Laserfiche WebLink
(E)POTTER <br />The Symbol of Protection <br />Features <br />• UL 268 7th Edition <br />• Low profile, less than 2 inches with the base <br />• Wide selectable sensitivity range of 1.0 to 3.7%/foot <br />• Sensor communicates sensitivity to control panel <br />• UL listed smoke calibration and sensitivity <br />• Optional locking tab to prevent unwanted removal <br />• Simple DIP switch address setting, no programming tool <br />required <br />• LED alarm indicator <br />• Product includes a 5 year warranty <br />• UUKL Listed for Smoke Control <br />Description <br />The Photoelectric Smoke Sensor is a listed Analog Addressable smoke <br />sensor compatible with fire alarm control panels that utilize the Potter <br />Addressable Device (PAD) protocol. The PAD200-PD is a low profile <br />smoke sensor with a wide sensitivity range. The sensor and base (not <br />included) are made of a durable plastic in an off-white color to blend <br />in with the ceiling. <br />The PAD200-PD has a sensitivity range of 1.0 to 3.7 % per foot and <br />is UL. The PAD200-PD features drift compensation and has built in <br />dirty detector warning as well as. The PAD200-PD and the control <br />panel communicate over a proven and robust digital communication <br />path and the system analyzes the information at the particular device. <br />The total polling speed is less than five (5) seconds, well under the UL <br />requirements. <br />The sensor is compatible with any of the PAD series sensor bases and <br />simply twists on. The PAD200-PD is addressed using DIP switches <br />in the rear of the sensor and can be easily programmed in the field <br />without special tools. <br />Setting the Address <br />Each addressable device on the SLC loop must have a unique address <br />from 1 to 127 to function properly. The address is set using DIP <br />switches. <br />Before connecting a device to the SLC loop, take the following <br />precautions to prevent potential damage to SLC or device. Verify the <br />following: <br />1. Power to the device is removed <br />2. Field wiring is correctly installed. <br />3. Field wiring has no open or short circuits. <br />PAD200-PD <br />Photoelectric Smoke Sensor <br />UL <br />LISTED <br />Technical Specifications <br />Operating Voltage <br />24 VDC <br />Detector Current Draw <br />300 µA <br />Alarm indicator <br />1 LED <br />Alarm set -point range <br />1.0 to 3.7 %/ft 3.6-12 %/m <br />Installation temperature <br />32 to 120 ° F / 0 to 49 ° C <br />range <br />Operating relative <br />0% to 93% (Non -condensing) <br />humidity range <br />Start-up time <br />Max. 1 sec. <br />Maximum number of <br />127 <br />addresses per loop <br />Maximum number of <br />lighted indicators in <br />30 <br />alarm per loop. <br />Color <br />Eggshell White <br />Weight (without base) <br />101g (3.56oz) <br />Dimensions (without <br />Height: 1.35 in (34mm) <br />base) <br />Diameter: 3.93 in (100 mm) <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830172 - REV A • 5/21 PAGE 1 OF 2 <br />