Laserfiche WebLink
11/18/22, 9:57 AM https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY19mdWxseV9jb25kaXRpb251ZCU3Q3BkX2NoZ19zcGFjZV9jb25kaXRpb25pbmcmdGZ... <br /> Project Title - ZAP Energy Tenant Improvement-2018 WSEC Date Nov 18,202? <br /> U x A Calculation CHANGE IN SPACE CONDITIONING-FULLY CONDITIONED COMPLIES <br /> Opaque Envelope Assemblies PROPOSED TARGET <br /> Roof/Ceiling Roof/Ceiling <br /> Roof'Ceiling Assembly ID Assembly U- Net Area(SF) U x A Assembly U- Net Area(SF) U x A <br /> Factor Factor <br /> Joist or single rafter Metal joist with cavity+rigid insulation 0.025 616.0 15.4 0.027 616.0 <br /> (1) <br /> Wall Wall <br /> Walls Assembly ID Assembly U- Net Area(SF) U x A Assembly U- Net Area(SF) U x A <br /> factor factor <br /> Steel-framed-Commercial Metal frame walls Type A 0.055 288.0 15.8 0.055 2(8)0 15.8 <br /> Fenestration and Opaque Door Assemblies PROPOSED TARGET <br /> — <br /> . Door Rough Opening Door Rough Opening <br /> Opaque Doors Assembly ID Assembly U- (SF) U x A Assembly U- (SF) U x A <br /> Factor Factor _ <br /> Swinging Double Doors to warehouse 0.37 42.0 15.5 0.37 ��'� 15.5 <br /> Proposed Area Proposed UxA Target Area Target UxA Target UxA with Adjustment <br /> Project Totals 946 47 946 48 53 <br /> NOTE:Change in space conditioning or occupancy allowance applied-1.10 multiplier has been applied to the Total Target UxA for exterior areas only.Refer to Target UxA with Adjustment. <br /> • <br /> 21c4 <br /> https://waenergycodes.com/print_project_summary_form.php?k=Y29tYm9fdGZ2X3BOPXNjY19mdWxseV9jb25kaXRpb251ZCU3Q3BkX2NoZ19zcG FjZV9jb25kaXRpb25pbmcmdGZ2PXNjY19mdMseV... <br />