Laserfiche WebLink
THERMOSTAT WIRE C7 3 <br /> z <br /> L <br /> O <br /> �# MECHANICAL NOTES= O Z <br /> O O <br /> I. PROVIDE 24"SERVICE CLEARANCE PER INSTRUCTIONS. CJ <br /> 2. AHU CONDENSATE DRAIN LINE NOT LESS THAN 1/8"PER FOOT SLOPE <br /> IN DIRECTION OF DISCHARGE.TYP.AND 3/4"0 MIN.OR <br /> MANUFACTURERS INSTRUCTIONS. <br /> 3. SINGLE LINE SHOWN FOR ILLUSTRATION.MAY NOT REPRESENT FINAL <br /> CONSTRUCTION ROUTE OR NUMBER OF CONNECTIONS.SEE ui Z <br /> SCHEDULES AND/OR INSTALL MANUAL FOR SPECIFIC LINE SIZES. X <br /> ry <br /> n Q m <br /> LCL EE a <br /> STAIR <br /> 171 <br /> 111 <br /> AHU-2 AHU 2 <br /> 15K BTU 7 15K BTU I <br /> - <br /> 1 1 <br /> AHU-2 <br /> hill ill I <br /> 15K BTU AHU-2 <br /> A4BTUK <br /> - 15K BTU <br /> I <br /> �77I 17 71 <br /> AHU-2 AHU-Z <br /> 15K BTU I 0 EN 15K BTU 1 <br /> OF ICE _ _ - <br /> 1 92 I T 50-3,10X10 -TW-2 <br /> 300 GFM 15K BTU <br /> D <br /> 1 FILTERT. <br /> M <br /> .SMINKLERNPE— <br /> LEE]10X10 ERV-1—12 0' <br /> 300 GFM SD-3,10X10 an <br /> QP�YTd1[tEA <br /> 250 GFM SSFF IB MI. <br /> DUCTWORK ONLY. EG-1,6X6 <br /> NOT CONNECTED I 50 CFM <br /> TO AIR DEVICE. EG-1,6x6 <br /> T <br /> FOR FIRST FLOOR 50 GFM RESTROOM WOMEN' '�'HU-4 <br /> FUTURE USE ONLY. 110 <br /> CFM, 209 - RESTBoo 9K BTU 25 CF 22X10 <br /> 25 CFM <br /> 6"X 32" BREAK - - - <br /> 6"X32FJ <br /> SIZE MAY CHANGE <br /> JANITOR T WABASIED ON FIELD <br /> 4 201 � GONDITION6. � <br /> AHU-3 /^' <br /> Ir-- <br /> v / <br /> ISK BTU T <br /> _ aTAx 7 U) <br /> �O� 1 B AHU-5 <br /> 18K BTU w <br /> 18K J ISK BTU <br /> LARGE CO F. J <br /> 36SF <br /> '�)E1 1 G2LLJ <br /> SOOS�N O� w C D <br /> DUCTWORK ONLY.NOT 207 � �//, Cn C14 <br /> CONNECTED TO AIR DEVICE.FOR �/ 4 EG-2,8X8 Q N CO <br /> FIRST FLOOR FUTURE USE ONLY. ® _ rL 100 CFM 1 CT <br /> SEE FLOOfizEI 50-4,10)124 <br /> 32 <br /> X32 <br /> Z5 GFM <br /> AHU-2 6 SD-2,8X8 II +' +� <br /> 15K BTU 115 CFM J 41 <br /> i I 6D-I,6X6 <br /> 1 60 CFM 204 200 GFM 100 CFM 5KU BTU N <br /> y UJ <br /> AHU-2 1 FLT 1 I 1 <br /> 15K BTU I AHU-1. <br /> 15K BTU <br /> T <br /> AHU-I , ERV-I i <br /> M I12K BTU I '� 1 <br /> 1 r le" r <br /> B ERVE ROO <br /> AHU-2 <br /> AHU-2 205 2/1SF 1 OH-2 20 15K BTU <br /> 15K BTU I IN. FILTER <br /> i I I <br /> AHU-2 AHU-2 <br /> 15K BTUISK BTU <br /> Z <br /> aw <br /> # o <br /> z <br /> o <br /> U) <br /> w � <br /> N <br /> N <br /> N N O <br /> a N <br /> U H <br /> z Q Q m <br /> Q <br /> Z <br /> 2 H ?< <br /> U F � < <br /> FIRST FLOOR MECHANICAL PLAN SECOND FLOOR MECHANICAL PLAN a <br /> w <br /> SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" M 1 <br /> N AN I . <br />