O <br /> I. FUEL BURNING APPLIANCES LOCATED' WITHIN THE BUILDING ENVELOPE SHALL TABLE 3-2 0 _ y o,w <br /> OBTAIN AIR FROM OUTDOORS, MEETING THE PROVISIONS OF THE IBC/IRC. VENTILATION RATES FOR ALL GROUP R OCCUPANCIES FOUR STORIES AND LESS* 6 woo o�w�� <br /> MINIMUM AND MAXIMUM VENTILATION RATES: CUBIC FEET PER MINUTE (CFM) 6 pw 026,% <br /> 2. FUEL BURNING APPLIANCES LOCATED OUTSIDE THE BUILDING ENVELOPE SHALL MEET THE 22ME w <br /> PROVISIONS OF THE IBC/IRC. FLOOR BEDROOMS �° UW3°"'518W3p <br /> yw ��w�^a�°n8poi <br /> AREA,FT 2 OR LESS 3 4 5 6 7 8 a> = wN=d�y2o <br /> 3. DUCTWORK LOCATION AND SOURCE OF COMBUSTION AIR SHALL MEET THE PROVISIONS OF MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. MIN. MAX. Z Son i <br /> THE IBC/IRC. o W o>wok3wt5�> <br /> <500 50 75 65 98 80 120 95 143 110 165 125 188 140 210 "° y� N�,E t5 m <br /> © MIXF.EM <br /> 501-1000 55 83 70 105 85 128 100 150 115 173 130 195 145 218 <br /> ALL WARM AIR FURNACES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND 1001-1500 60 90 75 113 90 135 105 158 120 180 135 203 150 225 - 0 <br /> INSTALLED PER THE IBC/IRC. 1501-2000 65 98 80 120 95 143 110 165 125 188 140 210 155 233 <br /> 2001-2500 70 105 85 128 100 150 115 173 130 195 145 218 160 240 <br /> APPLIANCES INTENDED FOR INSTALLATION IN CLOSETS, ALCOVES OR CONFINED SPACES SHALL 2501-3000 75 113 90 135 105 158 120 180 135 203 150 225 165 248 <br /> BE SO LISTED AND INSTALLED PER THE IBC/IRC. <br /> 3001-3500 80 120 95 143 110 165 125 188 140 210 155 233 170 255 U <br /> NO WARM AIR FURNACE SHALL BE INSTALLED IN A ROOM USED OR DESIGNED TO BE USED 3501-4000 85 128 100 150 115 173 130 195 145 218 160 240 175 263 y <br /> AS A BEDROOM, BATHROOM, CLOSET OR IN ANY ENCLOSED SPACE WITH ACCESS ONLY 4001-5000 95 143 110 165 125 188 140 210 155 233 170 255 185 278 ti w Ol <br /> THROUGH SUCH ROOM OR SPACE, EXCEPT DIRECT VENT FURNACE, ENCLOSED FURNACES AND 5001-6000 105 158 120 180 135 203 150 225 165 248 180 270 195 293 I NI <br /> ELECTRIC HEATING FURNACES PER THE IBC/IRC. 6001-7000 115 173 130 195 145 218 160 240 175 263 190 285 205 308 S S <br /> 7001-8000 125 188 140 210 155 233 170 255 185 278 200 300 215 323 <br /> NO WARM AIR FURNACE SHALL BE INSTALLED IN A CLOSET OR ALCOVE WITH A SPACE LESS 8001-9000 135 203 150 225 165 248 180 270 195 293 210 315 225 338 c <br /> THAN 12" WIDER THAN THE FURNACE OR A CLEARANCE OF 3" ALONG THE SIDES, BACK AND >9000 145 218 160 240 175 263 190 285 205 308 220 330 235 353 <br /> TOP ACCORDING TO THE IBC/IRC. * FOR RESIDENCES THAT EXCEED S BEDROOMS, INCREASE THE MINIMUM REQUIREMENT LISTED N <br /> FOR S BEDROOMS BY AN ADDITIONAL 15 CFM PER BEDROOM. THE MAXIMUM CFM IS EQUAL p N <br /> LIQUEFIED PETROLEUM GAS BURNING APPLIANCES SHALL NOT BE INSTALLED IN A PIT, TO I. TIMES THE MINIMUM. O U <br /> BASEMENT OR SIMILAR LOCATION WHERE HEAVIER THAN AIR GASES MIGHT COLLECT. • <br /> APPLIANCES SO FUELED SHALL NOT BE INSTALLED IN AN ABOVE GRADE UNDER FLOOR TABLE 3-3 % <br /> SPACE OR BASEMENT UNLESS SUCH LOCATION IS PROVIDED WITH AN APPROVED MEANS FOR PRESCRIPTIVE EXHAUST DUCT SIZING • \ <br /> REMOVAL OF UNBURNED GAS PER THE IBC/IRC. FAN TESTED MINIMUM MAXIMUM MINIMUM MAXIMUM MAXIMUM V Cp�� 0 <br /> CFM FLEX LENGTH SMOOTH LENGTH ELBOWS <br /> HEATING AND COOLING APPLIANCES LOCATED IN A GARAGE AND WHICH GENERATE A GLOW, • a Q <br /> SPARK OR FLAME CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE INSTALLED WITH @ 0.25"W.G. DIAMETER FEET DIAMETER FEET 1 <br /> THE PILOTS AND BURNERS OR HEATING ELEMENTS AND SWITCHES AT LEAST 15" ABOVE THE 50 4 INCH 25-0" 4 INCH 70'-0" 3 ° <br /> FLOOR SURFACE. 50 5 INCH 90.-0" 5 INCH 100'-0" 3 1 <br /> 50 6 INCH NO LIMIT 6 INCH NO LIMIT 3 v c <br /> FIRE DAMPERS NEED NOT BE INSTALLED IN AIR DUCTS PASSING THROUGH THE WALL, FLOOR 80 4 INCH 2 N/A 4 INCH 20'-0" 3 1114 <br /> OR CEILING SEPARATING A RESIDENCE (GROUP B, DIVISION 3 OCCUPANCY)FROM A GARAGE 80 5 INCH 15'-0" 5 INCH 100'-0" 3 <br /> (GROUP M, DIVISION 1 OCCUPANCY), PROVIDED SUCH DUCTS WITHIN THE GARAGE ARE 80 6 INCH 90'-0" 6 INCH NO LIMIT 3 <br /> CONSTRUCTED OF STEEL HAVING A THICKNESS NOT LESS THAN 0.019" (NO. 26 GALVANIZED 100 5 INCH 2 N/A 5 INCH 50'-0" 3 <br /> SHEET GAUGE) AND HAVE NO OPENINGS INTO THE GARAGE PER THE IBC/IRC. 100 6 INCH 45-0" 6 INCH NO LIMIT 3 <br /> 125 6 INCH 15'-0" 6 INCH NO LIMIT 3 <br /> WARM AIR FURNACE INSTALLATIONS IN ATTICS OR CRAWL SPACES SHALL COMPLY WITH THE 125 7 INCH 70'-0" 7 INCH NO LIMIT 3 <br /> IBC/IRC. <br /> NOTE: 1. FOR EACH ADDITIONAL ELBOW SUBTRACT 10'-0" FROM LENGTH. Z <br /> EVERY APPLIANCE DESIGNED TO BE VENTED SHALL BE CONNECTED TO A VENTING SYSTEM 2. <br /> FLEX DUCTS OF THIS DIAMETER ARE NOT PERMITTED WITH FANS OF THIS SIZE. <br /> COMPLYING WITH THE IBC/IRC. g <br /> TABLE 3-5 W <br /> L EVERY FACTORY BUILT CHIMNEY, TYPE VENT, TYPE B GAS VENT OT TYPE BW GAS VENT PRESCRIPTIVE INTEGRATED FORGED AIR SUPPLY DUCT SIZINGZ <br /> SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF ITS LISTING, MANUFACTURERS <br /> INSTALLATION INSTRUCTIONS AND THE REQUIREMENTS OF THE IBC/IRC. REQUIRED FLOW (CFM) MINIMUM SMOOTH MINIMUM FLEXIBLEMAXIMUM LENGTH MAXIMUM NUMBER <br /> PER TABLE 3-2 DUCT DIAMETER DUCT DIAMETER I OF ELBOWS 2 <br /> A TYPE B OR BUJ Cc AS VENT SHALL TERMINATE PER THE IBC/IRC. 50-50 6 INCH 1 INCH 20'-0° 3 <br /> 50-125 1 INCH S INCH 20'-0" 3 <br /> A TYPE L VENTING SYSTEM SHALL TERMINATE NOT LESS THAN 2'-0" ABOVE THE HIGHEST 115-115 S INCH 10 INCH 20'-0" 3 <br /> POINT WHERE THE VENT PASSES THROUGH THE ROOF OF THE BUILDING AND AT LEAST 2'-0" 110-240 9 INCH II INCH 20'-0" 3 V <br /> HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10'-0" OF THE VENT PER THE IBC/IRC. <br /> 08 <br /> NOTE: 1. FOR LENGTHS OVER 20 FEET INCREASE DUCT DIAMETER I INCH. (NI <br /> VENT CONNECTORS SHALL BE INSTALLED WITHIN THE SPACE OR AREA IN WHICH THE 2. FOR ELBOWS NUMBERING MORE THAN 3 INCREASE DUCT DIAMETER I INCH X <br /> APPLIANCE IS LOCATED AND SHALL SE CONNECTED TO A CHIMNEY OR VENT IN SUCH A CITY OF EVERETT c„ o <br /> M <br /> MANNER AS TO MAINTAIN THE CLEARANCE TO COMBUSTIBLES PER THE IBC/IRC. REVIEWED FOR PERM ? <br /> FIREPLACES <br /> HEATING EQUIPMENT c ALL MASONRY FIREPLACES AND CHIMNEYS SHALL E3E CONSTRUCTED TO ;Z +,; c <br /> ALL HEATING EQUIPMENT SHALL MEET THE REQUIREMENTS OF THE 1981 NATIONAL APPLIANCE <br /> c. <br /> ENERGY CONSERVATION ACT (NAECA)AND BE SO LABELED. EQUIPMENT SHALL ALSO COMPLY WITH CONPORI"I TO ALL AP 'L[CABLE: PORTIONS OF Ta--IE: IE'O/IRC k cu © <br /> CODE. FLUE LINER MINIMUM, 5/8" FIRE CLAY (OR EQUIVALENT) PER IRC. -1-4 r-1 N <br /> SECTION 1411 OF THE W_SE.C. FLUE AREA PER IRC. CHIMNEYS SHALL SUPPORT ONLY THEIR OWN WEIGHT UNLESS ' d0 S- <br /> HVAC EQUIPMENT FOR LOW-RISE RESIDENTIAL SHALL BE SIZED NO GREATER THAN 150% OF <br /> SPECIFICALLY DESIGNED TO SUPPORT ADDITIONAL LOADS. ALL FIREPLACES SHALL BE w <br /> DESIGN LOAD PROVIDED WITH TIGHTLY FITTING FLUE DAMPERS, OPERATED WITH A READILY ACCESSIBLE Date Jan.21 2020 >, <br /> MANUAL OR APPROVED AUTOMATIC CONTROL, AND AN OUTSIDE SOURCE OF COMBUSTION AIR. Drawn By: JMP <br /> DUCTWORK MINIMUM DUCT SIZE OF 6" SQUARE INCHES IN AREA PROVIDED WITH READILY ACCESSIBLE Sheet Number H <br /> DAMPER LOCATED IN FRONT PART OF FIREBOX. PREFABRICATED FIREPLACES, CHIMNEYS, }� <br /> 1. DUCT SYSTEMS OR FACTORY BUILT AIR DUCTS SHALL BE OF METAL AS SET FORTH BY AND RELATED COMPONENTS TO BEAR U.L. OR I.C.B.O. SEAL OF APPROVAL AND TO BE A <br /> THE IBC/IRC. INSTALLED PER MANUFACTURER'S SPECIFICATIONS. HEARTHS SHALL EXTEND 20" (MIN.) IN <br />
The URL can be used to link to this page
Your browser does not support the video tag.