r *2— <br /> ENGINEERING <br /> M LA <br /> 1424 Fourth Avenue, Suite 815 <br /> Seattle,WA 98101 <br /> T:206-264-2727 • F:206-264-4835 <br /> November 16, 2021 <br /> Drew Martin, P.E., S.E., <br /> City of Everett <br /> 3200 Cedar Street, 2nd Floor, <br /> Everett, WA 98201 <br /> Re: 3301 Seaway Blvd (B2108-001) - First Building Review <br /> Magnix Stand Alone Testing Room Seismic Retrofit <br /> Permit Review Responses <br /> Dear Mr. Martin: <br /> Please see below for MLA's comment responses for the seismic design for the Magnix testing <br /> frame as well as the amended calculations. Note the original permit comments are repeated and <br /> MLA's comments are provided in red. <br /> Structural Comments <br /> The structural has a 3-sided lateral system, omitting a frame on one side. The structure appears <br /> to potentially have a Type 1 a or lb Horizontal Irregularity per ASCE 7-16 Table 12.3-1. The <br /> structural calculations do not appear to include a torsional analysis. An analysis should be <br /> performed, including accidental torsion per Section 12.8.4.3 and amplification per Section <br /> 12.8.4.3 (ELFP used for analysis), and the design revised as needed. Supplemental calculations <br /> should be submitted for review. Note that the deflection check preceding the RISA model <br /> appears to be a basic deflection analysis and does not include torsional effects. Calculations have <br /> been modified and added Accidental Torsional with amplification. Note lateral loads were applied <br /> in the RISA model to in a way that reflects the distribution of the mass, and the RISA model <br /> automatically calculates stiffness, so the inherent torsion due to the rigidity vs mass in accounted <br /> for. See Appendix A for updates. Deflection has also been rechecked. See Appendix B. <br /> A story drift analysis should be performed per ASCE 7-16 Sections 12.8.4.3 and 12.12.1. The <br /> drifts should not exceed the limits of Table 12.12.1. Deflections updated to include accidental <br /> torsion. See Appendix B. <br /> The connection of the diaphragm to the vertical frames is required to comply with ASCE 7-16 <br /> Section 12.3.3.4 if a torsional irregularity occurs. Additional calculations and details may be <br /> required. See Appendix C for additional calculation for diaphragm connection and addition sketch <br /> SSK-5. <br /> The design loads are required to include a redundancy factor of 1.3 if a Type 1 b Horizontal <br /> Irregularity occurs. Model has been updated, redundancy factor is included in the EQ RISA load <br /> cases to be included in results and member forces. See Appendix A. <br /> Verify if a connection is provided between the roof panels serving as the diaphragm and the <br /> center frame line. A detail should be included. See Appendix C for additional calculation for <br /> diaphragm connection and addition sketch SSK-5. <br /> 1424 Fourth Ave,Suite 415 Tel:206.264.2727 <br /> Seattle,Washington 98101 Fax:206.264.4835 <br />