My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2023-10-23
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2023-10-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 9:42:57 AM
Creation date
9/8/2023 12:05:46 PM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
review. An itemized response letter stating how each comment has been addressed should be included with the <br /> drawing. Additional revised documentation, including but not limited structural calculations and other supporting <br /> documentation, should be submitted as required. <br /> The following comments reference email correspondence from Capital Architects Group dated 11/04/2022 where <br /> indicated. <br /> Comments <br /> 1. The currently proposed project involves modifications in a space that is currently subject to work under the <br /> separate Permit No. B2104-064. The permit was issued for construction on 06/24/2021. The listed owner is Zap <br /> Energy, Inc. The Existing Floor Plan on Sheet A2.1 is not consistent with the plans shown in the previously issued <br /> permit. The current drawings should be revised for consistency. See IBC Section 107.2.1. <br /> 2. The email dated 11/01/2022 states that additional changes have been requested by the owner. The drawings <br /> should be revised as needed. See IBC Section 107.2.1. <br /> 3. The project involves converting existing unconditioned space to conditioned space. The response provided in <br /> the email dated 11/04/2022 stating the converted space is currently conditioned is not correct. The space is <br /> stated as unconditioned in the drawings for Permit No. B2104-064. The space does not appear to include the <br /> required insulation to qualify as conditioned,which is consistent with the documented history. The following <br /> comments should be addressed: <br /> a. The new envelope for the converted space should be insulated to comply with the exterior wall <br /> envelope requirements of WSEC Section C402. <br /> b. A schedule of energy credits should be included in the drawings complying with Section C406. The <br /> envelope requirements should be revised where required based on the selected credits. <br /> 4. The existing door on Grid H between the existing and new office spaces should comply with the requirements <br /> for recessed doors per ICC A117.1-09 Section 404.2.3.5. Based on a review of the drawings, it appears that the <br /> door will comply with these requirements. A note should be included for clarity stating that the recess on either <br /> side shall not exceed 8 inches measured from the door face to the wall face on either side. <br /> Please contact me if you have questions. Thank you. <br /> Drew Martin, P.E.,S.E. <br /> LI <br /> iii Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M/W/T:8 am-12 pm& 1 pm—3 pm;Tu: 1:oopm-3:oopm <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Enrolls and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> 2 <br />