SHEET No. <br />DESCRIPTION <br />FA-01 <br />SYSTEM INFORMATION <br />FA-02 <br />TYPICAL WIRING AND MOUNTING DETAILS <br />FA03 <br />SYSTEM CALCULATIONS <br />FA-04 <br />FLOOR 1 AREA A & B - FIRE ALARM PLAN <br />FA-05 <br />FLOOR 2 AREA A & B FIRE ALARM PLAN <br />FA-06 <br />RISER DIAGRAM <br />SHEETINDEX <br />MODIFICATIONS OF NEW FIRE ALARM PANEL WITH NEW NOTIFICATION AND <br />ADDRESSABLE DEVICES. <br />SCOPE OF WORK <br />WIRE SCHEDULE AND CONDUIT FILL CHART <br />WIRE DESIGNATION <br />SYMBOL <br />DESCRIPTION <br />NUMBER <br />OF CONDUCTORS SIZE <br />TYPE <br />COLOR CODE <br />D <br />DATA LINE - ADDRESSABLE <br />LOOP <br />TWISTED <br />PAIR WITH SHIELD #16 <br />FPLP <br />S <br />STROBE CIRCUIT <br />TWO <br />#14 <br />FPLP <br />I <br />INITIATION CIRCUIT <br />TWO <br />#16 <br />FPLP <br />T <br />POWER SUPPLY TRIGGER <br />TWO <br />#14 <br />FPLP <br />A <br />ANNUNCIATOR NETWORK <br />TWISTED <br />PAIR WITH SHIELD #16 <br />FPLP <br />P-LINK <br />P-LINK <br />FOUR <br />#16 <br />FPLP <br />CONDUIT <br />FILL CHART <br />NO. OF CONDUCTORS <br />VOLTS <br />WIRE SIZE <br />TYPE DIMENSIONS <br />AREA <br />TWO <br />600V <br />#12 AWG <br />THHN/THWN .244 <br />O.D. <br />.0467 <br />TWO <br />600V <br />#14 AWG <br />THHN/THWN TWISTED .210 <br />O.D. <br />.0346 <br />TWO CONDUCTOR <br />300V <br />#18 AWG <br />FPL TW CABLE .156 <br />O.D. <br />.0191 <br />CONDUIT FILL <br />CALCULATE THE <br />TOTAL AREA OF THE WIRE <br />BEING RUN IN THE CONDUIT <br />FROM <br />THE TABLE <br />ABOVE. CHOOSE <br />THE SIZE <br />OF CONDUIT <br />BASED ON THE MAXIMUM FILL <br />DIMENSION <br />FROM <br />THE TABLE BELOW <br />THAT DOES <br />NOT EXCEED THE TOTAL AREA OF THE <br />WIRE. <br />CONDUIT SIZE <br />MAXIMUM FILL <br />1/2" <br />.12 SQUARE INCH <br />3/4" <br />.21 SQUARE INCH <br />1,, <br />.34 SQUARE INCH <br />1-1/4" <br />.60 SQUARE INCH <br />1-1 2" <br />.82 SQUARE INCH <br />2' <br />1.34 SQUARE INCH <br />ZAP <br />FIRE ALARM SYSTEM <br />EVERETT, WASHINGTON <br />FOR POTTER SYSTEM: <br />DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED <br />WITH DEVICES ADDRESS. <br />1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS <br />DEVICE 1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. <br />2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. <br />3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL <br />BRANCHING IS PERMISSIBLE <br />4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL <br />ELECTRIC CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. <br />5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, <br />STANDARD BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) <br />ARE NOT SUPPLIED BY GUARDIAN SECURITY SYSTEMS. <br />6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT <br />AIR STREAM OF AIR SUPPLY OUTLETS. PER NFPA 72 2-3.5.1 <br />7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE, & OR CABLE TRAY, <br />TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY, <br />AND UNIQUELY MARKED FOR FUTURE IDENTIFICATION. <br />8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED <br />DRAWINGS FOR "AS BUILT" PURPOSES. <br />9. FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT <br />SHEETS AND/OR INSTALLATION INSTRUCTIONS. <br />10. THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS <br />MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, <br />SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER <br />SOURCES.120voc POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL WITHOUT <br />DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. <br />11. ALL HORN/STROBE AND STROBE DEVICES SHALL BE MOUNTED AT A HEIGHT <br />OF 80" A.F.F. OR 6' BELOW DROPPED CEILING, WHICHEVER IS LESS. <br />12. ALL MANUAL PULL STATIONS SHALL BE MOUNTED AT 48" A.F.F. TO THE <br />ACTIVATION DEVICE. <br />13. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. <br />14. PER NFPA 72 SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER <br />THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPLETE AND FINAL. <br />EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION <br />FOR PROTECTION DURING CONSTRUCTION. <br />DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL <br />TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH NFPA 72 <br />CHAPTER 7. <br />15. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT <br />AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR <br />OTHER BACK BOXES OF DIFFERENT CIRCUITS. <br />16, ALL WIRING SHALL BE METERED, VERIFIED TO BE CONTINUOUS, FREE OF GROUND <br />AND FREE OF SHORTS BETWEEN CONDUCTORS AND OTHER CIRCUITS PRIOR TO <br />FINAL EQUIPMENT TRIM. <br />17. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A <br />PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACE. <br />18. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE <br />OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES <br />AFTER COMPLETION OF THEIR INSTALLATION. <br />19. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH <br />IT IS LOCATED. <br />20. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. <br />QUANTITY <br />SYMBOL <br />DESCRIPTION <br />MODEL <br />MANUFACTURER <br />BACKBOX <br />MOUNTING HEIGHT <br />1 <br />FACP <br />FIRE ALLRPANEL <br />AFC-100 <br />POTTER <br />PROVIDED <br />F.F. <br />CONREMOTE <br />TO TOP <br />1 <br />FAA <br />RA-6500FR <br />POTTER <br />EXISTING <br />66" A.F.F. <br />E <br />ANNUNCIATOR <br />TO TOP <br />1 <br />BPS <br />BOOSTER REMOTE <br />PSN-106 <br />POTTER <br />PROVIDED <br />66" A.F.F. <br />POWER SUPPLY <br />TO TOP <br />4 <br />® <br />SMOKE DETECTOR <br />PAD100-PD W/ <br />POTTER <br />4S DEEP <br />CEILING <br />(ADDRESSABLE -PHOTO) <br />PAD100-6DB BASE <br />W/ 1G RING <br />❑F <br />MANUAL PULL STATION <br />PAD100-PSDA <br />POTTER <br />D <br />1 <br />(ADDRESSABLE) <br />W/ 1G RING <br />TO CENTER <br />[flE <br />MANUAL PULL STATION <br />PAD100-PSDA <br />POTTER <br />4S DEEP <br />48" A.F.F. <br />1 <br />(ADDRESSABLE) <br />W/ 1G RING <br />TO CENTER <br />SINGLE INPUT <br />RLY-5 <br />POTTER <br />AE-2 BOX <br />VERIFY LOCATION <br />1 <br />RLY <br />INTERFACE MODULE <br />IN FIELD <br />DUAL INPUT <br />PAD100-DM <br />POTTER <br />4S BOX <br />VERIFY LOCATION <br />5 <br />DM <br />INTERFACE MODULE <br />IN FIELD <br />1 <br />FIRE ALARM <br />ELST <br />WHEELOCK <br />4S BOX <br />80" A.F.F. <br />--ISLE <br />STROBE <br />TO BOTOM <br />Y <br />FIRE ALARM <br />ELHSW <br />WHEELOCK <br />4S BOX <br />80" A.F.F. <br />2 <br />LJE <br />HORN STROBE <br />TO BOTOM <br />FIRE ALARM <br />ELHSWC <br />WHEELOCK <br />4S BOX <br />CEILING <br />26 <br />HORN STROBE <br />17 <br />{ } <br />FIRE ALARM <br />ELSTC <br />WHEELOCK <br />4S BOX <br />CEILING <br />l <br />STROBE <br />JUNCTION <br />F.B.O. <br />F.B.O. <br />N/A <br />VERIFY LOCATION <br />--- <br />BOX <br />IN FIELD <br />J <br />END -OF -LINE <br />VERIFY LOCATION <br />RESISTOR <br />IN FIELD <br />ABOVE FINISHED <br />N/A <br />N/A <br />N/A <br />N/A <br />--- <br />A.F.F. <br />FLOOR <br />--- <br />F.B.O. <br />FURNISHED BY <br />N/A <br />N/A <br />N/A <br />N/A <br />OTHERS <br />--- <br />N/A <br />NOT <br />N/A <br />N/A <br />N/A <br />N/A <br />APPLICABLE <br />--- <br />RED <br />AS BUILT <br />N/A <br />N/A <br />N/A <br />ADD OR CHANGE <br />- - - <br />GREEN <br />AS BUILT <br />N/A <br />N/A <br />N/A <br />REMOVE <br />--- <br />BLUE <br />AS BUILT <br />NOTES TO CAD <br />N/A <br />N/A <br />N/A <br />Z <br />0 <br />I <br />C� <br />�M C <br />Qo <br />N <br />W <br />� ErZ <br />W a0 <br />Y a <br />WZ 0 <br />g "a LL <br />J <br />a �� <br />W Oc k <br />oC W W <br />LL �c C <br />M W J <br />ILW <br />Irn <br />V/ <br />SCALE: NOT TO SCALE <br />P.GUPTA <br />AARON E.MAUS <br />DESIGNED BY: <br />NICET LEVEL III <br />L. ALLEN <br />CERT. #133903 EXP. 03/01 /2024 <br />DATE:03 :03/ 24 23 <br />BACKROUND PLAN PROVIDED <br />JOB NUMBER:69447-1 <br />Z>YIVIOLJL7 LtlatlNU FA-01 <br />& Confidential. Coovriaht 2012 by Guardian Securitv Svstems. Inc. All Riahts Reserved <br />