Laserfiche WebLink
• GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION,LOAD CENTER,AND/OR SOLAR MODULE SPECIFICATIONS <br /> DISCONNECTS.DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ AMBIENT TEMPERATURE SPECIFICATIONS <br /> (AUTHORITY HAVING JURISDICTION).PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE TEMPERATURE #OF Lumio <br /> CODES. MANUFACTURER/MODEL# VMP IMP VOC ISC COEFFICIENT <br /> • WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN RECORD AMBIENT TEMP CONDUCTOR OF VoC MODULES <br /> TO INVERTER. LOW TEMP (HIGH TEMP 2%) TEMPERATURE HANWHA Q CELLS Q.PEAK DUO <br /> • PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE RATE BLK ML-G10+/t(400W) 38.09 10.50 45.55 11.07 -0.27%/K 22 <br /> PROTECTED IN A CONDUIT,RACEWAY,OR ARMORED PROTECTIVE SHEATHING(NEC 250.64). <br /> • THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE -5° 26' 90' MODULE DIMENSION 74.0"L x 41.1"W x 1.26"D <br /> NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. <br /> • ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC INVERTER SPECIFICATIONS <br /> 300.6 C1,310.8 D). SERVICE INFO. NOTE-EQUIPMENT RATED AT 75 DEGREES NOMINAL OUTPUT NOMINAL OUTPUT <br /> • ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. MANUFACTURER/MODEL# QUANTITY VOLTAGE CURRENT <br /> • ALL CONDUIT SHALL BE EMT 3/4"IN DIAMETER UNLESS OTHERWISE STATED. UTILITY PROVIDER: SNOPUD ENPHASE ENERGY <br /> MAIN SERVICE VOLTAGE: 240V 22 240 VAC 1.21A <br /> MAIN PANEL BRAND: N/A INTERCONNECTION IQ8PLUS-72-2-US <br /> MAIN SERVICE PANEL: (N)200A 120%RULE-NEC 705.12(b)( )(3 2) <br /> NOTE: MAIN CIRCUIT BREAKER RATING: (N)200A NOTE:THE AC DISCONNECT IS LOCATED <br /> 3/4"OR GREATER EMT CONDUIT MAIN SERVICE LOCATION: SOUTH-WEST UTILITY FEED+SOLAR BACKFEED WITHIN 10FT OF UTILITY METER <br /> RUN (7/8"ABOVE ROOF SURFACE) SERVICE FEED SOURCE: OVERHEAD 200A+40A=240A <br /> BUSS RATING x 120% AC DISCONNECT SHALL BE LOCATED <br /> 11 MICRO-INVERTERS IN BRANCH#1 SYSTEM SIZE:-22 x 40OW=8.800 kWDC 200A x 120%=240A WITHIN 10'OF UTILITY METER BI-DIRECTIONAL VERSION <br /> 22 x 290VA=6.380 kWAC UTILITY METER <br /> 1-PHASE,3-W, DESCRIPTION DATE REV <br /> 120V/24OV,60Hz INITIAL RELEASE 07/19/2023 UR <br /> • • . 44444-1 <br /> (N)ENPHASE IQ MSP UPGRADE: YES <br /> 44444) COMBINER BOX 4 TT <br /> _ _ X2-IQ-AM 1-240-4 <br /> ti ,V ti (IEEE1547:2018)[240V] <br /> 11 MICRO-INVERTERS IN BRANCH#2 <br /> 10A/15A <br /> • • • I (N)JUNCTION BOX <br /> (N)60A NON-FUSED,AC (N)MAIN <br /> 20A DISCONNECT,240 VAC <br /> _� _� _� L1 L1 200AE{ SERVICE PANEL, <br /> 200A RATED, <br /> — — 20A (N)MAIN BREAKER <br /> L1 L1 200A/2P,240V PROJECT NAME <br /> L1 L1 L2 L2 <br /> T U-)(22)ENPHASE ENERGY L L M IQ GATEWAY N N <br /> IQ8PLUS-72-2-US G 40A/2P LU U) M N <br /> MICRO-INVERTERS(240V) (N)40A/2P PV Q > O N <br /> (LOCATED UNDER EACH PANEL) — G — — N BREAKER > Q w 0 <br /> C) C) 0 � <br /> O <br /> BRANCH TERMINATOR Q-TERM _ _ _ _@�_ _ Q O <br /> FOR IQ SERIES(TYP.) J O LU <br /> p o00 � LU Uj <br /> > <br /> C O � (:T) cozy m <br /> EXISTING C <br /> A B GROUNDING LU Lo 0 <br /> SYSTEM (n <br /> O J ~ I— <br /> U LnLLI it — U <br /> _ U <br /> Qo w 0D � LU <br /> Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire z > Q Q O <br /> Wire Tag Conduit Wire Qty Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC (A) Correction Current(A) Size Type LU <br /> A OPEN AIR 2 12 AWG Q CABLE 90°C 30 1.00 N/A 30.00 11 1.21 1.25 16.64 06 AWG BARE CU <br /> B 3/4" EMT 4 12 AWG THWN-2 90°C 30 1.00 0.80 24.00 11 1.21 1.25 16.64 06 AWG THWN-2 <br /> SHEET NAME <br /> C 3/4" EMT 3 6 AWG THWN-2 90°C 75 1.00 1.0 75.00 22 1.21 1.25 33.28 06 AWG THWN-2 ELECTRICAL LINE <br /> DIAGRAM & <br /> CALCULATION <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> 1 ELECTRICAL LINE DIAGRAM WITH CALCULATION SHEET NUMBER <br /> SCALE: NTS PV-4 <br />