Laserfiche WebLink
Page 7 of 32 <br />Hilti PROFIS Engineering 3.0.85 <br />www.hilti.com <br />Company: Page: 4 <br />Address: Specifier: <br />Phone I Fax: E-Mail: <br />Design: 39451-2-H I LTI Date: 4/21 /2023 <br />Fastening point: <br />3 Tension load (Most utilized anchor 1) <br />Load Ps [lb] Capacity Pt [lb] Utilization Op = Ps/Pt [%] Status <br />Steel strength <br />144 <br />1,175 13 OK <br />Bond strength <br />144 <br />300 48 OK <br />3.1 Steel strength <br />Pts = ESR Value <br />refer to ICC-ES ESR-4143 <br />Pt,s > Ps <br />Results <br />Pts [lb] <br />Ps [lb] <br />1,175 <br />144 <br />3.2 Bond strength <br />Pt,b,Base = ESR Value <br />refer to ICC-ES ESR-4143 <br />Pt,b = Pt,b,Base - fred,E <br />fred,s * fred,Temp <br />Pt,b > Ps <br />Variables <br />c,,, [in.] <br />c, [in.] <br />Smin [in.] sir [in.] <br />Temperature [°F] <br />4.000 <br />- <br />4.000 - <br />68 <br />Results <br />Pt,b [lb] <br />Pt,b,Base [lb] <br />Ps [lb] fred,E <br />fred,S fred,Temp fred,TwolnOne <br />300 <br />300 <br />144 1.000 <br />1.000 1.000 - <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROMS Engineering ( c) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />4 <br />