Laserfiche WebLink
Application Operation <br /> The i064 life safety system is a powerful intelligent solution for small The front panel provides an <br /> to mid-sized buildings.Advanced analog technology delivers the easy-to-use operator's inter- <br /> benefits of flexible system installation,while a clean and easy-to- face, as well as all the neces- <br /> operatate user interface makes panel operation and system mainte- sary controls for front panel ® o O <br /> nance quick and intuitive. programming.A large back-lit 101, <br /> 80-character LCD displays <br /> The smart choice system status, event details, ® O <br /> Signature Series electronic addressing eliminates the tedium of and programming prompts. ® �u <br /> setting dipswitches,and automatic device mapping ensures that Large tactile control buttons 00 ° <br /> each device resides on the system at its correct location. Mean- are easy to see in low light ® ®®® 0 <br /> while, innovative programming features allow the system designer conditions, and bright multi- ® ® © <br /> 030 <br /> to customize powerful built-in features to precisely suit the needs color LEDs offer at-a-glance <br /> of the building owner. status indication. ® x M)E)® ❑ <br /> Flexibility built right in <br /> Two fully-programmable front panel switch/LED combinations pro- Control buttons <br /> vide an added measure of flexibility.Their slide-in labels take the <br /> mystery out of custom applications,and present a clean finished Button Description <br /> appearance. System Reset Initiates a system reset. <br /> ACK/Panel Silences the panel and remote annunciators during <br /> Silence an active trouble,supervisory,or alarm event and <br /> Perfect for retrofits acknowledges new event activations. <br /> The i064 is particularly well-suited to retrofit applications.All Signal Silence Alarm mode:Silences active notification appliances. <br /> connections are made over standard wiring—no shielded cable Pressing Signal Silence a second time turns NACs back <br /> required.This means that in most situations existing wiring can be on. <br /> used to upgrade a legacy control panel to i0-Series technology Drill Initiates a drill confirmation.Pressing drill a second time <br /> without the expense or disruption of rewiring the entire building. turns off the drill function. <br /> Remote Dialer:Disables or enables dialer. <br /> Signals with a difference Disconnect Dialer set to modem only:Disables or enables the <br /> i064 NACs are configurable to fully support the advanced signal- common alarm relay. <br /> ing technology of Edwards Genesis and Enhanced Integrity notifi- Left arrow Display mode:Moves the cursor to the left. <br /> Menu mode:Toggles between programming <br /> cation appliances.These devices offer precision synchronization of selections. <br /> strobes to UL 1971 standards. For Genesis devices,enabling this Right arrow Display mode:Moves the cursor to the right. <br /> feature allows connected horns to be silenced while strobes on Menu mode:Retrieves a programming option's sub <br /> the same two-wire circuit continue to flash until the panel is reset. menu and toggles between a programming option's <br /> selections. <br /> Clear-cut remote annunciation Up arrow Display mode:Advances to the previous event. <br /> Remote annunciation is a strong suit of the i064. Up to eight an- Menu mode:Moves the cursor up. <br /> nunciators can be installed on a single system. Compatible annun- Down arrow Display mode:Advances to the next event. <br /> ciators include a range of LED and LCD models that provide zone Menu mode:Moves the cursor down. <br /> or point annunciation,as well as common control capabilities. Enter Display mode:Displays selected event details. <br /> Menu mode:Retrieves a programming option's sub <br /> The i064 also supports graphic annunciation with optional graphic menu or jumps to the Save function in the menu. <br /> annunicator interface modules. Each interface provides common Entry mode:Enters the selected data into the system. <br /> control, indicators, and LED drivers. Consult the Ordering Informa- Cancel Display mode:Exits the detailed information display. <br /> tion section for details. Menu mode:Exits the current menu level. <br /> Entry mode:Clears the current entry. <br /> Menu Display mode: Enters the menu mode <br /> A complete line of accessories Menu mode:Exits menu mode <br /> The i064 life safety system is supported by a complete line of Space Enters a space,such as a space between words. <br /> intelligent detectors, modules and related equipment. Consult the Alphanumeric Entry mode:Pressing a button once enters the number <br /> Ordering Information section for details. keypad on the button.Pressing the button twice enters the <br /> secondary value. <br /> Programmable These buttons can be programmed to control outputs, <br /> buttons disable devices or unlatch system outputs. <br /> Page 2 of 8 DATA SHEE 85005-0131 <br /> Not to be used for installation purposes. Issue 4 <br />