Drew Martin <br />From: Drew Martin <br />Sent: Monday, August 16, 2021 11:53 AM <br />To: paulg@weaverarch.com <br />Subject: City of Everett Permit Services: 3301 Seaway Blvd (132108-001) - First Building Intake <br />Review <br />Hello, Mr. Grundhoffer. <br />Your application has been received and a permit set up. However, the submitted documents are not sufficient <br />for us to perform a review at this time. Revised construction -level documents need to be submitted for <br />review. Preliminary comments are provided below to assist in revising the drawings, but these are not <br />intended to provide a comprehensive review. <br />The proposed project appears to involve installing two prefabricated rooms with lids in an existing <br />building. The submitted documents are not sufficient to show the proposed work. Sheet A.9A.1 only <br />shows isometric views of the framing for the two "DYNO" rooms; the Control Room is not shown. In <br />addition this sheet shows the rooms as "existing" with minor modifications. Architectural and <br />structural plans for the rooms should be provided showing compliance with the applicable <br />requirements of the IBC. Additional comments are provided below, but these are not intended as a <br />comprehensive list of all requirements that may apply to this project. <br />Architectural plans for the rooms should be provided. Information to be specified includes but is not <br />limited to: <br />a. Construction Type per IBC Chapter 6. The construction should be consistent with the permitted <br />type for the building. <br />b. Occupancy classification(s) for the rooms and the proposed uses. The occupancy(s) and uses <br />should be consistent with the permitted classification for the building, or as otherwise allowed <br />by IBC Chapter 5. <br />c. Egress doors. <br />3. Structural plans, including sections and details, and calculations should be submitted for review. The <br />plans and calculations should demonstrate compliance with IBC Chapter 16, ASCE 7-16, and the <br />applicable reference standards for the proposed material (e.g., steel, etc.). The lateral system should <br />comply with ASCE 7-16 Section 12.2.1. <br />Review of your project will be performed in the order received once the required documentation has been <br />submitted. Please let me know if you have questions. <br />— Drew Martin, P.E., S.E. <br />Associate Engineer —Commercial Plans Examiner I Permit Services <br />425.257.8810 13200 Cedar Street, 2nd Floor, Everett, WA 98201 <br />EVERETT Phone Hours: M/W/T: 8 am - 12 pm & 1 pm — 3 pm; Tu: 1:OOpm-3:OOpm <br />everettwa.gov/permits I Facebook I Twitter <br />Note: Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br />Records Act. <br />