Laserfiche WebLink
/,, 2ND FLOOR EXIT PLAN <br />1 . SCALE: 1/16"=1'-0" <br />SEE SHEET 1-0.1 FOR PLUBING <br />CALCULATIONS <br />Code Notes: <br />Legend: <br />1. MEANS OF EGRESS ILLUMINATION: THE MEANS OF EGRESS (EXIT PATHWAY) AND THE <br />- � <br />® EXIT SIGN <br />EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING IS <br />COMMON PATH OF EGRESS TRAVEL <br />OCCUPIED AT AN ILLUMINATION LEVEL NOT LESS THAN 1-FOOT CANDLE (10 LUX) <br />FIRE EXTINGUISHER <br />AT THE WALKING SURFACE LEVEL PER IBC 1008. LIGHTING MUST BE PROVIDED WITH <br />EXIT ACCESS TRAVEL DISTANCE <br />CR CARD READER <br />EMERGENCY BATTERY BACK-UP PER IBC 1008.3. <br />2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL ENGINEER <br />,XX OCCUPANT LOAD THROUGH OPENING <br />ACCORDING TO APPLICABLE CODES/ORDINANCES IN JURISDICTION. THE ENGINEER MAY <br />REFERENCE THIS CODE SUMMARY SHEET. HOWEVER, IT SHALL REMAIN THE SOLE <br />EXIT PROTECTED EXIT <br />RESPONSIBILITY OF THE ENGINEER TO COMPLETE A SCOPE OF WORK ADDRESSING ALL <br />EGRESS LIGHTING I.E.; ROOMS, SPECIALIZED SPACES, PATHWAYS, ETC. PER THE <br />OCCUPANCY <br />AFOREMENTIONED CODES. FINAL EGRESS LIGHTING DESIGN SUBJECT TO BUILDING <br />ROOM USE <br />OFFICIAL DISCRETION. <br />RIM 101-ROOM NUMBER <br />3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN UNLOCKED <br />IV 200SF ROOM AREA <br />DURING AN EVENT/EMERGENCY PER IBC 1010.1.9. <br />1:150 1.30E OCCUPANT LOAD <br />4. NON -EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO REMAIN LOCKED <br />OCCUPANT LOAD FACTOR <br />DURING AN EVENT/EMERGENCY. DOOR CAN STILL BE OPENED WITH A KEY DURING <br />SUCH EVENT/EMERGENCY. <br />5. FIRE EXTINGUISHERS MUST BE WITHIN A 75' MAXIMUM TRAVEL DISTANCE OF ANY <br />FIRE RATED WALLS <br />LOCATION. <br />----- O-S--------- #-S- DIAMOND QUANTITY <br />HOURLY RATING. <br />INDICATES <br />- S S - "S" INDICATES SMOKE PARTITION. <br />Code Calculations: <br />N <br />1. REQUIRED EGRESS WIDTH: <br />1.1. EGRESS WIDTHS REQUIRED PER IBC 1005.3.1 & 1005.3.2: <br />1.2. STAIRS: 0.3"/000UPANT <br />1.3. OTHER COMPONENTS: 0.2"/OCCUPANT <br />2. MAXIMUM OCCUPANT LOAD LIMITED BY STAIRWAYS: <br />AREA A. 48- (TOTAL STAIR WIDTH) / 0.3 = 160 MAXIMUM OCCUPANTS <br />AREA B: 96" (TOTAL STAIR WIDTH) / 0.3 = 320 MAXIMUM OCCUPANTS <br />W <br />3. MAXIMUM OCCUPANT LOAD LIMITED BY OTHER EGRESS COMPONENTS: <br />N/A <br />4. (2) MINIMUM EXITS REQUIRED PER IBC 1006.2.1/1006.3.2. <br />(2) EXITS HAVE BEEN PROVIDED. <br />O <br />5. ALL CONFERENCE ROOMS UNDER 50 OCCUPANTS (OR 750 SF) TO BE <br />N <br />CONSIDERED B OCCUPANCY PER IBC 303.1.2. <br />7 <br />to <br />6. "COMMON PATH OF EGRESS TRAVEL" FOR B OCCUPANCY TO BE <br />U.I <br />Z <br />100'-0- OR LESS (75'-0" WITHOUT OR SPRINKLERS THROUGHOUT <br />O <br />BLDG) AS ALLOWED PER IBC TABLE 1006.2.1. <br />\` <br />c 00 <br />7. "EXIT ACCESS TRAVEL DISTANCE" FOR B OCCUPANCY TO BE 300'-0* <br />> <br />OR LESS (200'-0" WITHOUT QR SPRINKLERS THROUGHOUT BLDG) AS <br />Q <br />ALLOWED PER INC TABLE 1017.2. <br />t <br />7.1. EXIT TRAVEL DISTANCE SHALL BE MEASURED TO EXIT DISCHARGE <br />N di <br />OR EXIT STAIR, BUT CONTINUE DOWN A EXIT ACCESS STAIR. <br />8. DEAD-END CORRIDORS TO BE LESS THAN 20'-0". (50'-0" IF FULLY <br />Pp N <br />SPRINKLERED AND B, E, F, OR S OCCUPANCY) PER IBC 1020.4. <br />P m <br />ZAP ENERGY <br />Floor 2 Occupant Load: <br />Opus Seaway <br />Floor 1 & 2 <br />2300 Merrill Creek Pkwy <br />REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR <br />Room <br />Square <br />Load <br />Oxupant <br />Occupancy <br />Room Name <br />Number <br />Footage <br />Factor <br />Load <br />Everett, WA <br />FLOOR 2 AREA B <br />B OPEN OFF 200 3210 150 21.4 <br />B <br />COFFEE <br />201 <br />71 <br />150 <br />0.5 <br />B <br />MEETING <br />204 <br />204 <br />15 <br />13.6 <br />B <br />MEETING <br />205 <br />205 <br />15 <br />13.7 <br />DESIGN JPC <br />DRAWN NB/AG <br />CHECKED TIP <br />NO. 22-0799 <br />B <br />OFFICE <br />206 <br />206 <br />150 <br />1.4 <br />B <br />OFFICE <br />207 <br />113 <br />150 <br />0.8 <br />B <br />OFFICE <br />208 <br />106 <br />150 <br />0.7 <br />B <br />STOP <br />209 <br />89 <br />300 <br />0.3 <br />B <br />MEETING <br />210 <br />338 <br />15 <br />22.5 <br />B <br />STOP <br />211 <br />127 <br />300 <br />0.4 <br />B <br />MEETING <br />212 <br />342 <br />15 <br />22.8 <br />B <br />OPEN OFF <br />213 <br />4236 <br />150 <br />28.2 <br />B <br />SERVER <br />217 <br />248 <br />300 <br />0.8 <br />AREA B <br />TOTAL <br />9,495 <br />TOTAL <br />127 <br />TOTAL <br />AREA: <br />OCC: <br />fi189 REGISTERED <br />FLOOR 2 AREA A <br />B <br />IT <br />221 <br />90 <br />300 <br />0.3 <br />B <br />MEETING <br />221 <br />221 <br />15 <br />14.7 <br />B <br />OPEN OFF <br />225 <br />110 <br />150 <br />0.7 <br />B <br />OFFICE <br />226 <br />110 <br />150 <br />0.7 <br />AREA A <br />TOTAL <br />531 <br />TOTAL <br />TOTAL <br />AREA: <br />OCC: <br />17 <br />ARCHITECT <br />TOTAL <br />TOTAL <br />10,026 <br />TOTAL <br />144 <br />AREA <br />OCC, <br />MARKA'ITERSON <br />STATE OF WASHINGTON <br />02-17-2023 PERMIT SET <br />Key Notes: NOT ALL KEYNOTES ARE USED ON THIS SHEET. <br />Oj NEW OR EXISTING BUILDING STANDARD EXIT LIGHT. GC TO VERIFY <br />EXISTING EXIT LIGHT LOCATIONS AS SHOWN. <br />O2 NEW BUILDING STANDARD FIRE EXTINGUISHER AND CABINET. <br />0 ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. <br />q ADA CLEAR FLOOR SPACE FOR DISHWASHER PER ANSI A117.1 SECTION <br />804.5.3. <br />5 ADA CLEAR FLOOR SPACE FOR REFRIGERATOR PER ANSI A117.1 SECTION <br />804.5.6. <br />© ADA CLEAR FLOOR SPACE FOR SINK PER ANSI A117.1. <br />O ALL NEW COUNTERS ARE 34" HIGH PER ICC/ANSI A117.1 SECTION 902. <br />® UNOBSTRUCTED TURNING SPACE PERMITTED TO INCLUDE KNEE AND TOE <br />CLEARANCE PER ICC/ANSI A117.1 SECTION 304. <br />Q9 ADA CLEAR FLOOR SPACE FOR URINAL PER ANSI A117.1 SECTION 605.3. <br />10 ADA CLEAR FLOOR SPACE FOR LAVATORY PER ANSI A117.1 SECTION <br />606.2.. <br />11 ADA CLEAR FLOOR SPACE FOR TRANSFER TYPE SHOWER PER ANSI <br />A117.1 SECTION 608.2.1.2. <br />ip 45 MIN FIRE RATED DOOR. GC TO VERIFY EXISTING WALL CONSTRUCTION <br />AND MAINTAIN FIRE RATINGS, <br />13 NEW ACCESSIBLE DUAL HEIGHT DRINKING FOUNTAIN AND BOTTLE FILLER <br />AND CLEARANCE. <br />GC TO VERIFY ALL EXISTING CONSTRUCTION IN FIELD FOR RATED <br />CONSTRUCTION. ALL NEW CONSTRUCTION (PARTITIONS, DOORS, <br />WINDOWS, ETC.) SHALL MAINTAIN FIRE RATINGS IN EXISTING <br />CONSTRUCTION. GC TO NOTIFY ARCHITECT OF FIELD CONDITIONS. <br />2ND FL EXIT PLAN & <br />CODES SUMMARY <br />2023.-ARCHITECTS.- <br />