8PLUS-72-2-US MICRO -INVERTERS [240V] <br />(N) JUNCTION BOX <br />(N) 200A MAIN SERVICE PANEL WITH (N) 200A MAIN BREAKER <br />(N) ENPHASE IQ COMBINER 4 [240V] <br />X2-IQ-AM1-240-4 (IEEE 1547.2018) <br />(N) PRODUCTION METER <br />(N) 30A NON -FUSED AC DISCONNECT [240V] <br />MSP UPGRADE: YES <br />DESIGN CRITERIA - <br />ROOF TYPE: - ASPHALT SHINGLES <br />NUMBER OF LAYERS: - 01 <br />ROOF FRAME: - 2"X4" RAFTERS @ 24" O.C. <br />STORY: - ONE STORY <br />SNOW LOAD : - 25 PSF <br />WIND SPEED :- 110 MPH <br />WIND EXPOSURE:- B <br />RISK CATEGORY:- II <br />COORDINATE:- 47.942890,-122.220024 <br />GOVERNING CODES: <br />2020 NATIONAL ELECTRICAL CODE (NEC) <br />2018 INTERNATIONAL BUILDING CODE <br />2018 INTERNATIONAL EXISTING BUILDING CODE <br />2018 INTERNATIONAL SWIMMING POOL AND SPA CODE <br />2018 INTERNATIONAL FIRE CODE <br />2018 WASHINGTON STATE ENERGY CODE <br />2018 INTERNATIONAL RESIDENTIAL CODE <br />2018 INTERNATIONAL MECHANICAL CODE <br />2018 UNIFORM PLUMBING CODE <br />.qHFFT INnFX <br />PV-0 <br />COVER SHEET <br />PV-1 <br />SITE PLAN WITH ROOF PLAN <br />PV-2 <br />ROOF PLAN WITH MODULES <br />PV-3 <br />ATTACHMENT DETAILS <br />PV-4 <br />ELECTRICAL LINE DIAGRAM WITH <br />CALCULATION <br />PV-5 <br />WARNING LABELS & PLACARD <br />PV-6+ <br />EQUIPMENT SPEC SHEETS <br />6027 DEXTER AVE, EVERETT, WA 98203, USA <br />NOTES: <br />1. PHOTOVOLTAIC SYSTEM EQUIPMENT SHALL BE INSTALLED IN <br />ACCORDANCE WITH NEC 2020 ARTICLES 690 AND 705, AND THE 2018 <br />IRC/IBC & 2018 INTERNATIONAL FIRE CODE, AND APPLICABLE <br />REQUIREMENTS OF THE SERVICE UTILITY AND AUTHORITY HAVING <br />JURISDICTION. PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE POSTED <br />WITH APPLICABLE WARNINGS, SIGNAGE AND PLAQUES PER NEC 690.13, <br />705.10 AND 706.15. <br />2. PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL COMPLY WITH <br />THE WIRING METHODS AND INSTALLATION AND MARKING <br />REQUIREMENTS OF NEC 690.31(D). <br />3. BREAKER LABELED "PHOTOVOLTAIC ELECTRIC POWER SOURCE" AND <br />"BREAKERS ARE BACK FED" PER NEC 705.12(D) & NEC 690.59. BREAKER <br />ALSO LABELED "MAXIMUM AC OUTPUT CURRENT AND OPERATING AC <br />VOLTAGE" PER NEC 690.54. BREAKER SHALL BE POSITIONED AT THE <br />OPPOSITE (LOAD) END FROM THE INPUT FEEDER OR MAIN CIRCUIT <br />BREAKER LOCATION, AND LABELED "WARNING INVERTER OUTPUT <br />CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE", PER <br />NEC 705.12 (13)(3)(2). <br />4. WARNING SIGN PER NEC 706.15(C)(4) and NEC 690.13(B) READING <br />"WARNING - ELECTRIC SHOCK HAZARD - TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION." <br />5. LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH." SWITCH <br />TO BE LOCKED PER NEC 690.13(B). SWITCH TO BE VISIBLE BLADE <br />DISCONNECT PER UTILITY REQUIREMENTS AND CONFORM TO NEC <br />705.22. <br />6. LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER NEC <br />690.13(B). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE, <br />MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC <br />690.53. SWITCH LOCKED PER NEC 690.13(B). <br />7. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER <br />INVERTER(S) AND SOLAR MODULES PER NEC 110.3 (B). <br />8. LABELED PHOTOVOLTAIC SYSTEM DEDICATED KWH METER. (NOT USED) <br />9. BI-DIRECTIONAL METER TO BE INSTALLED BY UTILITY. <br />10. DEDICATED PHOTOVOLTAIC COMBINER SUB -PANEL. LABEL "LOADS NOT <br />TO BE ADDED TO THIS PANEL." <br />11. ALL LABELS EXPOSED TO SUNLIGHT MUST BE ENGRAVED AND <br />ATTACHED PER APPROVED METHOD. <br />12. LABEL "BREAKER HAS BEEN DE -RATED PER NEC 705.12(B)(3)." NO NEW <br />LOADS. <br />13. EXISTING EQUIPMENT IS NOTED WITH A DASHED LINE. SOLID LINES <br />DENOTE EQUIPMENT INSTALLED BY ELECTRICAL CONTRACTOR. <br />14. WIRE MAY BE RUN SHORT DISTANCES OUTSIDE OF CONDUIT IF WIRE <br />READS "SUNLIGHT RESISTANT." <br />15. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE CONTINUOUS AND <br />TERMINATE WITH AN IRREVERSIBLE CONNECTION TO THE AC <br />GROUNDING ELECTRODE SYSTEM PER NEC 250.64(B). <br />16. AMBIENT TEMPERATURE ADJUSTED FOR CONDUITS EXPOSED TO <br />SUNLIGHT ON OR ABOVE ROOFTOPS PER TABLE 310.15 (13)(2). CONDUIT <br />ELEVATED MIN. 1/2"; ADDER 33 DEG F. <br />17. ALL EXTERIOR EQUIPMENT TO BE NEMA 3R. <br />18. THE PHOTOVOLTAIC POWER SOURCE SHALL BE LABELED WITH THE <br />FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, <br />DISCONNECT AND DEVICE WHERE ENERGIZED, UNGROUNDED CIRCUITS <br />MAY BE EXPOSED DURING SERVICE: <br />WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED <br />VERSION <br />DESCRIPTION DATE REV <br />I INITIAL RELEASE 106/15/2023 I UR <br />1 AERIAL PHOTO <br />PROJECT NAME <br />PV-0 SCALE: NTS <br />O <br />O <br />000 <br />Port of Everett Everett Statp Roi <br />W C) <br />15 <br />W <br />O <br />4. <br />�> M O= <br />O <br />EVERETT <br />JUNCTION - Everett Memorial <br />Stadium <br />W Q N 0 w W <br />i <br />WxQM= <br />m <br />LOWELL <br />W O O <br />DARLINGTON <br />z <br />.. <br />6027 Dexter Ave, <br />� CD <br />ILO w 0- <br />W <br />Everett, WA 982030 <br />i Q J Q <br />0�/ <br />' United States <br />W � <br />(.VALLEY VIEW <br />a26 <br />SHEET NAME <br />Paine INTERCITY <br />Field <br />COVER SHEET <br />Everett Mall <br />M <br />SHEET SIZE <br />2 VICINITY MAP N <br />ANSI B <br />11"X17" <br />PV-0 SCALE: NTS <br />SHEET NUMBER <br />W E <br />PV-0 <br />S <br />