Laserfiche WebLink
i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: B2109-079 Description: REMODEL SFR-NEW FLOORS, FIXTURES,ADD NEW <br /> BEDROOM/BATH TO <br /> Applied:9/24/2021 Approved: 1/8/2023 Site Address: 3409 FEDERAL AVE <br /> Issued: 1/9/2023 Finaled:8/15/2023 City,State Zip Code: EVERETT,WA 98201-4120 <br /> Status: FINALED Applicant: RAUL PONCE <br /> Parent Permit: Owner: BROADVIEW HOLDINGS LLC <br /> Parent Project: Contractor: EXPRESS INNOVATIONS <br /> Details: <br /> BASEMENT AND NEW LIGHTING THRU HOUSE AND REPLACE ROOF. <br /> REMODEL SFR-NEW FLOORS, FIXTURES,ADD NEW BEDROOM/BATH TO <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 2/1/2023 2/1/2023 BLDG 08-FRAMING RAKEEB KHAN CORRECTION eTRAKiT Inspection Request <br /> REQUIRED <br /> Notes: <br /> 1/30/2023 7:33 PM EXPRESS INNOVATIONS Ponce <br /> Call 253 202 4787 for ETA <br /> Contact Name:EXPRESS INNOVATIONS Ponce <br /> Site Address:3409 FEDERAL AVE <br /> Phone:2532024787 <br /> e-Mail:orlandooperezzl2@gmail.com <br /> No approved drawings on site.Unable to do a framing inspection. <br /> 2/13/2023 2/13/2023 BLDG 08-FRAMING RAKEEB KHAN CORRECTION eTRAKiT Inspection Request <br /> REQUIRED <br /> Notes: <br /> 2/10/2023 10:47 AM LILIANA AGUILAR HERNANDEZ <br /> Please call 253-202-4787 with ETA <br /> Contact Name:Orlando Ponce <br /> Site Address:3409 FEDERAL AVE <br /> Phone:2532049348 <br /> e-Mail:expresswa@outlook.com <br /> Plans call for 2x6 walls with R-21 insulation.Contractor framed 2x4 walls.Top plate at corner should overlap. Vertical fire blocking required 10' <br /> horizontal spacing.Rockwool ok to be used as fire blocking. Existing stairs do not comply with code requirements.See detail b on sheet A3.New <br /> footings poured prior to inspection will need to verify size of footing.Note concrete landing not in place verify at final.Walls removed at kitchen on <br /> main level.New beam in place.Provide engineering for new beam. New wall framing upstairs for existing bathroom and window infill.Plans only specify <br /> work in basement. <br /> Plans call for 2x6 walls with R-21 insulation.Contractor framed 2x4 walls.Top plate at corner should overlap. Vertical fire blocking required 10' <br /> horizontal spacing.Rockwool ok to be used as fire blocking. Existing stairs do not comply with code requirements.See detail b on sheet A3.New <br /> footings poured prior to inspection will need to verify size of footing.Note concrete landing not in place verify at final.Walls removed at kitchen on <br /> main level.New beam in place.Provide engineering for new beam. New wall framing upstairs for existing bathroom and window infill.Plans only specify <br /> work in basement. <br /> I <br /> Printed: Friday, 22 September, 2023 1 of 3 rk <br /> SUPERION <br />