Laserfiche WebLink
T/SHEATHING <br />WINDOW OPENING PER <br />ARCH, 12'-0" MAX <br />3x12 DFL NO. 1 HEADER <br />DR APPROVED EQUAL <br />:3) 16d-SHORT END <br />VAIL TO HEADER, TYP <br />1) KING AND (2) <br />GRIMMER STUDS, TYP <br />3x12 DFL NO. 1 SILL OR <br />4PPROVED EQUAL <br />16d-SHORT @ 16" OC AT <br />GRIMMER STUDS, TYP <br />=X STUD FRAMING <br />-X SILL PLATE <br />T/AHFATHINr <br />(4) 16d-SHORT TOENAIL, TYP <br />NOTES: <br />1. KING AND TRIMMER STUDS TO BE 2x TO MATCH EXISTING WALL FRAMING. <br />2. EXISTING WALL SHEATHING SHOULD EXTEND TO EDGE OF OPENING WITH 16d-SHORT <br />NAILS @ 6" OC ALONG EACH EDGE. <br />3. EXISTING FRAMING SHALL BE SHORED DURING OPENING DEMO UNTIL ALL NEW <br />STRUCTURAL ELEMENTS ARE FULLY INSTALLED. <br />T/SHEATHING <br />WINDOW OPENING PER <br />ARCH, 6'-0" MAX <br />6x8 DFL NO. 1 HEADER <br />OR APPROVED EQUAL — <br />(3) 16d-SHORT END <br />NAIL TO HEADER, TYP - <br />(1) KING AND (2) <br />TRIMMER STUDS, TYP — <br />6x8 DFL NO. 1 SILL OR <br />APPROVED EQUAL <br />16d-SHORT @ 16" OC AT <br />TRIMMER STUDS, TYP — <br />EX STUD FRAMI NO <br />EX SILL PLATE <br />T/SHEATHING II H41 <br />(4) 16d-SHORT TOENAIL, TYP <br />NOTES: <br />1. KING AND TRIMMER STUDS TO BE 2x TO MATCH EXISTING WALL FRAMING. <br />2. EXISTING WALL SHEATHING SHOULD EXTEND TO EDGE OF OPENING WITH 16d-SHORT <br />NAILS @ 6" OC ALONG EACH EDGE. <br />3. EXISTING FRAMING SHALL BE SHORED DURING OPENING DEMO UNTIL ALL NEW <br />STRUCTURAL ELEMENTS ARE FULLY INSTALLED. <br />HEADER AND SILL AT NEW WINDOW OPENING HEADER AND SILL AT NEW WINDOW OPENING <br />1 0 1 /2" = V-0" 11 1 /2„ = 1'-0" <br />(4) 16d-SHORT TOENAIL, TYP <br />NOTES: <br />1. KING AND TRIMMER STUDS TO BE 2x TO MATCH EXISTING WALL FRAMING. <br />2. EXISTING WALL SHEATHING SHOULD EXTEND TO EDGE OF OPENING WITH 16d-SHORT <br />NAILS @ 6" OC ALONG EACH EDGE. <br />3. EXISTING FRAMING SHALL BE SHORED DURING OPENING DEMO UNTIL ALL NEW <br />STRUCTURAL ELEMENTS ARE FULLY INSTALLED. <br />T/SHEATHING <br />WINDOW OPENING PER <br />ARCH, 6'-0" MAX <br />6x8 DFL NO. 1 HEADER <br />OR APPROVED EQUAL — <br />(3) 16d-SHORT END <br />NAIL TO HEADER, TYP - <br />(1) KING AND (2) <br />TRIMMER STUDS, TYP — <br />6x8 DFL NO. 1 SILL OR <br />APPROVED EQUAL <br />16d-SHORT @ 16" OC AT <br />TRIMMER STUDS, TYP — <br />EX STUD FRAMI NO <br />EX SILL PLATE <br />T/SHEATHING II H41 <br />(4) 16d-SHORT TOENAIL, TYP <br />NOTES: <br />1. KING AND TRIMMER STUDS TO BE 2x TO MATCH EXISTING WALL FRAMING. <br />2. EXISTING WALL SHEATHING SHOULD EXTEND TO EDGE OF OPENING WITH 16d-SHORT <br />NAILS @ 6" OC ALONG EACH EDGE. <br />3. EXISTING FRAMING SHALL BE SHORED DURING OPENING DEMO UNTIL ALL NEW <br />STRUCTURAL ELEMENTS ARE FULLY INSTALLED. <br />HEADER AND SILL AT NEW WINDOW OPENING HEADER AND SILL AT NEW WINDOW OPENING <br />1 0 1 /2" = V-0" 11 1 /2„ = 1'-0" <br />U <br />LLJ <br />U <br />.Q <br />c <br />LU O <br />Q <br />Z. <br />U <br />Qa <br />s� <br />C <br />N � <br />_J <br />0 N <br />0 m <br />ZAP ENERGY <br />Opus Seaway <br />Floor 1 & 2 <br />2300 Merrill Creek Pkwy <br />Everett. WA <br />DESIGN: <br />DRAWN: <br />CHECKED: <br />NO.: 2300091 <br />WAYNE <br />WASy� o�I� <br />c <br />m 4' <br />Pp ''Pp 48649 ti41 <br />F�SSI A �{1G1} <br />tiI\^I"V <br />ANo Issue DesCNutIon Date <br />PERMIT SET 02-17-2023 <br />WALL OPENING DETAILS <br />S-3.5 <br />