My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10521 19TH AVE SE ALLIED TELESIS INC 2025-03-27
>
Address Records
>
19TH AVE SE
>
10521
>
ALLIED TELESIS INC
>
10521 19TH AVE SE ALLIED TELESIS INC 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 2:43:30 PM
Creation date
9/13/2023 11:43:17 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
10521
Tenant Name
ALLIED TELESIS INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-COFFMAN <br /> ENGINEERS <br /> 1101 2nd Avenue,Suite 400 <br /> ELECTRICAL SYMBOLS ELECTRICAL ABBREVIATIONS <br /> Seattle,WA 98101 <br /> LIGHTING RECEPTACLES AD AUTO DOOR FAM FIRE ALARM ANNUNCIATOR PANEL PS PROJECTION SCREEN ph 206.623.0717 <br /> AF AMPERE FRAME FACP FIRE ALARM CONTROL PANEL PTR PRINTER <br /> F� <br /> FIXTURE TYPE DUPLEX RECEPTACLE-NEMA 5-15R(NEMA 5-20R FOR DEDICATED CIRCUIT) AFF ABOVE FINISHED FLOOR FDMPR FIRE DAMPER PVC POLYVINYL CHLORIDE(PLASTIC) <br /> SWITCH ZONE: l�nC DUPLEX RECEPTACLE-ABOVE COUNTER. COORDINATE W/ARCH.ELEVATIONS AHU AIR HANDLING UNIT FH FUME HOOD PWR POWER www.coffman.com <br /> UPPERCASE LETTER X INDICATES TIME AIC AMPERE INTERRUPTING CURRENT FMT FLEXIBLE METAWC TUBING QTY QUANTITY <br /> vvvv X(a) CLOCK CONTROL DUPLEX RECEPTACLE-DEDICATED(NEMA 5-20R) AMP AMPERE FU or F FUSE RA FAN RETURN AIR FAN <br /> LOWERCASE LETTER x INDICATES LOCAL D AS AMPERE SWITCH FVNR FULL VOLTAGE NON-REVERSING RECPT RECEPTACLE <br /> EM OCCUPANCY/VACANCY SENSOR CONTROL qWP DUPLEX RECEPTACLE-WEATHERPROOF ASV AIR SOLENOID VALVE G GROUND REF REFRIGERATOR <br /> L (a)INDICATES DAYLIGHT ZONE AT AMPERE TRIP GALV GALVANIZED READ REQUIRED <br /> CONTROLLED BY PHOTOCELL(WHERE qTR DUPLEX RECEPTACLE-TAMPER RESISTANT ATS AUTOMATIC TRANSFER SWITCH GC GOGGLE CABINET RH RANGE HOOD <br /> SHOWN) AWG AMERICAN WIRE GAUGE GO GARBAGE DISPOSAL RMC RIGID METAL CONDUIT <br /> ,,��}},, DUPLEX RECEPTACLE-GROUND FAULT CIRCUIT INTERRUPTER <br /> YYGFCI BAS BUILDING AUTOMATION SYSTEM GEC GROUNDING ELECTRODE CONDUCTOR RNG RANGE <br /> FIXTURE IS ON EMERGENCY POWER T <br /> Yf USB DUPLEX RECEPTACLE-UNIVERSAL SERIAL BUS BBO BACKBOARD OPERATOR GEN GENERATOR RSD ROWNG STEEL DOOR <br /> BL BLEACHERS GFCI GROUND FAULT CIRCUIT INTERRUPTER SDMPR SMOKE DAMPER <br /> ® EXIT SIGN,CEILING MOUNT DOUBLE DUPLEX RECEPTACLE BLDG BUILDING GSV GAS SOLENOID VALVE SF SUPPLY FAN <br /> REFER TO ARCHITECTURAL LIFE SAFETY ,H, C CONDUIT HH HAND HOLE SOLV SOLENOID VALVE <br /> PLAN FOR DIRECTION OF TRAVEL `I-Y DUPLEX RECEPTACLE-CEILING MOUNTED CAB CABINEr HID HIGH INTENSITY DISCHARGE SPD SURGE PROTECTIVE DEVICE <br /> EXIT SIGN,WALL MOUNT DUPLEX RECEPTACLE WITH TOP OUTLEr CONTROLLED CB CIRCUIT BREAKER HP HORSEPOWER SPEC SPECIFICATION <br /> REFER TO ARCHITECTURAL LIFE SAFETY AC CCN CLOSED CIRCUIT TELEVISION HPF HIGH POWER FACTOR SPST SINGLE POLE,SINGLE THROW <br /> PLAN FOR DIRECTION OF TRAVEL ABOVE COUNTER DUPLEX RECEPTACLE WITH TOP OUTLET CONTROLLED CKT CIRCUIT HPS HIGH PRESSURE SODIUM ST SHUNT TRIP ALLIED <br /> OS CEILING MOUNTED DUAL TECHNOLOGY DOUBLE DUPLEX RECEPTACLE WITH ONE DUPLEX CONTROLLED CM CEILING HT HEAT TRACE STD STANDARD <br /> CMSPECIAL RECEPTACLE-TYPE AS INDICATED COFFEE MAKER IH INSTANCY STN STEEL TELESIS <br /> OCCUPANCY OR VACANCY SENSOR � CMU CONCRETE MASONRY UNIT IM ICE MACHINE SW SWITCH ODAYLIGHT SENSOR(x,y)INDICATES ZONES CO CONDUIT ONLY TWO INTERCOM WALL DISPLAY SWBD SWITCHBOARD <br /> L(a b) CONTROLLED © CORD REEL COMM COMMUNICATION J-BOX JUNCTION BOX SWGR SWITCHGEAR <br /> R CONTROLLED RECEPTACLE RELAY COP COPIER kcmil THOUSAND CIRCULAR MILS TEL TELEPHONE <br /> ❑ CT COOK TOP kV KILOVOLT TEMP TEMPORARY Silver Plaza <br /> DMULTI-SWCHSON ON/OFF DIM UP/DOWN Cu COPPER CT CURRENT TRANSFORMER kW KILOWATT kVA KILOVOLT PERE TR TTP RAPERRIMERRESIANT Floor 2 <br /> xy=SWITCHED LEG CONTROLLED EQUIPMENT DCVA DOUBLE CHECK VALVE ASSEMBLY kWh KILOWATT HOUR TIE TELEPHONE TERMINAL BOARD <br /> PROVIDE SEPARATE ON/OFF DET DETAIL MAX MAXIMUM TYR TYPICAL <br /> FUNCTIONALITY FOR EACH SWITCH LEG10521 19th Ave SE <br /> NOTED. 1ii�m PANELBOARD 277/480V DIA DIAMETER MCC MOTOR CONTROL CENTER UC UNDER COUNTER <br /> DISC DISCONNECT MFR MANUFACTURER UGND UNDERGROUND Everett, WA 98202 <br /> TWO-BUTTON ON/OFF SWITCH G PANELBOARD 120/208V OR 120/240V DSPL DISPOSAL MECH MECHANICAL UH UNIT HEATER <br /> X=SWITCHED LEG CONTROLLED DLC DOOR LOCK CONTROLLER MH MANHOLE;METAL HACABINET-TYPE AS INDICATED ON PLAN LIDE UL UNDERWRITERS LABORATORIES <br /> PROVIDE SEPARATE ON/OFF ON DOWN MIN MINIMUM LION UNLESS OTHERWISE NOTED <br /> FUNCTIONALITY FOR EACH SWITCH LEG ® SWITCHBOARD DO DOOR OPERATOR ML MAGNETIC LOCK UPS UNINTERRUPTIBLE POWER SUPPLY Construction Set <br /> NOTED. DPST DOUBLE POLE,SINGLE THROW MLO MAIN LUGS ONLY USE UNIVERSAL SERIAL BUS <br /> $SC MULTI-BUTTON SCENE CONTROL SWITCH WITH ❑ TRANSFORMER-SIZE AND VOLTAGE AS INDICATED ON PLAN DRY DRYER MTD MOUNTED V VOLT Revisions <br /> DIM UP/DOWN DW DISHWASHER MTG MOUNTING VA VOLT AMPERE <br /> �D $M HORSEPOWER RATED TOGGLE SWITCH WITH OVERLOAD PROTECTION DWG DRAWING MW MICROWAVE VFD VARIABLE FREQUENCY DRIVE <br /> �VVOO OCCUPANCY OR VACANCY SENSOR SWITCH 5t COMBINATION STARTER EA EACH NEC NATIONAL ELECTRICAL CODE VM VENDING MACHINE <br /> WITH ON/OFF AND DIM UP/DOWN EF EXHAUST FAN NEUT NEUTRAL W WATT <br /> FUNCTIONALLY HP RATED,3-POLE,NEMA 1 MINIMUM UNLESS NOTED EH ELECTRIC HEATER NC NORMALLY CLOSED W/ WITH <br /> OTHERWISE-OVERCURRENT PROTECTION AS REQUIRED <br /> $DS OCCUPANCY OR VACANCY SENSOR SWITCHEHD ELECTRIC HAND DRYER NIC NOT IN CONTRACT WAC WASHINGTON ADMINISTRATIVE CODE <br /> El, NON-FUSED DISCONNECT SWITCH-SIZE PER CONNECTED LOAD ELEC ELECTRIC NO NUMBER;NORMALLY OPEN WAS WASHER <br /> ELEV ELEVATOR NTS NOT TO SCALE W/D STACKED WASHER/DRYER <br /> ON/OFF TOGGLE SWITCH Eh FUSED DISCONNECT SWITCH-SIZE PER CONNECTED LOAD. EMT ELECTRICAL METALLIC TUBING OD OVERHEAD(COILING)DOOR WF WASH FOUNTAIN <br /> $3 THREE WAY TOGGLE SWITCH ON/OFF SWITCH PROVIDE FUSES PER EQUIPMENT NAMEPLATE. EPO EMERGENCY POWER OFF OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED WM WASHING MACHINE <br /> ®XX EQUIPMENT CONNECTION EQUIP EQUIPMENT OF/OI OWNER FURNISHED/OWNER INSTALLED W/0 WITHOUT <br /> OCCUPANCY SENSOR,IR,CEILING MOUNT REFER TO EQUIPMENT CONNECTION SCHEDULE ON GENERAL EWC ELECTRIC WATER COOLER PF POWER FACTOR WON WON DOOR <br /> H@ OCCUPANCY SENSOR,DUAL TECHNOLOGY, NOTES SHEET WHEN"XX*IS SHOWN. EWH ELECTRIC WATER HEATER PH or 0 PHASE WP WEATHERPROOF;WATERPROOFING <br /> WALL MOUNTEWS ELECTRIC WINDOW SHADE PIV POST INDICATOR VALVE XFMR TRANSFORMER <br /> EF_1 MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL EXIST EXISTING PNL PANEL Z IMPEDANCE <br /> © CONTACTOR EQUIPMENT SCHEDULE. FA FIRE ALARM PROJ PROJECTOR <br /> ® RELAY FLUSH FLOOR BOX <br /> ® LIGHTING ROOM CONTROLLER-SUBSCRIPT O POKE THRU FITTING <br /> obc INDICATES NUMBER OF CONTROL ZONES. Q FF POKE THRU FITTING WITH FURNITURE FEED <br /> PROVIDE ONE RELAY FOR EACH CONTROL <br /> ZONE. FF WALL FURNITURE FEED Registration <br /> Raba LIGHTING ROOM CONTROLLER(DIMMING)- E PP POWER POLE DRAWING INDEX $ <br /> SUBSCRIPT INDICATES NUMBER OF DIMMING <br /> ZONES. PROVIDE ONE RELAY FOR EACH SHEET NUMBER DESCRIPTION WASg� <br /> DIMMING ZONE. 'tc <br /> EMERGENCY BATTERY BACKUP LIGHT RACEWAYS E-0.1 COVER SHEET AND GENERAL INFORMATION _ <br /> E-0.2 GENERAL NOTES t- <br /> RACEWAY CONCEALED IN WALL OR CEILING,EXPOSED IN UNFINISHED AREAS E-0.4 NREC <br /> ELECTRICAL RISER ____ �o k 45932 <br /> RACEWAY CONCEALED BELOW FLOOR ,n. <br /> E-2.1 LIGHTING PLAN AGISTER <br /> `s`S/ONAL <br /> GROUND FLEXIBLE CONDUIT FIXTURE WHIP WITH CONDUCTORS 3012023 <br /> E-3.1 POWER PLAN <br /> A-1,3,5 BRANCH CIRCUIT WIRING SHOWING CIRCUIT HOME RUN TO PANELBOARD. <br /> 30A/3P CIRCUIT BREAKER PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT. E-4.1 MECHANICAL POWER PLAN Key Plan <br /> o— NUMBER INDICATES TRIP SETING AND NUMBER OF <br /> 400AF/300AT POLES RACEWAY TURNING UP E-5.1 ONE-LINE DIAGRAM&FEEDER SCHEDULES <br /> _5-b_ ADJUSTABLE TRIP CIRCUIT BREAKER <br /> RACEWAY TURNING DOWN E-6.1 PANEL SCHEDULES <br /> 40000AS/300AF NUMBERS INDICATE FRAME SIZE/TRIP SETTING CIRCUIT CONTINUATION <br /> FUSED DISCONNECT SWITCH —LV— LOW VOLTAGE WIRING <br /> NUMBERS INDICATE SWITCH SIZE/FUSE SIZE <br /> PNL m JUNCTION BOX <br /> PANELBOARD PB PULL BOX <br /> CURRENT TRANSFORMER(CT) <br /> V CABLE TO BUS CONNECTION <br /> COVER SHEET <br /> Y o AUTOMATIC TRANSFER SWITCH(ATS) AND GENERAL <br /> <am> FEEDER TYPE-REFER TO FEEDER SCHEDULE ON INFORMATION <br /> ONE-UNE <br /> W3 UTILITY METER <br /> ® BRANCH CIRCUIT METER <br /> Scala: NONE <br /> CEI Project No: 230312 <br /> @-3 FEEDER METER <br /> Date: 3.7.2023 <br /> D SURGE PROTECTIVE DEVICE(SPD) Designed: J. MAXWELL <br /> XX,XXX AVAILABLE SYMMETRICAL FAULT CURRENT IN AMPS Drawn: R. FROGGEChecked: B. MAXWELL <br /> Sheet Number <br /> E-0 . 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.