My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1415 75TH ST SW HELION ENERGY 2023-12-11
>
Address Records
>
75TH ST SW
>
1415
>
HELION ENERGY
>
1415 75TH ST SW HELION ENERGY 2023-12-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2023 9:58:23 AM
Creation date
10/9/2023 10:43:49 AM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1415
Tenant Name
HELION ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DUCT LINE EQUIVALENTS SYMBOLS <br />SINGLE LINE <br />DOUBLE LINE <br />DESCRIPTION <br />90' ELBOW UP (SUPPLY) <br />90' ELBOW UP (RETURN/EXHAUST) <br />®—� <br />90' ELBOW DOWN (SUPPLY) <br />Z_ <br />z__;,� <br />90' ELBOW DOWN (RETURN/EXHAUST) <br />Z_ <br />K= <br />RADIUS ELBOW UP (SUPPLY) <br />RADIUS ELBOW UP (RETURN/EXHAUST) <br />RADIUS ELBOW DOWN (SUPPLY) <br />RADIUS ELBOW DOWN (RETURN/EXHAUST) <br />0— <br />CT-41 <br />ROUND DUCT UP (S/R/E) <br />C_ <br />ROUND DUCT DOWN (S/R/E) <br />�-/ <br />TURNING VANE ELBOW <br />RADIUS ELBOW, RECT <br />RADIUS ELBOW, ROUND <br />, 0 <br />I�� <br />TRANSITION (ROUND TO ROUND/ <br />RECTANGULAR TO RECTANGULAR) <br />P 10 <br />I�� <br />TRANSITION (RECTANGULAR TO ROUND) <br />` <br />RECT <br />SPIN -IN TAKEOFF <br />ROUND — <br />` <br />ROUND <br />ROUND <br />CONICAL TEE <br />NTEE <br />WITH TURNING VANES <br />BRANCH TAKEOFF, RECT <br />RECT <br />BRANCH TAKEOFF, ROUND <br />ROUND —� <br />RECT � <br />BRANCH TEE, RECT <br />RECT <br />ROUND <br />CONICAL SPIN -IN TAKEOFF <br />—T—ROUND <br />ROUND � <br />BOOT TEE <br />�7 <br />` \ <br />45' LATERAL <br />45' CONICAL LATERAL <br />R2 <br />ELEVATION CHANGE <br />RISE (R) OR DROP (D) <br />I-2 <br />AIR FLOW DIRECTION - SUPPLY <br />+� <br />+� <br />AIR FLOW DIRECTION - <br />RETURN OR EXHAUST <br />2—� <br />N <br />DUCT END CAP <br />.ten <br />FLEXIBLE DUCTWORK <br />1 <br />MANUAL VOLUME DAMPER <br />1 <br />R <br />REMOTE VOLUME DAMPER <br />FSD <br />�T <br />FSD <br />I_(�—� <br />FIRE/SMOKE DAMPER - PROVIDE ACCESS <br />T <br />FIRE DAMPER - PROVIDE ACCESS <br />MOD <br />MOTOR OPERATED DAMPER <br />BED <br />T <br />�Nj <br />BACKDRAFT DAMPER <br />7—�-2 <br />HUMIDIFIER <br />® <br />SUPPLY GRILLE OR DIFFUSER <br />N <br />RETURN/EXHAUST GRILLE <br />0 <br />ROUND DUCT <br />GENERAL <br />SYMBOL <br />ABBR DESCRIPTION <br />® <br />AD ACCESS DOOR IN CEILING <br />AD ACCESS DOOR IN WALL <br />oP xx'-xx° <br />BOP BOTTOM OF PIPE ELEVATION <br />CENTERLINE <br />xx'-xx° <br />CL-EL CENTERLINE OF PIPE ELEVATION <br />X <br />DETAIL OR ENLARGED PLAN, NUMBER FOR <br />X-X <br />DETAIL, LETTER FOR ENLARGED PLAN TAG <br />X <br />DETAIL/SECTION CALL -OUT <br />FE'EXT <br />EQUIPMENT MARK TYPE - (EG "EF", FOR EXHAUST <br />FAN) THEN UNIQUE IDENTIFIER "X" <br />DIFFUSER/GRILLE DESIGNATION - TYPE "-" TO <br />XXX <br />MATCH SCHEDULE THEN "XXX" FOR CFM <br />FLOW ARROW <br />iE xx'-xx° <br />IE INVERT PIPE ELEVATION <br />,rc1 <br />PITCH LEFT <br />.a rt� <br />PITCH RIGHT <br />DRAWING NOTE DESIGNATION <br />T_ <br />B, <br />TOP OF DUCT, BOTTOM OF DUCT <br />OP XX'-XX° <br />TOP TOP OF PIPE ELEVATION <br />CONTROLS <br />PI <br />PI <br />PRESSURE INDICATOR <br />n <br />TI <br />TEMPERATURE INDICATOR <br />is <br />TS <br />TEMPERATURE SENSOR <br />6 -a <br />T <br />WALL MOUNTED TSTAT WITH CONTROL LINE <br />PIPING <br />SYMBOL <br />ABBR <br />DESCRIPTION <br />/ <br />45' ELBOW <br />45' DOWN <br />90' ELBOW <br />UP <br />C <br />DN <br />DOWN <br />- <br />ALIGNMENT GUIDE <br />iE <br />ANCHOR <br />AUTOMATIC CONTOL VALVE (3-WAY) <br />AUTOMATIC CONTROL VALVE (2-WAY) <br />NBALANCING <br />VALVE <br />i <br />BV <br />BALL VALVE <br />BEV <br />BUTTERFLY VALVE <br />CHK <br />CHECK VALVE <br />GAS COCK <br />^r <br />GLOBE VALVE <br />GV <br />GATE VALVE <br />PRV <br />PRESSURE REDUCING VALVE <br />RV <br />RELIEF VALVE <br />SV <br />SOLENOID VALVE <br />NEEDLE ISOLATION VALVE <br />AUTOMATIC INTERLOCKED <br />Oro <br />2-WAY BUTTERFLY VALVE <br />T <br />BREAK <br />C <br />CAP <br />PLUG <br />0 <br />POC <br />POINT OF CONNECTION <br />PG <br />PRESSURE GAUGE <br />ROLLING 45 DOWN <br />REDUCER <br />REDUCING CONCENTRIC <br />REDUCING ECCENTRIC <br />0 <br />DRAWING NOTE DESIGNATION <br />SLEEVE <br />TEE DOWN <br />TEE <br />TH <br />THERMOMETER <br />gyp— <br />U <br />UNION <br />• <br />VERTICAL SLEEVE <br />VALVE IN PIPE RISE OR DROP <br />STR <br />WYE TYPE STRAINER <br />WYE TYPE STRAINER WITH VALVE AND <br />t•,(j <br />HOSE END <br />AAV <br />AUTOMATIC AIR VENT <br />—BFW— <br />BFW <br />BOILER FEED WATER <br />p <br />BUCKET STEAM TRAP <br />CA <br />CA <br />CONTROL AIR <br />—CHR— <br />CHR <br />CHILLED WATER RETURN <br />CHS <br />CHS <br />CHILLED WATER SUPPLY <br />—CR— <br />CR <br />CONDENSER WATER RETURN <br />—CS— <br />CS <br />CONDENSER WATER SUPPLY <br />FLANGE <br />FLEX <br />■ <br />FLOAT AND THERMOSTATIC STEAM TRAP <br />—FOR— <br />FOR <br />FUEL OIL RETURN <br />— FOS— <br />FOS <br />FUEL OIL SUPPLY <br />— FOV— <br />FOV <br />FUEL OIL VENT <br />—G— <br />G <br />NATURAL GAS <br />— HCR— <br />NOR <br />HIGH PRESSURE CONDENSATE RETURN <br />HG <br />HG <br />HOT GAS <br />—HPS— <br />HIPS <br />HIGH PRESSURE STEAM <br />HWR <br />HWR <br />HEATING WATER RETURN <br />—HWS— <br />HWS <br />HEATING WATER SUPPLY <br />— LCR — <br />LOP <br />LOW PRESSURE CONDENSATE RETURN <br />LEE <br />LPS <br />LOW PRESSURE STEAM <br />MAV <br />MANUAL AIR VENT <br />— MCR— <br />MCR <br />MEDIUM PRESSURE CONDENSATE RETURN <br />® <br />METER <br />REFER TO PLANS FOR METER SERVICE <br />—MG— <br />MG <br />MEDIUM PRESSURE NATURAL GAS <br />— MPS— <br />MPS <br />MEDIUM PRESSURE STEAM <br />PCR— <br />FOR <br />PUMPED CONDENSATE RETURN <br />RL <br />RL <br />REFRIGERANT LIQUID <br />—RS— <br />IRS <br />REFRIGERANT SUCTION <br />—RV— <br />RV <br />REFRIGERANT VENT <br />T <br />TEMPERATURE PRESSURE TEST PLUG <br />VB <br />VACUUM BREAKER <br />VENTURI <br />ABBREVIATIONS <br />AC AIR CONDITIONING UNIT <br />AFF ABOVE FINISHED FLOOR <br />AHU AIR HANDLING UNIT <br />AMS AIRFLOW MEASURING UNIT <br />B BOILER <br />BDD BACKDRAFT DAMPER <br />BOD BOTTOM OF DUCT <br />HOT BOTTOM <br />BTUH BRITISH THERMAL UNIT PER HOUR <br />CC COOLING COIL <br />OEM CUBIC FEET PER MINUTE <br />CHLR CHILLER <br />CLG CEILING <br />CNTFGL CENTRIFUGAL <br />CORD CONDENSER / CONDENSATE <br />CP CIRCULATING PUMP <br />CT COOLING TOWER <br />CU CONDENSING UNIT / CUBIC <br />CV CONSTANT VOLUME <br />CWP CHILLED WATER PUMP <br />D DRAIN <br />DB DRY BULB / DECIBEL <br />DEG DEGREE <br />DIA DIAMETER <br />DMPR DAMPER <br />ON DOWN <br />EA EXHAUST AIR <br />EAT ENTERING AIR TEMPERATURE <br />ECONO ECONOMIZER <br />EDH ELECTRIC DUCT HEATER <br />EER ENERGY EFFICIENCY RATIO <br />EF EXHAUST FAN <br />ELEC ELECTRIC <br />ELEV ELEVATION <br />ESP EXTERNAL STATIC PRESSURE <br />EAT ENTERING WATER TEMPERATURE <br />EXIT EXHAUST <br />EXT EXTERIOR / EXTERNAL <br />FCU FAN COIL UNIT <br />FD FIRE DAMPER / FLOOR DRAIN <br />FLTR FILTER <br />FPM FEET PER MINUTE <br />FSD FIRE SMOKE DAMPER <br />FT FEET <br />FTU FAN TERMINAL UNIT <br />FV FACE VELOCITY <br />GALV GALVANIZED <br />GPM GALLONS PER MINUTE <br />GWB GYPSUM WALLBOARD <br />HC HEATING COIL <br />HORIZ HORIZONTAL <br />HT HEAT TRACER <br />HVAC HEATING VENTILATINGAND AIR CONDITIONING <br />HX HEAT EXCHANGER' <br />TIN INDIRECT DRAIN / INSIDE DIAMETER <br />INCH <br />KW KILOWATT <br />LAT LEAVING AIR TEMPERATURE <br />LB LWT LEEAUVING WATER TEMPERATURE <br />MEN THOUSAND BTU PER HOUR <br />MECH MECHANICAL <br />M D MOTOROUNTOPERATED DAMPER <br />NO NORMALLY CLOSED / NOISE CRITERIA <br />NIC NOT IN CONTRACT <br />NO NORMALLY OPEN / NUMBER <br />NTS NOT TO SCALE <br />ODD ONPOSEDDCENTBLADE DAMPER <br />OD OUTSIDE DIMENSION OR DIAMETER <br />OSA OUTSIDE AIR <br />PP PRESSURE DROP / PUMPED DRAIN <br />PLENUM <br />POO POINT OF CONNECTION <br />PT POST -TENSION SLAB <br />RA RETURN AIR <br />RAC RETURN AIR CANOPY <br />REF REFERENCE <br />REV RELIEFO FAN <br />RH RELATIVE HUMIDITY <br />RV REFRIGERANT VENT <br />SA SUPPLY AIR <br />SENS SENSIBLE <br />SF SUPPLY FAN SQUARE FOOT <br />SL SOUND LINE INSIDE DUCT INSULATION ) <br />SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION <br />SP STATIC PRESSURE <br />SS STAINLESS STEEL <br />ST SOUND TRAP <br />TCV TEMPERATURE CONTROL VALVE <br />TDH TOTAL DYNAMIC HEAD <br />TOD TOP OF DUCT <br />TOS TOP OF STEEL <br />TP TOTAL PRESSURE <br />TSP TOTAL STATIC PRESSURE <br />TYR TYPICAL <br />UBD UPBLAST DISCHARGE <br />UH UNIT HEATER <br />UNO UNLESS NOTED OTHERWISE <br />VA VALVE <br />VAV VARIABLE AIR VOLUME <br />VD VOLUME DAMPER <br />VENT VENTILATION / VENTILATOR <br />VEL VELOCITY <br />W INSULATED DUCT / WATT / WIDE <br />WE WET BULB {TEMPERATURE) <br />WG WATER GAUGE <br />WT WEIGHT <br />(GENERAL NOTES <br />1. THE MECHANICAL SCOPE OF WORK SHALL INCLUDE WORK INDICATED ON <br />DRAWINGS. <br />2. VERIFY EXISTING CONDITIONS BEFORE COMMENCING WORK ON AN EXISTING <br />MECHANICAL SYSTEM. <br />3. VERIFY LOCATIONS AND DIMENSIONS OF EQUIPMENT AND COORDINATE WORK <br />PRIOR TO START OF CONSTRUCTION. <br />4. COORDINATE MECHANICAL WORK WITH OTHER TRADES TO ENSURE PROPER AND <br />ADEQUATE INTERFACE OF THEIR WORK WITH THE WORK OF THIS CONTRACTOR. <br />INSTALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO STRUCTURE <br />ABOVE. <br />5. ELEVATIONS ARE REFERENCED FROM FINISHED FLOOR, UNLESS NOTED <br />OTHERWISE. <br />6. THE MECHANICAL DRAWINGS ARE SCHEMATIC IN NATURE AND DO NOT ATTEMPT <br />TO SHOW ALL REQUIRED OFFSETS. REFER TO ARCHITECTURAL AND <br />STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. <br />7. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING CLEARANCES <br />FOR ELECTRICAL PANELS AND EQUIPMENT. OFFSET MECHANICAL WORK AS <br />REQUIRED. <br />8. MECHANICAL EQUIPMENT SHALL NOT BE USED FOR TEMPORARY HEAT DURING <br />CONSTRUCTION. <br />9. DUCTWORK SIZES SHOWN ARE INSIDE CLEAR. ADD APPROPRIATE DIMENSION <br />FOR INSULATION OR DUCT LINER TO OBTAIN 'TOTAL" DUCT SIZE. <br />VICINITY MAP <br />LEGAL DESCRIPTION <br />BEVERLY BERRY TRACTS DIV 2 BLK 000 D-02 LOT B JAG INVESTMENTS ESP REC <br />VOL 1 OF BSP'S PG 238 AF N09109175007 & AT NO 9109170098 BEING A PTN <br />OF LOTS 23 & 24 EXST PLAT <br />PARCEL NUMBER <br />00392200002302 <br />N <br />a � <br />W f <br />75TH ST <br />PROJECT LOCATION <br />NORTH ARROW <br />MECHANICAL DRAWING INDEX <br />SHEET DESCRIPTION <br />MOC1 LEGEND, DRAWING INDEX, VICINITY MAP AND GENERAL NOTES <br />M1.01 CALCULATIONS, ENERGY NOTES, AND MECHANICAL SCHEDULES <br />M2.01 PARTIAL FIRST FLOOR MECHANICAL PLAN <br />M4.01 MECHANICAL DETAILS <br />H <br />H <br />a <br />N �Zi aaaaaaa� <br />2 <br />0 <br />0 <br />J <br />C) <br />o <br />� <br />M <br />O <br />Z <br />N <br />Go <br />E <br />Q <br />fn rn <br />V <br />n3 <br />Z <br />m HF <br />O <br />NF <br />a nLU <br />J <br />to W <br />` <br />2 <br />W <br />> <br />2- W 3 <br />zLL .wJ <br />N <br />w OD , x w wx <br />O WW<o J <br />xap'z»av <br />zaxzox§zxz <br />J <br />wo <br />z~f ¢r~nO wZi¢ <br />w 3Q�Iz'Fo o <br />W 2aW<oV�Wfq< <br />U mW>z�WW~cc m <br />>z <br />¢_ o ' <br />Z v �s:)oo:5 m3:5u <br />Q <br />d <br />Q <br />} UH <br />ILLI E <br />Z <br />_U <br />X E <br />O <br />Z � <br />U E <br />_Z 7 <br />Q <br />Z <br />W <br />U <br />w <br />J <br />Drawn By UMC <br />Checked By RK <br />Original Issue Date 05/15/2023 <br />Job No. 9038 <br />Scale AS SHOWN <br />Sheet No. <br />M0.01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.