Laserfiche WebLink
NNW <br /> • <br /> Response to review comments <br /> 3301 Seaway Blvd (B2108-001) <br /> Novemb- • 4 <br /> Page 2 of 2 <br /> The anchorage design calculations appear to include the overstrength factor per ACI 318-14 <br /> Sections 17.2.3.4.3(d) and 17.2.3.5.3(c). However, it appears the base input loads for tension <br /> and shear may be the net loads from the applicable LRFD load factors. The overstrength factor is <br /> required to be applied to the seismic component only, not the net uplift. The calculations should <br /> be revised as needed. See Appendix D for clarification on the loads on columns and base plates. <br /> Continuing with the previous comment, the vertical load should include the vertical seismic effect <br /> per ASCE 7-16 Sections 12.4.2 and 12.4.2.2. See Appendix D for clarification on the loads on <br /> columns and base plates. <br /> Pending review of the previous two comments, it appears that the unmodified column connection <br /> types for two and three anchors are sufficient with the 5/8" Hilti HAS rods. Verify these should be <br /> specified at the unmodified base plates. See also Comment 12 below. See Appendix D for <br /> clarification on the loads on columns and base plates. <br /> The design of the tension-only brace connections is based on a reduced design load, where the <br /> load determined by analysis (i.e., 2.7 kips) has been reduced by the 160% load factor for the <br /> strap short-term increased capacity(i.e., strap expected strength under short-term loading). This <br /> is not correct. See AISC 341-16 Section F2.6a. The maximum load should be increased using <br /> the overstrength factor for a resulting ASD connection demand of 2.7*(W=2.0) = 5.4 kips. This <br /> exceeds the 3.44 kip screw capacity. See Appendix E for clarification on the strap sizing and strap <br /> connections to columns. <br /> The columns at the intersection frames (i.e., the corners) should be designed for the orthogonal <br /> load effects per ASCE 7-16 Section 12.5.4. See Appendix D for clarification on the loads on <br /> columns and base plates. <br /> The columns should be designed for the strength requirements per AISC 341-16 Section D1.4a. <br /> See Appendix D for clarification on the loads on columns and base plates. <br /> The column base plates and stiffeners should be designed per the requirements of AISC 341-16 <br /> Section D2.6. See Appendix D for clarification on the loads on columns and base plates. <br /> I am available should you have any questions. L S. L <br /> Sincerely, U A � ;, a\ <br /> MLA Engineering, LLC <ii� %I' ,/tia. <br /> 'rep, <br /> „: 20751 •:�,& <br /> o ssIONAL 0 <br /> Serena Baxter, P.E., S.E. Michael S. Leonard, P.E., S.E. <br /> Sr. Engineer Principal <br /> 1424 Fourth Ave,Suite 415 Tel:206.264.2727 <br /> Seattle,Washington 98101 Fax:206.264.4835 <br />