My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-10-25
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 11:56:34 AM
Creation date
10/5/2023 12:58:07 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Step 9: Area of Refuge Emergency <br />Communication PASS FAIL N/A <br />1. 100% Tested - All devices associated with the Area of Refuge Emergency El El El <br />Communication shall be tested. <br />2. Operation - The area of refuge station shall provide for hands -free, two-way El El El <br />communication, provide an audible and visible signal to indicate communication <br />has occurred, and indicate to the receiver the location sending the signal. <br />3. Instructions - Instructions for the use of the two-way communications system, El El El <br />instructions for summoning assistance via the two-way communications system, <br />and written identification, including in braille, of the location shall be posted <br />adjacent to the two-way communications system. <br />4. Response - If the central control point is not constantly attended, it shall have a El El El <br />timed automatic communications capability to connect with a constantly attended <br />monitoring location where responsible personnel can initiate the appropriate <br />response. <br />5. <br />Quality and Clarity - Verify voice quality and clarity. <br />El <br />El <br />El <br />Step <br />10: Emergency Radio Communications <br />PASS <br />FAIL <br />N/A <br />1. <br />Emergency Radio Communications - Simulate the following trouble conditions: <br />El <br />El <br />El <br />• Signal Booster Trouble <br />• Antenna Failure <br />• Loss of Normal AC Power <br />• Failure of Battery Charger <br />• Low Battery Capacity <br />Step <br />11: System in Full Operation <br />PASS <br />FAIL <br />N/A <br />1. <br />Normal Condition - Ensure all systems are normal <br />El <br />El <br />El <br />2. <br />Off of Test - Ensure the Fire Alarm is off of test with the monitoring company. <br />El <br />El <br />El <br />3. <br />Record of Completion - Have the company complete and submit the Record of <br />El <br />El <br />El <br />Completion. <br />4. <br />Document Box - Have all manuals and the program placed in the document box. <br />El <br />El <br />El <br />5. <br />Knox Box - Keys for the FACP and pull station(s) shall be provided so they may be <br />El <br />El <br />El <br />placed into the Knox Box. <br />Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT C-5 4.13.2020 1 Page 10 <br />