7. Documentation Cabinet - A documentation cabinet labeled "SYSTEM RECORD ❑ ❑ ❑ <br />DOCUMENTS" shall be installed at the system control unit or at another approved <br />location accessible only to authorized personnel. <br />Step 3: Maximum Load Test - Secondary Power PASS FAIL N/A <br />1. Manual Fire Alarm box - While on battery power, initiate an Alarm by pulling the ❑ ❑ ❑ <br />manual fire alarm box located at the FACP. <br />2. <br />90 Second Alarm Signal - Verify that the remote Central Station has received a fire <br />❑ ❑ ❑ <br />alarm signal within ninety (90) seconds. Let alarm continue during next step. <br />3. <br />5 - 15 Minute Test - Let alarm continue for a minimum of 5 minutes for general <br />❑ ❑ ❑ <br />occupant notification and 15 minutes for voice Evacuation. This is will give enough <br />time to verify operation of all notification appliances throughout the facility. <br />Audible Alarm Notification Appliances: <br />PASS FAIL N/A <br />4. <br />Per Plans - Verify annunciators are installed per approved plans <br />❑ ❑ ❑ <br />5. <br />Audible Sound - Audible alarms devices must be 15 dBA above normal ambient <br />❑ ❑ ❑ <br />sound level in all occupiable areas of building. <br />6. <br />Signal Pattern - Audible signal pattern used to notify building occupants of the <br />❑ ❑ ❑ <br />need to evacuate shall be the standard alarm evacuation signal consisting of a <br />three -pulse temporal pattern. <br />7. <br />Mounting - Wall -mounted appliances shall have their tops above the finished floor <br />❑ ❑ ❑ <br />at heights of not less than 90 inches and below the finished ceilings at distances of <br />not less than 6 inches. Ceiling -mounted or recessed appliances shall be permitted. <br />8. <br />Combination Audible/Visible - Combination audible/visible appliances shall be <br />❑ ❑ ❑ <br />installed as per the requirements for a visible alarm notification appliance. <br />9. <br />Environment - Verify that all appliances as listed for the environment that they are <br />❑ ❑ ❑ <br />located. (walk-in coolers/freezers, etc.) <br />10. <br />Guards/Cover/ Lenses - Appliances subject to mechanical damage shall be suitably <br />❑ ❑ ❑ <br />protected by a guard, cover, or lenses that is listed for use with the appliance. <br />Visible Alarm Notification Appliances: <br />PASS FAIL N/A <br />11. <br />Per Plans - Ensure the cd matches what was indicated on the plans. <br />❑ ❑ ❑ <br />Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire INFORMATION HANDOUT C-5 4.13.2020 1 Page 3 <br />