Laserfiche WebLink
-COFFMAN <br /> ENGINEERS <br /> 1101 2nd Avenue,Suite 400 <br /> ELECTRICAL SYMBOLS ELECTRICAL ABBREVIATIONS <br /> Seattle,WA 98101 <br /> LIGHTING RECEPTACLES AD AUTO DOOR FAM FIRE ALARM ANNUNCIATOR PANEL PS PROJECTION SCREEN ph 206.623.0717 <br /> AF AMPERE FRAME FACP FIRE ALARM CONTROL PANEL PTR PRINTER <br /> F� <br /> FIXTURE TYPE DUPLEX RECEPTACLE-NEMA 5-15R(NEMA 5-20R FOR DEDICATED CIRCUIT) AFF ABOVE FINISHED FLOOR FDMPR FIRE DAMPER PVC POLYVINYL CHLORIDE(PLASTIC) <br /> SWITCH ZONE: l�nC DUPLEX RECEPTACLE-ABOVE COUNTER. COORDINATE W/ARCH.ELEVATIONS AHU AIR HANDLING UNIT FH FUME HOOD PWR POWER www.coffman.com <br /> UPPERCASE LETTER X INDICATES TIME AIC AMPERE INTERRUPTING CURRENT FMT FLEXIBLE METAWC TUBING QTY QUANTITY <br /> vvvv X(a) CLOCK CONTROL DUPLEX RECEPTACLE-DEDICATED(NEMA 5-20R) AMP AMPERE FU or F FUSE RA FAN RETURN AIR FAN <br /> LOWERCASE LETTER x INDICATES LOCAL D AS AMPERE SWITCH FVNR FULL VOLTAGE NON-REVERSING RECPT RECEPTACLE <br /> EM OCCUPANCY/VACANCY SENSOR CONTROL qWP DUPLEX RECEPTACLE-WEATHERPROOF ASV AIR SOLENOID VALVE G GROUND REF REFRIGERATOR <br /> L (a)INDICATES DAYLIGHT ZONE AT AMPERE TRIP GALV GALVANIZED READ REQUIRED <br /> CONTROLLED BY PHOTOCELL(WHERE qTR DUPLEX RECEPTACLE-TAMPER RESISTANT ATS AUTOMATIC TRANSFER SWITCH GC GOGGLE CABINET RH RANGE HOOD <br /> SHOWN) AWG AMERICAN WIRE GAUGE GO GARBAGE DISPOSAL RMC RIGID METAL CONDUIT <br /> ,,��}},, DUPLEX RECEPTACLE-GROUND FAULT CIRCUIT INTERRUPTER <br /> YYGFCI BAS BUILDING AUTOMATION SYSTEM GEC GROUNDING ELECTRODE CONDUCTOR RNG RANGE <br /> FIXTURE IS ON EMERGENCY POWER T <br /> Yf USB DUPLEX RECEPTACLE-UNIVERSAL SERIAL BUS BBO BACKBOARD OPERATOR GEN GENERATOR RSD ROWNG STEEL DOOR <br /> BL BLEACHERS GFCI GROUND FAULT CIRCUIT INTERRUPTER SDMPR SMOKE DAMPER <br /> ® EXIT SIGN,CEILING MOUNT DOUBLE DUPLEX RECEPTACLE BLDG BUILDING GSV GAS SOLENOID VALVE SF SUPPLY FAN <br /> REFER TO ARCHITECTURAL LIFE SAFETY ,H, C CONDUIT HH HAND HOLE SOLV SOLENOID VALVE <br /> PLAN FOR DIRECTION OF TRAVEL `I-Y DUPLEX RECEPTACLE-CEILING MOUNTED CAB CABINEr HID HIGH INTENSITY DISCHARGE SPD SURGE PROTECTIVE DEVICE <br /> EXIT SIGN,WALL MOUNT DUPLEX RECEPTACLE WITH TOP OUTLEr CONTROLLED CB CIRCUIT BREAKER HP HORSEPOWER SPEC SPECIFICATION <br /> REFER TO ARCHITECTURAL LIFE SAFETY AC CCN CLOSED CIRCUIT TELEVISION HPF HIGH POWER FACTOR SPST SINGLE POLE,SINGLE THROW <br /> PLAN FOR DIRECTION OF TRAVEL ABOVE COUNTER DUPLEX RECEPTACLE WITH TOP OUTLET CONTROLLED CKT CIRCUIT HPS HIGH PRESSURE SODIUM ST SHUNT TRIP ALLIED <br /> OS CEILING MOUNTED DUAL TECHNOLOGY DOUBLE DUPLEX RECEPTACLE WITH ONE DUPLEX CONTROLLED CM CEILING HT HEAT TRACE STD STANDARD <br /> CMSPECIAL RECEPTACLE-TYPE AS INDICATED COFFEE MAKER IH INSTANCY STN STEEL TELESIS <br /> OCCUPANCY OR VACANCY SENSOR � CMU CONCRETE MASONRY UNIT IM ICE MACHINE SW SWITCH ODAYLIGHT SENSOR(x,y)INDICATES ZONES CO CONDUIT ONLY TWO INTERCOM WALL DISPLAY SWBD SWITCHBOARD <br /> L(a b) CONTROLLED © CORD REEL COMM COMMUNICATION J-BOX JUNCTION BOX SWGR SWITCHGEAR <br /> R CONTROLLED RECEPTACLE RELAY COP COPIER kcmil THOUSAND CIRCULAR MILS TEL TELEPHONE <br /> ❑ CT COOK TOP kV KILOVOLT TEMP TEMPORARY Silver Plaza <br /> DMULTI-SWCHSON ON/OFF DIM UP/DOWN Cu COPPER CT CURRENT TRANSFORMER kW KILOWATT kVA KILOVOLT PERE TR TTP RAPERRIMERRESIANT Floor 2 <br /> xy=SWITCHED LEG CONTROLLED EQUIPMENT DCVA DOUBLE CHECK VALVE ASSEMBLY kWh KILOWATT HOUR TIE TELEPHONE TERMINAL BOARD <br /> PROVIDE SEPARATE ON/OFF DET DETAIL MAX MAXIMUM TYR TYPICAL <br /> FUNCTIONALITY FOR EACH SWITCH LEG10521 19th Ave SE <br /> NOTED. 1ii�m PANELBOARD 277/480V DIA DIAMETER MCC MOTOR CONTROL CENTER UC UNDER COUNTER <br /> DISC DISCONNECT MFR MANUFACTURER UGND UNDERGROUND Everett, WA 98202 <br /> TWO-BUTTON ON/OFF SWITCH G PANELBOARD 120/208V OR 120/240V DSPL DISPOSAL MECH MECHANICAL UH UNIT HEATER <br /> X=SWITCHED LEG CONTROLLED DLC DOOR LOCK CONTROLLER MH MANHOLE;METAL HACABINET-TYPE AS INDICATED ON PLAN LIDE UL UNDERWRITERS LABORATORIES <br /> PROVIDE SEPARATE ON/OFF ON DOWN MIN MINIMUM LION UNLESS OTHERWISE NOTED <br /> FUNCTIONALITY FOR EACH SWITCH LEG ® SWITCHBOARD DO DOOR OPERATOR ML MAGNETIC LOCK UPS UNINTERRUPTIBLE POWER SUPPLY Construction Set <br /> NOTED. DPST DOUBLE POLE,SINGLE THROW MLO MAIN LUGS ONLY USE UNIVERSAL SERIAL BUS <br /> $SC MULTI-BUTTON SCENE CONTROL SWITCH WITH ❑ TRANSFORMER-SIZE AND VOLTAGE AS INDICATED ON PLAN DRY DRYER MTD MOUNTED V VOLT Revisions <br /> DIM UP/DOWN DW DISHWASHER MTG MOUNTING VA VOLT AMPERE <br /> �D $M HORSEPOWER RATED TOGGLE SWITCH WITH OVERLOAD PROTECTION DWG DRAWING MW MICROWAVE VFD VARIABLE FREQUENCY DRIVE <br /> �VVOO OCCUPANCY OR VACANCY SENSOR SWITCH 5t COMBINATION STARTER EA EACH NEC NATIONAL ELECTRICAL CODE VM VENDING MACHINE <br /> WITH ON/OFF AND DIM UP/DOWN EF EXHAUST FAN NEUT NEUTRAL W WATT <br /> FUNCTIONALLY HP RATED,3-POLE,NEMA 1 MINIMUM UNLESS NOTED EH ELECTRIC HEATER NC NORMALLY CLOSED W/ WITH <br /> OTHERWISE-OVERCURRENT PROTECTION AS REQUIRED <br /> $DS OCCUPANCY OR VACANCY SENSOR SWITCHEHD ELECTRIC HAND DRYER NIC NOT IN CONTRACT WAC WASHINGTON ADMINISTRATIVE CODE <br /> El, NON-FUSED DISCONNECT SWITCH-SIZE PER CONNECTED LOAD ELEC ELECTRIC NO NUMBER;NORMALLY OPEN WAS WASHER <br /> ELEV ELEVATOR NTS NOT TO SCALE W/D STACKED WASHER/DRYER <br /> ON/OFF TOGGLE SWITCH Eh FUSED DISCONNECT SWITCH-SIZE PER CONNECTED LOAD. EMT ELECTRICAL METALLIC TUBING OD OVERHEAD(COILING)DOOR WF WASH FOUNTAIN <br /> $3 THREE WAY TOGGLE SWITCH ON/OFF SWITCH PROVIDE FUSES PER EQUIPMENT NAMEPLATE. EPO EMERGENCY POWER OFF OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED WM WASHING MACHINE <br /> ®XX EQUIPMENT CONNECTION EQUIP EQUIPMENT OF/OI OWNER FURNISHED/OWNER INSTALLED W/0 WITHOUT <br /> OCCUPANCY SENSOR,IR,CEILING MOUNT REFER TO EQUIPMENT CONNECTION SCHEDULE ON GENERAL EWC ELECTRIC WATER COOLER PF POWER FACTOR WON WON DOOR <br /> H@ OCCUPANCY SENSOR,DUAL TECHNOLOGY, NOTES SHEET WHEN"XX*IS SHOWN. EWH ELECTRIC WATER HEATER PH or 0 PHASE WP WEATHERPROOF;WATERPROOFING <br /> WALL MOUNTEWS ELECTRIC WINDOW SHADE PIV POST INDICATOR VALVE XFMR TRANSFORMER <br /> EF_1 MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL EXIST EXISTING PNL PANEL Z IMPEDANCE <br /> © CONTACTOR EQUIPMENT SCHEDULE. FA FIRE ALARM PROJ PROJECTOR <br /> ® RELAY FLUSH FLOOR BOX <br /> ® LIGHTING ROOM CONTROLLER-SUBSCRIPT O POKE THRU FITTING <br /> obc INDICATES NUMBER OF CONTROL ZONES. Q FF POKE THRU FITTING WITH FURNITURE FEED <br /> PROVIDE ONE RELAY FOR EACH CONTROL <br /> ZONE. FF WALL FURNITURE FEED Registration <br /> Raba LIGHTING ROOM CONTROLLER(DIMMING)- E PP POWER POLE DRAWING INDEX $ <br /> SUBSCRIPT INDICATES NUMBER OF DIMMING <br /> ZONES. PROVIDE ONE RELAY FOR EACH SHEET NUMBER DESCRIPTION WASg� <br /> DIMMING ZONE. 'tc <br /> EMERGENCY BATTERY BACKUP LIGHT RACEWAYS E-0.1 COVER SHEET AND GENERAL INFORMATION _ <br /> E-0.2 GENERAL NOTES t- <br /> RACEWAY CONCEALED IN WALL OR CEILING,EXPOSED IN UNFINISHED AREAS E-0.4 NREC <br /> ELECTRICAL RISER ____ �o k 45932 <br /> RACEWAY CONCEALED BELOW FLOOR ,n. <br /> E-2.1 LIGHTING PLAN AGISTER <br /> `s`S/ONAL <br /> GROUND FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS 3012023 <br /> E-3.1 POWER PLAN <br /> A-1,3,5 BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. <br /> 30A/3P CIRCUIT BREAKER PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. E-4.1 MECHANICAL POWER PLAN Key Plan <br /> o— NUMBER INDICATES TRIP SETING AND NUMBER OF <br /> 400AF/300AT POLES RACEWAY TURNING UP E-5.1 ONE-LINE DIAGRAM&FEEDER SCHEDULES <br /> _5-b_ ADJUSTABLE TRIP CIRCUIT BREAKER <br /> RACEWAY TURNING DOWN E-6.1 PANEL SCHEDULES <br /> 40000AS/300AF NUMBERS INDICATE FRAME SIZE/TRIP SETTING CIRCUIT CONTINUATION <br /> FUSED DISCONNECT SWITCH —LV— LOW VOLTAGE WIRING <br /> NUMBERS INDICATE SWITCH SIZE/FUSE SIZE <br /> PNL m JUNCTION BOX <br /> PANELBOARD PB PULL BOX <br /> CURRENT TRANSFORMER(CT) <br /> V CABLE TO BUS CONNECTION <br /> COVER SHEET <br /> Y o AUTOMATIC TRANSFER SWITCH(ATS) AND GENERAL <br /> <am> FEEDER TYPE-REFER TO FEEDER SCHEDULE ON INFORMATION <br /> ONE-UNE <br /> W3 UTILITY METER <br /> ® BRANCH CIRCUIT METER <br /> Scala: NONE <br /> CEI Project No: 230312 <br /> @-3 FEEDER METER <br /> Date: 3.7.2023 <br /> D SURGE PROTECTIVE DEVICE(SPD) Designed: J. MAXWELL <br /> XX,XXX AVAILABLE SYMMETRICAL FAULT CURRENT IN AMPS Drawn: R. FROGGEChecked: B. MAXWELL <br /> Sheet Number <br /> E-0 . 1 <br />