Laserfiche WebLink
ACCURATE SCALES WHEN PRINTED <br />AT 100% ON 11 X 17 (ANSI B) PAPER <br />The following provides typical requirements for one- and two-family residential projects designed to comply with <br />the 2018 International Residential Code (IRC). This document does not provide a detailed list of code requirements <br />and does not provide requirements for preparing designs complying with the 2018 International Building Code <br />(I BC). <br />See IRC Section R105.2 for building work that is exempt from requiring permits. All work is still required to <br />comply with the applicable requirements of the building codes; the designer is responsible to verify compliance. <br />Exempt work includes but is not limited to: <br />• Finish work that does not alter the building structure or egress routes and features, including: painting, papering, <br />tiling, carpeting, cabinets, counter tops, etc. <br />• One-story detached accessory structures with floor areas not exceeding 200 square feet. <br />• Window and door replacement, provided that the opening size does not change. <br />• Fences not exceeding 7 feet tall. <br />• Retaining walls not exceeding 4 feet tall (top of wall to bottom of footing), with no surcharge loads (e.g., roads or <br />buildings located above wall and within 2x distance of the wall height), or sloped surfaces above or below. Build <br />per manufacturer. <br />• Concrete or masonry walls used as fences and not exceeding 4 feet tall. Walls must be internally stable (i.e., <br />reinforced with a minimum 1-foot wide foundation, or maximum 4:1 height -to -width ratio). <br />• Playground equipment. <br />• Detached decks not exceeding 200 square feet and not more than 30 inches tall. <br />The 2018 IRC and 2018 IBC are adopted by the Washington Administrative Code (WAC) Title 51 and Everett <br />Municipal Code (EMC) Chapter 16.005 (effective 02/01/2021). WAC amendments to the cited code sections are <br />followed by "(WAC)". Design for one- and two-family residential buildings is permitted per IBC Section 101.2 and <br />IRC Section 101.2 (WAC). Residential buildings not complying with the limitations of these sections require design <br />in accordance with the IBC. In addition, limited or comprehensive structural design may be performed for building <br />designed using the IRC per Section R3011.3; additional requirements may apply. <br />The provisions of the IRC shall apply to new buildings, additions, alterations, and repairs, without requiring <br />compliance by the existing structure. See IRC Section R102.7.1(WAC). Note that unpermitted work previously <br />performed within the building, whether by the current of former owner, does not qualify as "existing" and must be <br />approved with a valid permit. See IRC Sections R1051, R105.4, R105.6, and R1131. <br />The following links may be used to view the building codes adopted in the state of Washington and the city of <br />Eve rett: <br />• IRC: 1 • - - • • 1 1 \ , • <br />• • - - • • , • <br />A. General Requirements <br />1. General: <br />a. Two complete sets of construction drawings. See IRC Section R1061(WAC). Do not submit original copies; <br />originals will not be returned. Sets should include at a minimum (as applicable): <br />i. Site <br />ii. Architectural <br />iii. Structural <br />b. Provide all drawings on a single standard sheet size (e.g.,11"x17", etc.); do not exceed 24"x36" <br />c. Drawings should be legible and good reproduction quality (IRC Section R10611). <br />d. Prepare drawings using recognized drafting standards for building construction (IRC Section R10611). <br />e. Prepare drawings using the approved scales. Use consistent scales where appropriate (e.g., same scale for all <br />architectural and structural plans, etc.). Scales should be: <br />ii. Site plans: engineering scale (e,g.,1"=10, etc.). <br />iii. Architectural and Structural plans: architectural scale (e.g., Y4=1'-011 <br />, etc.). <br />f. State the site address on all plans (IRC Sections R105.3(2) and R3191). <br />g. Provide a scope of work (SOW) statement describing the proposed project (IRC Section R105.3(1)). List key <br />project elements. Proposed future work should not be included. <br />h. List work requiring separate permits including but are not limited to: electrical, mechanical, plumbing, and fire <br />sprinklers. <br />2. Site Drawings: <br />a. Prepare per Planning Department requirements, and addition items stated herein. <br />b. Dimension lot setbacks (EMC and IRC Section R106.2), <br />c. Dimension building fire separation distances (IRC Sections R202 and R302). <br />d. Show means -of -egress from the building to the public way (IRC Section 3111). <br />e. State ground elevations adjacent to building foundations and retaining walls. Show sloping surfaces where <br />they occur; specify slope. <br />3. Building Drawings: <br />a. Architectural and structural construction. Provide separate drawings for each discipline where work is <br />significant. Proposed future work should not be included. See specific requirements in "Architectural" and <br />Structural" sections below. <br />b. Show entire house layout, including existing construction not included in the project. Detailed construction <br />information is not required for existing work that has been previously permitted. Existing construction should <br />show: <br />i. Walls, drawn at nominal thicknesses (e.g., 411 <br />, 6", etc.). <br />ii. Stairs, including width, handrails, and landings (dimension size). <br />iii. Doors, type, width, and swing direction. <br />iv. Windows, including emergency egress windows and sizes. <br />v. Non -habitable spaces (e.g., garages, unfinished basements, attics, crawls spaces, storage rooms, etc.) <br />vi. Label use of each room (e.g., kitchen, bedroom, etc.). <br />vii. Exterior decks, porches, and balconies, including stairs, guards, and landings. <br />viii. Locations of all appliances (e.g., stove, furnace, W/D, etc.). <br />ix. Smoke and carbon monoxide alarms. <br />x. Sprinkler system. <br />c. Perform review of City of Everett and Snohomish County records to verify permitted condition of the house <br />and identify unpermitted work. Show unpermitted work as new construction, not existing. Detailed information for <br />construction is required. See IRC Sections R1051, R105.4, R105.6, and R1131. Available records may be viewed <br />using the following links: <br />City of Everett: htT,L/lfbortal.everettwa.aoovv/WebLink/CustomSearch.aspx? <br />Search Name=AddressSearch&id=1&cr=1 <br />ii. Snohomish County: <br />htT,L/snohom ishcou ntvwa.aoovv/5167/Assessor <br />4. Other: <br />a. Structural calculations (IRC Section R3011.3) <br />b. Supporting documentation (e.g., proprietary building systems, alternative materials per Section R10411, etc.). <br />See IRC Section R105.3(7). <br />c. Adult Family Home (AFH) forms. Forms may be obtained using the following link: <br />htT,L/everettwa.aoovv/DocumentCenter/View/108/Adult-family-home-checklist-PDF <br />B. Architectural Requirements <br />1. General: <br />a. Plans: Floor, basement, reflected ceiling, and roof. <br />b. Exterior elevations: Show each side of building where work is occurring. May be omitted if exterior work is not <br />proposed. <br />c. Building sections: Provide complete sections through building to clarify proposed construction. Minimum one <br />in each principal building direction (more as required). May be omitted for small projects and renovations. <br />d. Local sections, details, general notes, material requirements, and other information as required to specify the <br />proposed construction. <br />e. Plan and elevation dimensions: Include all dimensions, elevations, slopes, etc. required to define the proposed <br />work. Story heights should not exceed the limits of IRC Section R3011.3. The total building height should not <br />exceed the limits of the EMC; contact the Planning Department for additional information. <br />2. Room (IRC Sections R304 and R305): <br />a. Label use of each room. <br />b. Room dimensions and area <br />c. Ceiling height(s) and slope(s). <br />PROJECT NUMBER <br />21-164-L . <br />DATE DRAWN: 2021-SEP-17 <br />DRAWN BY: MA <br />REVISION HISTORY <br />revA:2021-SEP-19 MA <br />revB:2021-OCT-27 MA <br />revC:2021-NOV-29 MA <br />revD:2021-DEC-15 MA <br />PERMIT AUTHORITY <br />CITY OF EVERETT <br />PERMIT OFFICE <br />EVERETT PERMIT SERVICES <br />3200 Cedar Street <br />2nd Floor <br />Everett, WA 98201 <br />Phone: (425) 257-8810 <br />PermitServices@everettwa.gov <br />o <br />J � 0 <br />CU o <br />0 <br />UI = 0 <br />> U o <br />W J <br />CID <br />1 0 <br />MQo <br />m � W ILL0 0 r_ <br />LU O <br />00 00 <br />W r-,:. <br />QC7) �eN <br />U W Qm` <br />LU 0 <br />0 � Z��� <br />z LU -- N <br />W <br />J QwL <br />of z <br />J w Z O <br />X Q �a�Q0 <br />W H 00 <br />w 0 W J <br />0 o Zo�mN <br />cn Q w ; o <br />w -0 <br />W °C .� N 0 <br />V CO .. [-- CO <br />CV Z 0 0 <br />0 Z .. _o Lo <br />Q «i~O0 <br />0 �Wa o <br />W =00cou <br />C)aWZ� <br />_ o <br />W J > W <br />J �WNa <br />Vi cn_JclR <br />* E <br />L" c E <br />Q U <br />Q CU O <br />a <br />w � <br />U) <br />(D o 21 ca <br />z (n U <br />LL <br />Y � <br />o 0- <br />z o@) <br />O co 0-) <br />� <br />U X cq C6 <br />W 0 N - <br />a m o 0- <br />0 iM <br />a_ <br />SHEET TITLE <br />CITY OF EVERETT <br />SHEET DISCIPLINE <br />Am7 <br />ANSI B <br />Y <br />J <br />Y <br />0 <br />O <br />J <br />>J_ <br />Q <br />_ <br />X <br />w <br />0 <br />Z <br />Lll <br />Y <br />J <br />Y <br />0 <br />0 <br />0 <br />J <br />D <br />0 <br />0 <br />w <br />w <br />Li- <br />Q <br />0 <br />Z <br />0 <br />Z <br />w <br />w <br />d <br />w <br />Ir <br />w <br />Q <br />w <br />Ir <br />w <br />0 <br />Z <br />w <br />0 <br />w <br />0 <br />w <br />_ <br />0 <br />w <br />w <br />J <br />m <br />Q <br />J <br />> <br />Q <br />Q <br />0 <br />w <br />J <br />Li- <br />w <br />J <br />Q <br />X <br />w <br />O Cw <br />Z> <br />�Ir <br />Q w <br />Cl) <br />0� <br />ZCl) <br />Q� <br />w = <br />J LD <br />0 Ir <br />Cl) J <br />oQ <br />0 N <br />Z CN <br />w @ <br />w(D <br />00 <br />cm 0 <br />ACCURATE SCALES WHEN PRINTED <br />AT 100% ON 11 X 17 (ANSI B) PAPER <br />