My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3726 BROADWAY MOUNTAIN PACIFIC BANK 2023-09-15
>
Address Records
>
BROADWAY
>
3726
>
MOUNTAIN PACIFIC BANK
>
3726 BROADWAY MOUNTAIN PACIFIC BANK 2023-09-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2023 9:24:40 AM
Creation date
9/14/2023 6:09:01 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
3726
Tenant Name
MOUNTAIN PACIFIC BANK
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NEUD ORFER � � <br /> ENGINEERS <br /> AN Ein:tegra COMPANY WW. <br /> W NEUDDRFERENGI NEERS.COM <br /> Terms and Abbreviations <br /> Project: Mountain Pacific Bank Office TI <br /> 3726 Broadway Ave <br /> Everett, WA 98201 <br /> HVAC Heating Ventilation and Air Conditioning SAT Supply Air Temperature <br /> HWS Heating Water Supply S.F. Service Factor <br /> HWR Heating Water Return Schedule Design data obtained from the <br /> HX Heat Exchanger (sched) mechanical prints' schedule of <br /> HZ Hertz, cycle per second equipment. <br /> I.D. Inside Diameter SCR Silcon Controlled Rectifier <br /> in. inches Speed Controller <br /> in.w.g. inches of water gauge SF Supply Fan <br /> Kfactor Correction factor to the free area need to SFD Smoke/Fire Damper <br /> calculate CFM. SP Static Pressure <br /> KW Kilowatts Spec(s) Specifications <br /> LAT Leaving Air Temperature sq.ft. square feet <br /> LWG Low Wall Grille Submittals Submitted data on equipment <br /> LWR Low Wall Register (subs) capabilities. <br /> LWT Leaving Water Temperature Suct. Suction <br /> MAU Make-up Air Hangling Unit SWG Sidewall Grille <br /> MAX Maximum Flow Requirements for DDC SWR Sidewall Register <br /> MBH Mega BTUs per hour(1 MBH=1,000BTUH) TAB Test; Adjust; and Balance <br /> MIN Minimum Flow Requirements for DDC Tach Tachometer <br /> N/A Not Available Tech Technician <br /> N/S Not Shown or Specified TSP Total Static Pressure: Difference <br /> OA Outside Air between the entering and leaving <br /> OBD Opposed Blade Damper static pressure of a fan. <br /> O.D. Outside Diameter TP Traverse or Test Point <br /> PD Pressure Drop. TU Terminal Unit <br /> PH Phase UH Unit Heater <br /> PHC Preheat Coil VAV Variable Air Volume; box that <br /> Prim. Primary contains a motorized damper that <br /> PSI Pounds per Square Inch modulates airflow. <br /> RA Return Air VD Volume Damper <br /> RAT Return Air Temperature VFD Variable Frequency Drive <br /> RF Return Fan Velgrid Instrument that reads used to read <br /> RH Relative Humidity velocity in feet per minute. <br /> RHC Reheat Coil VP Velocity Pressure <br /> RPM Revolutions per Minute VVT Variable Volume Terminal <br /> RTU Roof Top Unit W.C. Water Column <br /> RVA Rotating Vane Anemometer-reads W.G. Water Gauge <br /> air velocity in feet per minute WB Wet Bulb <br /> SA Supply Air <br />
The URL can be used to link to this page
Your browser does not support the video tag.