(E)POTTER <br />The Symbol of Protection <br />Air Velocity Ratings <br />The PAD200-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. <br />PAD200-PD <br />Photoelectric Smoke Sensor <br />The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD200-PD will operate even <br />though the LED may not illuminate. <br />Operation <br />The PAD200-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. <br />The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is <br />in an active status. The polling LED can be turned off if desired for less conspicuous operation. <br />The PAD200-PD with the PAD100-4DB or PAD 100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The <br />sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. <br />Sensor Sensitivity <br />The PAD200-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor <br />compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned <br />or replaced. <br />The PAD200-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to <br />the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. <br />NOTE. As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors <br />have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. <br />Spacing <br />The PAD200-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, <br />placement and special applications. <br />Compatible Bases <br />All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. <br />Device <br />Description <br />Stock No. <br />PAD100-4DB <br />4" Standard Base <br />3992731 <br />PAD100-61)B <br />6" Standard Base <br />3992732 <br />PAD100-IB <br />6" base with an isolator module included. <br />3992730 <br />PAD100-RB <br />6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC <br />3992728 <br />PAD 100-SB <br />6" base with sounder module included. Sound pattern is provided from external source. <br />3992729 <br />PAD100-SPKB <br />6" base with speaker included <br />3992762 <br />Ordering Information <br />Model <br />Description <br />I Stock No. <br />PAD200-PD <br />Photoelectric Smoke Sensor <br />3992770 <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830172 - REV A • 5/21 PAGE 2 OF 2 <br />