My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE ALLIED TELESIS INC 2025-03-27
>
Address Records
>
19TH AVE SE
>
10521
>
ALLIED TELESIS INC
>
10521 19TH AVE SE ALLIED TELESIS INC 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:43:30 PM
Creation date
9/13/2023 11:43:17 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
ALLIED TELESIS INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C403 VENTILATION SCHEDULE (D a <br /> 4"(MAINTAIN 3/4"MIN.) OCCUPANCY OUTSIDE AIR EXHAUST RATE KNOWN MIN.OSA CFM OSA CFM MIN.EXHAUST CFM EXHAUST ui Z �: <br /> FLOOR ROOM LABEL AREA(SF) IMC 2015 CLASSIFICATION CFM/PERSON NOTES - W <br /> fl/1000 RATE REQUIRED OCCUPANCY REQUIRED PROVIDED REQUIRED PROVIDEDO <br /> 2 Open Office 2765 Office spaces 5 5 0.06 0 235 275 0 290 O Z <br /> 2 Wellness Room 211 Office spaces 5 5 0.06 0 18 25 0 0 O O <br /> FIRE SPRINKLER 2 Lab Work Area 1093 Office spaces 5 5 0.06 0 93 100 0 200 <br /> V <br /> CLOUD 2 Lab Work Area 674 Office spaces 5 5 0.06 0 57 60 0 0 U ob <br /> 2 Conference Room 370 Conference rooms 50 5 0.06 0 115 115 0 100 ' I 0 Lo <br /> WINDOWAHU-2 4 2 Reception 673 Reception areas 30 5 0.06 0 141 150 0 0 L1J Z <br /> 2 Break Room 696 Kitchenettes 25 5 0.06 0.3 129 150 209 210 X <br /> 2 Men's Restroom 100 Toilet rooms-public 0 0 0 50/70 e 0 0 50 50 1 ^ Q 0 <br /> 2 Women's Restroom 100 Toi l et rooms-public 0 0 0 50/70e 0 0 50 50 1 / ' w O <br /> ISL 2 a <br /> 2 Storage Room 201 Storage rooms 0 0 0.12 0 24 25 0 0 <br /> 2 Server Room 281 N/A 0 0 0 0 0 0 0 0 <br /> 4-19TOF// g• 9-4 812 900 309 900 <br /> OF WI DOW NOTES: <br /> 1.PROVIDE LESSER AIR WHEN RUN CONTINUOUSLY. <br /> ERV SCHEDULE <br /> TEMPERATURE RECOVERY EFFICIENCY% ENTHALPY RECOVERY EFFICIENCY% ELECTRICAL <br /> DESIGN COOLING W HEATING @ COOLING @ HEATING @ EXTERNAL STATIC SOUND <br /> TAG DESIGN BASIS MODEL AIRFLOW 7S%/100%AIRFLOW 75%/100%AIRFLOW 75%/100%AIRFLOW 7S%/100%AIRFLOW PRESSURE(H/L) PRESSURE POWER SUPPLY MCA MOP DIMENSIONS(Wx H x D)(in.) WEIGHT(lbs.) NOTES <br /> ERVA DAWN VAM300GVJU 300 70%/65% 69%/65% 48%/40% 63%/57% .64/.16 54.0 dba 208/230-1-60 1.6 15 12-1/16x34-5/8x31-1/2 71 1 <br /> ERV-2 DAWN VAM600GVJU 600 74%/72% 73%/70% 74%/72% 73%/70% .76/.32 57.7 dba 208/230-1-60 4.2 15 15-1/4x43-11/16x47-13/16 148 1 <br /> a D D a D D D <br /> NOTES: <br /> 1.PROVIDE WIRELESS CONTROLLER. <br /> 3-734" 434" MULTI-PORT DISTRIBUTION UNITS <br /> ELECTRICAL ODUTO MAINMDC MAIN MDC TO SUB MDC <br /> CONNECTED MAX CAPACITY MAX CONNECTED HIGH PRESSURE LOW PRESSURE DESIG91,2 <br /> TAG QTY BASIS OF DESIGN MODEL PORTS PORTS CAPACTIY UTILIZED PER PORT CAPACITY SUPPLY MCA MOCP (MIXED PHASE) (GAS) HIGH PRESSURE LOW PRESSURE LIQUID (HIGH NOTES <br /> TO BOTTOM OF JOISTS BC-1 1 CARRIER 40VMD016M-3 16 12 186,000 BTU/H 54 Kbtu/h 360,000 BTU/H 208/230-1-60 1.54 15 5/8-1-1/8 3/4-1-3/8 5/8-7/8 3/4-1-1/8 3/8-5/8 51,2 <br /> I'-34" BC-2 1 CARRIER 40VMD01OM--3 10 9 127,000 BTU/H 54 Kbtu/h 360,000 BTU/H 208/230-1-60 1.05 15 5/8-1-1/8 3/4-1-3/8 5/8-7/8 3/4-1-1/8 3/8-5/8 5 <br /> NOTES: <br /> 1.SEE INSTALL INSTRUCTIONS/SUBMITTAL FOR OUTDOOR UNIT FOR SPECIFIC UNE SIZE. <br /> VA M 6000 VJ U 2.SEE I NSTALL INSTRUCTION/SUBMITTAL FOR INDI VIDIAL UNIT REFRIGERATION U NE SIZE. <br /> INDOOR AIR CONTROL UNITS <br /> ELECTRICAL <br /> 10 CAPACITY(BTU/HR) DESIGN REFRIGERATION REFRIG.SIZE(in.) ELECTRICAL SOUND LEVEL DIMENSIONS WEIGHT <br /> TAG BASIS OF DESIGN MODEL NO. COOLING/HEATING AIRFLOW TYPE (LIQUID/SUCTION) DRAIN SIZE POWER SUPPLY (MCA/MOPD) dB(A) (W x H x D)(in.) (lbs.) NOTES <br /> 8 4 AHU-1 CARRI ER 40VMC012-3 12,000/13,000 359 R-410A 1/4/1/2 1" 208-230/1/60 .53/15 45.5 24-3/4 x 10-1/4 x 22-7/16 43 <br /> AHU-2 CARRI ER 40VMC015A--3 15,210/17,000 359 R-410A 1/4/1/2 V. 208-230/1/60 .53/15 45.5 24-3/4 x 10-1/4 x 22-7/16 43 U) <br /> AHU-3 CARRI ER 40VMFO18A--3 18,250/21,000 700 R-410A 3/8-5/8 1-1/4" 208-230/1/60 2/15 43.1 33-1/8 x 11-3/4 x 33-1/8 69 <br /> AHU-4 CARRI ER 40VMWO09-3 9,630/10,900 320 R-410A 1/4-1/2 3/4" 208-230/1/60 .45/15 34.5 36 x 11-3/8 x 9 28 <br /> AHU-5 CARRI ER 40VMWO18-3 18,250/21,000 470 R-410A 3/8-5/8 3/4" 208-230/1/60 .45/15 40.2 42-1/4 x 12-3/8 x 9 32 W <br /> NOTES: J <br /> W <br /> L1J OO <br /> 2 0 0 0 0 0 o OUTDOOR ROOFTOP UNIT SCHEDULE (n N <br /> LNOMINAL FACTORY GASCONNECTION POWER ELECTRICAL(amps) SOUND LEVEL DIMENSIONS WEIGHT Oj <br /> TAG BASIS OF DESIGN MODEL p TONS EER/IEER REFRIG.TYPE CHARGE SIZE(HIGH/LOW) FAN HP DRIVE TYPE SUPPLY (MCA/FUSE) (dB) (W x D x H)(in.) (Ibs.) NOTES > Q <br /> ODU-1 CARRIER 38VMA264RD55-1 22 10.4/110 f R-410A 77.2 LB 1-1/8/1-3/8 .0265x4 kW Brushless DC 208-2303/60 104/110 65.8 105-7/8 x 64-3/8 x 31-1/8 1627 > <br /> J <br /> Ch � <br /> NOTES: J N <br /> O LL,IL <br /> DUCT HEATER SCHEDULE <br /> ELECTRICAL <br /> TAG MAKE MODEL kW STAGES POWER SUPPLY AMPS DIMENSION NOTES <br /> DH-1 WARREN CBK 2.5 1 208-230/60/1 10.42 FLA 10" <br /> DH-2 WARREN CBK 5 1 208-230/60/1 20.83 FLA 12" <br /> NOTES: <br /> N <br /> DIFFUSERS AND GRILLE SCHEDULE <br /> TAG QTY DESIGN BASIS MODEL MOUNT FACE NECK SIZE NOTES 0 <br /> SD-1 2 TITUS 30ORS SURFACE/GRID 6x6 N/A a o <br /> SD-2 1 TITUS 30ORS SURFACE/GRID 8x8 N/A Vl <br /> SD-3 2 TITUS 30ORS SURFACE/GRID 10x10 N/A O u <br /> SD-4 1 TITUS 30ORS T-BAR 22x10 6" <br /> EG-1 2 TITUS 350RL SURFACE 6x6 N/A � � N <br /> EG-2 3 TITUS 350RL SURFACE 8x8 N/A <br /> N <br /> EG-3 1 TITUS 350RL SURFACE 10x10 N/A N M <br /> 0 <br /> 12 Z N <br /> NOTES: N <br /> a L N <br /> U H <br /> Z Q Q m <br /> Q <br /> Z <br /> 2 <br /> H <br /> w <br /> ELEVATIONS EQUIPMENT SCHEDULES M4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.