My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3301 SEAWAY BLVD MAGNIX 2023-12-06
>
Address Records
>
SEAWAY BLVD
>
3301
>
MAGNIX
>
3301 SEAWAY BLVD MAGNIX 2023-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 8:13:34 AM
Creation date
9/7/2023 6:23:27 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3301
Tenant Name
MAGNIX
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
137
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br />From: Drew Martin <br />Sent: Wednesday, November 3, 2021 12:49 PM <br />To: paulg@weaverarch.com <br />Subject: City of Everett Permit Services: 3301 Seaway Blvd (132108-001) - First Building Review <br />Hello, Paul. <br />This email follows up on our conversation regarding this project. I have some questions for the structural engineer. This <br />email will effectively take the place of the review letter. Depending on the responses, we may be able to redline the <br />drawings without new drawings being produced; this may include taping in additional details. <br />Structural Comments <br />1. The structural has a 3-sided lateral system, omitting a frame on one side. The structure appears to potentially <br />have a Type 1a or 1b Horizontal Irregularity per ASCE 7-16 Table 12.3-1. The structural calculations do not <br />appear to include a torsional analysis. An analysis should be performed, including accidental torsion per Section <br />12.8.4.3 and amplification per Section 12.8.4.3 (ELFP used for analysis), and the design revised as <br />needed. Supplemental calculations should be submitted for review. Note that the deflection check preceding <br />the RISA model appears to be a basic deflection analysis and does not include torsional effects. <br />2. A story drift analysis should be performed per ASCE 7-16 Sections 12.8.4.3 and 12.12.1. The drifts should not <br />exceed the limits of Table 12.12.1. <br />3. The connection of the diaphragm to the vertical frames is required to comply with ASCE 7-16 Section 12.3.3.4 if <br />a torsional irregularity occurs. Additional calculations and details may be required. <br />4. The design loads are required to include a redundancy factor of 1.3 if a Type 1b Horizontal Irregularity occurs. <br />5. Verify if a connection is provided between the roof panels serving as the diaphragm and the center frame line. A <br />detail should be included. <br />6. The anchorage design calculations appear to include the overstrength factor per ACI 318-14 Sections <br />17.2.3.4.3(d) and 17.2.3.5.3(c). However, it appears the base input loads for tension and shear may be the net <br />loads from the applicable LRFD load factors. The overstrength factor is required to be applied to the seismic <br />component only, not the net uplift. The calculations should be revised as needed. <br />7. Continuing with the previous comment, the vertical load should include the vertical seismic effect per ASCE 7-16 <br />Sections 12.4.2 and 12.4.2.2. <br />8. Pending review of the previous two comments, it appears that the unmodified column connection types for two <br />and three anchors are sufficient with the 5/8" Hitli HAS rods. Verify these should be specified at the unmodified <br />base plates. See also Comment 12 below. <br />9. The design of the tension -only brace connections is based on a reduced design load, where the load determined <br />by analysis (i.e., 2.7 kips) has been reduced by the 160% load factor for the strap short-term increased capacity <br />(i.e., strap expected strength under short-term loading). This is not correct. See AISC 341-16 Section F2.6a. The <br />maximum load should be increased using the overstrength factor for a resulting ASD connection demand of <br />2.7*(52=2.0) = 5.4 kips. This exceeds the 3.44 kip screw capacity. <br />10. The columns at the intersection frames (i.e., the corners) should be designed for the orthogonal load effects per <br />ASCE 7-16 Section 12.5.4. <br />11. The columns should be designed for the strength requirements per AISC 341-16 Section D1.4a. <br />12. The column base plates and stiffeners should be designed per the requirements of AISC 341-16 Section D2.6. <br />Please let me know if you have questions. <br />
The URL can be used to link to this page
Your browser does not support the video tag.