Laserfiche WebLink
AREA A <br />--�s a, ------------ ---- <br />I � <br />® I ill <br />5 <br />A" N 1 ST FLOOR EXIT PLAN <br />1 . SCALE: 1/16"=1'-O" <br />SEE SHEET 1-0.1 FOR PLUBING <br />CALCULATIONS <br />r <br />r------------------ <br />I <br />AREA B <br />- - - - - - - - - - - - - - - - - - - - - - 7 - - - - - - - -- <br />EMO <br />M <br />Ov <br />F <br />O <br />r 0 o� <br />°m ' <br />o <br />o g- <br />In <br />VW 0 O�rJ <br />� I I <br />-II <br />0. <br />Code Calculations: <br />N <br />1. REQUIRED EGRESS WIDTH: <br />1.1. <br />EGRESS WIDTHS REQUIRED PER IBC 1005.3.1 & 1005.3.2: <br />1.2. <br />STAIRS: 0.3"/OCCUPANT <br />1.3. <br />OTHER COMPONENTS: 0.2"/OCCUPANT <br />U <br />2. <br />MAXIMUM OCCUPANT LOAD LIMITED BY STAIRWAYS: N/A <br />3. <br />MAXIMUM OCCUPANT LOAD LIMITED BY OTHER EGRESS COMPONENTS: <br />w <br />AREA A. 544' (TOTAL WIDTH) / 0.2 = 2720 MAXIMUM OCCUPANTS <br />4. <br />(2) MINIMUM EXITS REQUIRED PER IBC 1006.2.1/1006.3.2. <br />(15) EXITS HAVE BEEN PROVIDED. <br />O <br />S. <br />ALL CONFERENCE ROOMS UNDER 50 OCCUPANTS (OR 750 SF) TO BE <br />N <br />CONSIDERED B OCCUPANCY PER IBC 303.1.2. <br />6. <br />"COMMON PATH OF EGRESS TRAVEL" FOR B OCCUPANCY TO BE <br />N}�/ <br />9 <br />100'-0" OR LESS (75'-0" WITHOUT OR SPRINKLERS THROUGHOUT <br />00-0 <br />LLI <br />BLDG) AS ALLOWED PER IBC TABLE 1006.2.1. <br />Z O <br />N <br />7. <br />"EXIT ACCESS TRAVEL DISTANCE" FOR B OCCUPANCY TO BE 300'-0" <br />O <br />00 <br />OR LESS (200'-0- WITHOUT OR SPRINKLERS THROUGHOUT BLDG) C <br />ALLOWED PER IBC TABLE 1017.2. <br />Q Q <br />7.1. <br />EXIT TRAVEL DISTANCE SHALL BE MEASURED TO EXIT DISCHARGE <br />s <br />OR EXIT STAIR, BUT CONTINUE DOWN A EXIT ACCESS STAIR. <br />N <br />S. <br />DEAD-END CORRIDORS TO BE LESS THAN 20'-0". (50'-0" IF FULLY <br />N <br />SPRINKLERED AND B, E, F, OR S OCCUPANCY) PER IBC 1020.4. <br />c) N <br />01 OO <br />oO 0 i <br />® <br />IS-LJ I <br />p, <br />p <br />� <br />I� <br />J <br />® <br />i <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />ZAP ENERGY <br />Opus Seaway <br />Floor 1 & 2 <br />2300 Merrill Creek Pkwy <br />Everett, WA <br />FLOOR 1 OCCUPANT LOAD: <br />REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR <br />Occupancy <br />Room Name <br />Room <br />Number <br />Square <br />Footage <br />Load <br />Factor <br />Occupant <br />Load <br />FLOOR 1 AREA A <br />B <br />OPEN OFF <br />1,394 <br />150 <br />9.3 <br />B <br />OFFICE <br />136 <br />110 <br />150 <br />0.7 <br />B <br />OFFICE <br />140 <br />104 <br />150 <br />0.7 <br />B <br />FOCUS <br />141 <br />87 <br />150 <br />0.6 <br />DESIGN JPC <br />DRAWN NB/AG <br />CHECKED TP <br />NO. 22 0799 <br />fi189 REGISTERED <br />A ECT <br />w <br />MARK a. PETERSON <br />STATE OF WASHINGTON <br />02-17-2023 PERMIT SET <br />B <br />Focus <br />142 <br />$4 <br />150 <br />os <br />AREA A <br />TOTAL <br />TOTAL <br />AREA: <br />1 779 <br />TOTAL <br />occ: <br />12 <br />FLOOR 1 AREA B <br />A3 <br />CAFE <br />101 <br />795 <br />15 <br />53.0 <br />B <br />KITCHEN <br />102 <br />378 <br />15 <br />25.2 <br />of <br />J <br />O <br />B <br />BIKE/LKR <br />105 <br />460 <br />150 <br />3.1 <br />B <br />MEETING <br />106 <br />160 <br />15 <br />10.7 <br />B <br />OPEN OFF <br />108 <br />1,997 <br />150 <br />13.3 <br />B <br />OFFICE <br />109 <br />1 115 <br />150 <br />0.8 <br />B <br />OFFICE <br />110 <br />120 <br />150 <br />0.8 <br />B <br />MEETING <br />111 <br />120 <br />15 <br />8.0 <br />B <br />OPEN OFF <br />116 <br />1,929 <br />150 <br />12.9 <br />ELECTRIC <br />117 <br />139 <br />300 <br />0.5 <br />B <br />MEETING <br />118 <br />240 <br />15 <br />1&0 <br />B <br />MEETING <br />119 <br />237 <br />15 <br />15.8 <br />B <br />OFFICE <br />120 <br />163 <br />150 <br />1.1 <br />B <br />OFFICE <br />121 <br />126 <br />150 <br />0.8 <br />B <br />OFFICE <br />122 <br />126 <br />150 <br />0.8 <br />B <br />OFFICE <br />123 <br />126 <br />150 <br />0.$ <br />B <br />OFFICE <br />124 <br />126 <br />150 <br />0.8 <br />B <br />OFFICE <br />125 <br />1,733 <br />150 <br />11.6 <br />B <br />MEETING <br />133A <br />505 <br />15 <br />33.7 <br />B <br />MEETING <br />133E <br />455 <br />15 <br />30.3 <br />B <br />MEETING <br />134 <br />140 <br />15 <br />9.3 <br />ELECTRIC <br />117 <br />490 <br />300 <br />1 <br />1.6 <br />1 <br />AREA B <br />TOTAL <br />TOTAL <br />AREA: <br />10190 <br />TOTAL <br />Of <br />249 <br />TOTAL <br />AREATOTA <br />11,969 <br />OCCAL <br />261 <br />Key Notes: NOT ALL KEYNOTES ARE USED ON THIS SHEET. <br />Qj NEW OR EXISTING BUILDING STANDARD EXIT LIGHT. GC TO VERIFY <br />EXISTING EXIT LIGHT LOCATIONS AS SHOWN. <br />42 NEW BUILDING STANDARD FIRE EXTINGUISHER AND CABINET. <br />Q3 ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. <br />® ADA CLEAR FLOOR SPACE FOR DISHWASHER PER ANSI A117.1 SECTION <br />804.5.3. <br />5 ADA CLEAR FLOOR SPACE FOR REFRIGERATOR PER ANSI A117.1 SECTION <br />804.5.6. <br />© ADA CLEAR FLOOR SPACE FOR SINK PER ANSI A117.1. <br />I o <br />Code Notes: <br />Legend: <br />O ALL NEW COUNTERS ARE 34" HIGH PER ICC/ANSI A117.1 SECTION 902. <br />48 UNOBSTRUCTED TURNING SPACE PERMITTED TO INCLUDE KNEE AND TOE <br />CLEARANCE PER ICC/ANSI A117.1 SECTION 304. <br />1. MEANS OF EGRESS ILLUMINATION: THE MEANS OF EGRESS (EXIT PATHWAY) AND THE <br />® EXIT SIGN <br />� <br />EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING IS <br />OCCUPIED AT AN ILLUMINATION LEVEL NOT LESS THAN 1-FOOT CANDLE (10 LUX) <br />MMON ATH EGRE <br />OPOSS TRAVEL F <br />FIRE EXTINGUISHER <br />Q9 ADA CLEAR FLOOR SPACE FOR URINAL PER ANSI A117.1 SECTION 605.3. <br />JURISDICTION STAMP <br />SURFACEAT THE WALK I NG LEVEL PERLIGHTING MUST BE PROVIDED WITH <br />EXIT ACCESS TRAVEL DISTANCE <br />cR CARD READER <br />RBC 1008.3, <br />EMERGENCY BATTERY BACK <br />2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL ENGINEER <br />JXX OCCUPANT LOAD THROUGH OPENING <br />i4 ADA CLEAR FLOOR SPACE FOR LAVATORY PER ANSI A117.1 SECTION <br />606.2.. <br />1 ST FL EXIT PLAN & <br />ACCORDING TO APPLICABLE CODES/ORDINANCES IN JURISDICTION. THE ENGINEER MAY <br />REFERENCE THIS CODE SUMMARY SHEET. HOWEVER, IT SHALL REMAIN THE SOLE <br />EXIT PROTECTED EXIT <br />11 ADA CLEAR FLOOR SPACE FOR TRANSFER TYPE SHOWER PER ANSI <br />Q A117.1 SECTION 608.2.1.2. <br />CODES SUMMARY <br />RESPONSIBILITY OF THE ENGINEER TO COMPLETE A SCOPE OF WORK ADDRESSING ALL <br />OCCUPANCY <br />EGRESS LIGHTING I.E.; ROOMS, SPECIALIZED SPACES, PATHWAYS, ETC. PER THE <br />BROOM USE <br />12 45 MIN FIRE RATED DOOR. GC TO VERIFY EXISTING WALL CONSTRUCTION <br />AFOREMENTIONED CODES. FINAL EGRESS LIGHTING DESIGN SUBJECT TO BUILDING <br />RM AME 101-ROOM NUMBER <br />AND MAINTAIN FIRE RATINGS. <br />OFFICIAL DISCRETION. <br />3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN UNLOCKED <br />200SF ROOM AREA <br />1:150 1.30E OCCUPANT LOAD <br />13 NEW ACCESSIBLE DUAL HEIGHT DRINKING FOUNTAIN AND BOTTLE FILLER <br />DURING AN EVENT/EMERGENCY PER IBC 1010.1.9. <br />OCCUPANT LOAD FACTOR <br />AND CLEARANCE. <br />A <br />GC VERIFY ALL EXISTING CONSTRUCTION IN FIELD FOR RATED <br />4. NON -EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO REMAIN LOCKED <br />FIRE -RATED WALLS <br />_ _ <br />I <br />DURING AN EVENT/EMERGENCY. DOOR CAN STILL BE OPENED WITH A KEY DURING <br />�� <br />DIAMOND QUANTITY INDICATES <br />CONSTRUCTION. <br />RUCTION. ALL NEW CONSTRUCTION (PARTITIONS, DOORS, <br />I <br />SUCH EVENT/EMERGENCY. <br />�S�S- <br />HOURLY RATING. <br />WINDOWS, ETC.) SHALL MAINTAIN FIRE RATINGS IN EXISTING <br />5. FIRE EXTINGUISHERS MUST BE WITHIN A 75' MAXIMUM TRAVEL DISTANCE OF ANY <br />- S S - "S" INDICATES SMOKE PARTITION. <br />CONSTRUCTION. GC TO NOTIFY ARCHITECT OF FIELD CONDITIONS. <br />LOCATION. <br />2023.JPC ARCHITECTS. LLC <br />