My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8810 EMERSON PL 2023-09-26
>
Address Records
>
EMERSON PL
>
8810
>
8810 EMERSON PL 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 11:08:29 AM
Creation date
9/6/2023 8:51:57 AM
Metadata
Fields
Template:
Address Document
Street Name
EMERSON PL
Street Number
8810
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0. who way <br /> 0 <br /> DOOqg <br /> '�S WINDOWS AND SKYLIGHTS WHOLE HOUSE VENTILATION z pp= <br /> 0 oN= <br /> 9 00 wr2226 8 <br /> NW CCUw'Q5 = <br /> . F = N =2Sz <br /> GENERAL mrr ' 2wV <br /> DOORS TO THE EXTERIOR MAY HAVE A MAXIMUM 7-3/4" STEP TO A MINIMUM 36." DEEP LANDING. SPECIFICATIONS FROM THE WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY 8o W=wwlsmz <br /> ALL GLAZING SHALL MEET THE REQUIREMENTS OF THE W.S.E.C. TABLE 6-I UNLESS NOTED OTHERWISE. CODE (VIAQ). © LiWio<po <br /> ALL SKYLIGHTS AND SKYWALLS SHALL HAVE LAMINATED GLASS UNLESS NOTED OTHERWISE. yN <br /> SOURCE SPECIFIC VENTILATION REQUIREMENTS. <br /> ALL BEDROOM EMERGENCY EGRESS WINDOWS SHALL HAVE A MINIMUM NET CLEAR OPENING <br /> 1. MINIMUM EXHAUST FAN REQUIREMENTS: CIO rki <br /> 01 <br /> OF 5.7 SQUARE FEET. MINIMUM NET CLEAR OPEN ABLE WIDTH OF 20" AND A MINIMUM NET A. BATHROOMS, LAUNDRIES AND POWDER ROOMS - 50 CFM a 0.25" WG <br /> B. KITCHENS - 100 CFM a 0.25" W.G. (RANGE HOOD OR DOWN DRAFT EXHAUST FAN <br /> CLEAR OPENING HEIGHT OF 24", MAXIMUM FINISHED SILL HEIGHT OF 44" ABOVE FLOOR. <br /> RATED AT MIN. 100 CFM a 0.10" W.G. MAY BE USED FOR EXHAUST FAN REQUIREMENTS.) U i <br /> 2. EXHAUST DUCT REQUIREMENTS: - <br /> ALL FACTORY BUILT WINDOWS TO BE CONSTRUCTED TO PERMIT MAXIMUM INFILTRATION OF ti Q, <br /> 0.5 CFM PER LINEAL FOOT OF OPERABLE SASH PERIMETER AS TESTED BY STANDARD A. INSULATE TO R-4 (MIN.) IN UNCONDITIONED SPACES. kl)N <br /> B. EQUIP WITH A BACK DRAFT DAMPER. Q1 <br /> ASTM E 283.73. SITE BUILT AND MILLWORK SHOP BUILT WOODEN SASH ARE EXEMPT FROM C. TERMINATE OUTSIDE THE BUILDING. 11 S S <br /> INFILTRATION CRITERIA ABOVE, BUT SHALL BE MADE WEATHER-STRIPPED, CAULKED AND 'sF N <br /> BE MADE TIGHTLY FITTING. SLIDING GLASS DOORS TO PERMIT MAXIMUM INFILTRATION OF D. COMPLY WITH TABLE 3-3 ON THIS SHEET. �� <br /> 0.5 CFM PER SQUARE FOOT OF DOOR AREA. PRESCRIPTIVE REQUIREMENTS FOR: OPTION 2. INTERMITTENT WHOLE HOUSE VENTILATION N <br /> INTEGRATED WITH A FORCED AIR SYSTEM (VIAQ 303.4.2): (� Ql <br /> SEE PLANS FOR: "ti N S <br /> 1. MAXIMUM GLAZING AREA. NOTE: WITH THIS OPTION A WHOLE HOUSE FAN IS NOT REQUIRED. Z (N' N <br /> 41 2. GLAZING MANUFACTURER AND MODEL NUMBERS. 1. OUTDOOR AIR SHALL SE SUPPLIED TO ALL HABITABLE ROOMS THROUGH THE FORCED AIR O U <br /> 3. WEIGHTED UA CALCULATIONS FOR SUBSTANDARD GLAZING. RI <br /> SYSTEM DUCTS AT THE RATE SPECIFIED IN TABLE 3-2 ON THIS SHEET. ' (�`I <br /> SAFETY GLAZING LOCATIONS PER IBC/IRC. 2. OUTDOOR AIR INLET DUCT SHALL COMPLY WITH THE FOLLOWING: I 0 <br /> 1. INGRESS AND EGRESS DOORS. A. SIZE ACCORDING TO TABLE 3-5 ON THIS SHEET. ' r <br /> 2. SLIDING GLASS DOORS AND SWINGING GLASS DOORS. B. DUCT FROM A TERMINAL ELEMENT ON THE OUTSIDE OF THE BUILDING TO THE RETURN AIR PLENUM, • lnnl <br /> 3. SHOWER AND BATHTUB ENCLOSURES. AT A POINT WITHIN FOUR FEET UPSTREAM OF THE AIR HANDLER. <br /> 4. GLAZING WITH THE EXPOSED EDGE WITHIN A 24" RADIUS ARC OF EITHER VERTICAL EDGE C. INSULATE TO R-4 (MIN.) WHEN LOCATED WITHIN CONDITIONED SPACES. <br /> OF A DOOR IN THE CLOSED POSITION AND THE BOTTOM EDGE IS LESS THAN 60" ABOVE v Ill <br /> "1 <br /> THE WALKING SURFACE. 3. OUTDOOR AIR INLETS: \p <br /> 5. GLAZING GREATER THAN 9 SQUARE FEET THAT IS LESS THAN IS" ABOVE FINISHED FLOOR. A. PROTECT FROM THE ENTRY OF INSECTS, LEAVES AND OTHER FOREIGN MATERIAL. 114 Q q <br /> 6. GLAZING IN ALL GUARD RAILS. B. LOCATE SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: <br /> I. WITHIN TEN FEET OF AN APPLIANCE VENT OUTLET, UNLESS THE VENT OUTLET IS THREE G <br /> SCREENS NEED NOT SE PROVIDED AT SKYLIGHTS WHEN FULLY TEMPERED GLASS IS USED AS FEET ABOVE THE OUTDOOR AIR INLET. 00 <br /> SINGLE GLAZING OR IN ALL PANES INSULATING UNIT AND ALL OF THE FOLLOWING CONDITIONS ARE MET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. W <br /> 1. THE GLAZING AREA DOES NOT EXCEED IS SQUARE FEET. 3. A HAZARDOUS OR UNSANITARY LOCATION. <br /> 2. THE HIGHEST POINT OF GLASS IS NOT MORE THAN 12'-0" ABOVE ANY WALKING SURFACE OR 4, A ROOM OR SPACE HAVING FUEL BURNING APPLIANCES THEREIN. ® rz <br /> ACCESSIBLE AREA. 5. CLOSER THAN TEN FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM Z, b b <br /> 3. THE NOMINAL THICKNESS OF EACH PANE DOES NOT EXCEED 3/16", UNLESS THE VENT OPENING IS AT LEAST THREE FEET ABOVE THE AIR INLET. �' <br /> 6. ATTICS, CRAWL SPACES OR GARAGES. <br /> MECHANICAL 4. THE OUTDOOR AIR INLET DUCT SHALL SE EQUIPPED WITH ONE OF THE FOLLOWING: Pj 00 z <br /> A. A MOTORIZED DAMPER CONNECTED TO THE AUTOMATIC VENTILATION CONTROL TIMER. Z <br /> GENERAL B. A DAMPER INSTALLED AND SET TO MEET MINIMUM FLOW RATES AS SPECIFIED <br /> IN TABLE 3-2 ON THIS SHEET, BY EITHER FIELD TESTING OR FOLLOWING MANUFACTURER'S L <br /> SOLID FUEL BURNING APPLIANCES INCLUDE AIRTIGHT STOVES, FIREPLACE STOVES, ROOM INSTALLATION INSTRUCTIONS BASED ON SITE CONDITIONS. Q <br /> HEATERS, FACTORY BUILT FIREPLACES AND FIREPLACE INSERTS. ALL SOLID FUEL C. AN AUTOMATIC FLOW REGULATED DEVICE WITH FIELD MEASURED OR FIELD CALCULATED <br /> BURNING APPLIANCES SHALL COMPLY WITH THE PROVISIONS OF THE INTERNATIONAL MINIMUM NEGATIVE PRESSURE OF 0.01" WATER GAUGE AT THE POINT WHERE THE OUTSIDE <br /> RESIDENTIAL CODE. AIR DUCT IS CONNECTED TO THE RETURN AIR PLENUM. N <br /> pp <br /> 5. THE WHOLE HOUSE VENTILATION SYSTEM SHALL SE CONTROLLED BY A 24-HOUR CLOCK VO <br /> HEATING TIMER WITH THE CAPABILITY OF CONTINUOUS OPERATION, MANUAL AND AUTOMATIC O%O <br /> EACH DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING CONTROL. THIS CONTROL WILL CONTROL THE FORCED AIR SYSTEM SLOWER AND IF APPLICABLE - <br /> A TEMPERATURE OF 10 DEGREES FAHRENHEIT AT A HEIGHT OF 3'-0" ABOVE THE FLOOR IN THE AUTOMATIC DAMPER. THE 24-HOUR TIMER SHALL BE READILY ACCESSIBLE. 4 O <br /> ALL HABITABLE ROOMS WHEN THE OUTSIDE TEMPERATURE IS AS SET FORTH IN THE W.S.E.C, THE 24-HOUR TIMER SHALL BE CAPABLE OF OPERATING THE WHOLE HOUSE VENTILATION <br /> SYSTEM WITHOUT ENERGIZING OTHER ENERGY-CONSUMING APPLIANCES. AT THE TIME "—, <br /> DEFINITION OF BUILDING ENVELOPE FROM THE WASHINGTON STATE ENERGY CODE: OF FINAL INSPECTION, THE AUTOMATIC CONTROL TIMER SHALL BE SET TO OPERATE THE WHOLE E <br /> THE ELEMENTS OF A BUILDING WHICH ENCLOSE CONDITIONED SPACES THROUGH WHICH THERMAL HOUSE SYSTEM FOR AT LEAST 8 HOURS A DAY. A LABEL SHALL BE AFFIXED TO THE W -- <br /> ENERGY MAY BE TRANSFERRED TO OR FROM THE EXTERIOR EXCEPT AS EXEMPTED BY THE W.S.E.C. CONTROL THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)". k O v <br /> GOW <br /> Date Jan.21 2020 ;!' <br /> Drawn By: JMP <br /> Sheet Number <br /> CITY OF EVERETT A7 <br /> REVIEWED FOR PERMIT <br />
The URL can be used to link to this page
Your browser does not support the video tag.