i8G►
<br />EGRESS
<br />COIS6)
<br />SAFETY GLASS/R308.4
<br />0 TO BE PROVIDED IN DOOR ASSEMBLIES AND WITHIN A 24" ARC OF HINGED EDGE OF A DOOR
<br />& GLAZING IS LESS THAN 60" A.F.F.
<br />• WITHIN ENCLOSURES FOR TUBS & SHOWERS WHEN BOTTOM OF GLASS IS LESS THAN 6011
<br />ABOVE THE STANDING SURFACE.
<br />• WHEN GLAZING IS LESS THAN 18" ABOVE THE FLOOR AND HAS MORE THAN 9 SQ. FEET OF
<br />AREA.
<br />• GLAZING AT STAIRWAY LANDINGS AND WITHIN 6011 HORIZ., OF SUCH LANDINGS WHEN
<br />BOTTOM EDGE OF GLAZING IS LESS THAN 60 ABOVE FINISHED FLOOR.
<br />• SKYLIGHTS TO COMPLY WITH SECTION R308.6.
<br />LANDINGS PER R311.3
<br />• STAIR WELL ILLUMINATION PER R303.6
<br />o A 3611 BY OPENING WIDTH (3611 MIN.) CONCRETE STOOP IS REQUIRED OUTSIDE ALL EXTERIOR
<br />DOORS
<br />FURNACE/WATER HEATER
<br />• STEEL HWT TO COMPLY WITH ASHRAE 9OA-80 & LABELED. TO BE EQUIPPED WITH A
<br />PRESSURE & RELIEF VALVE W/3/4" COPPER OR GALVANIZED STEEL OVERFLOW VENT PIPE
<br />PLUMBED TO OUTSIDE .& SEISMIC STRAPS FOR HORIZ. FORCES TOP AND BOTTOM, SHALL BE
<br />PROVIDED WITHIN THE UPPER AND LOWER 1/3RD OF ITS VERTICAL DIMENSION. THE LOWER
<br />STRAP SHALL NOT BE LESS THAN 4" ABOVE ITS CONTROLS.
<br />• INSULATE HWT WITH R-16 WRAP & TO SIT ON R-10 RIGID WHEN PLACED ON CONCRETE.
<br />• HVAC ABOVE FLOOR DUCTING TO BE 26GA.
<br />• HVAC UNIT TO COMPLY WITH 2O18 W.S.E.C.& LABELED WITH A PERFORMANCE RATING.
<br />• PILOTS, BURNERS, SWITCHES TO BE 18" AFF
<br />• COMBUSTION AIR REQUIREMENTS SHALL CONFORM TO THE REQUIREMENTS OF CHAPTER 7
<br />OF THE INTERNATIONAL MECHANICAL CODE (IMC).
<br />• PROTECT MECHANICAL FROM IMPACT W/ BOLLARD WHEN LOCATED IN GARAGE.
<br />VENTILATION / 2018 W.S.E.C.
<br />• RANGE/COOKTOP TO BE VENTED TO EXT. WITH A,100 CFM MIN IF OVER 400 CFM USE
<br />MAKEUP AIR VENT.
<br />• BATH/LAUNDRY 50 CFM MIN (USE 80)
<br />• VENT ALL EXHAUST TO OUTSIDE PROVIDE 2XBLOCKING EACH SIDE OF FAN. HOLD BLOCKING
<br />1/4" UP FORM GWB
<br />• WHOLE HOUSE VENT LOCATION AT 120 CFM. SEE WSEC PAGE FOR SPECIFIC TYPE AND
<br />OPERATION/CONFIG.
<br />TUB, SHOWER, W/C:
<br />• PROVIDE SOLID BLKING BEHIND ALL BATH ACCESSORIES
<br />• SHOWER TO COMPLY WITH R 30Z2
<br />• WATERPROOF BACKING +7211MIN. ABOVE DRAIN INLET.R702.4.2
<br />• PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES SHALL BE PROVIDED FOR SHOWERS
<br />AND TUB/SHOWER COMBO @ 2.5 GPM MAX.
<br />• PROVIDE SAFETY GLASS ON ALL ENCLOSURES.
<br />• ALL PLUMBING FAUCETS TO HAVE A 2.2 GPM FLOW RESTRICTOR.
<br />• W/C TO USE 1.6 GALLON MAX. PER FLUSH. SECTION P2903
<br />• TOILET PAPER DISPENSERS TO BE MOUNTED @ 2711 AFF. (TY1P.)
<br />• ALL TOWEL BARS MOUNTED @ 4211 AFF.
<br />ATTIC ACCESS/R807.1
<br />• 22X3011 MIN. CLEAR OPENING, WITH 30" MIN. CLEAR HEADROOM.
<br />• LOCATED IN HALLWAYS OR OTHER READILY ACCESSIBLE AREAS,INSULATE AND WEATHER-
<br />STRIP
<br />R 310 EMERGENCY ESCAPE AND RESCUE OPENINGS
<br />EVERY BEDROOM SHALL BE PROVIDED WITH AN EGRESS WINDOW IAW CODE,
<br />• MIN. OPENING AREA a 5.7 SF (5.0 SF AT GRADE FLOOR OPENINGS).
<br />• MIN. OPENING HEIGHT = 24" CLEAR.
<br />• MIN. OPENING WIDTH = 20" CLEAR.'
<br />• MAX. SILL HEIGHT = 44" FROM FLOOR TO BOTTOM OF CLEAR OPENING.
<br />• NOTE: OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE
<br />USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE.
<br />SMOKE ALARM LOCATIONS R314.3 (2018 IRC)
<br />SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS:
<br />• IN EACH SLEEPING ROOM.
<br />• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.
<br />• ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE
<br />ATTICS AND NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. IN DWELLINGS OR
<br />DWELLING UNITS WITH SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN THE
<br />ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE UPPER LEVEL SHALL SUFFICE FOR
<br />THE ADJACENT LOWER LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE FULL
<br />STORY BELOW THE UPPER LEVEL.
<br />• SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE
<br />DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS
<br />WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY EOrht2N 8314.3.
<br />•SMOKE ALARMS SHALL BE INTERCONNECTED AS INDICATED IN SECTION R314.3
<br />• THE POWER SOURCE FOR SMOKE ALARMS SHALL COMPLY WITH SECTION R314.4
<br />• CARBON MONOXIDE ALARMS SHALL ALSO BE INSTALLED OUTSIDE OF EACH SEPARATE
<br />SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS (SECTION R3151, R315.3)
<br />FLAAR PLA"Ol ffi!
<br />-5 ALSO REVIEW SPECIFICATIONS, GENERAL NOTES, AND TYPICAL WALL SECTION.
<br />• EXTERIOR STUD WALLS 2X6 DF#2 @16" O.C. W/ DBL 'TOP PLATE & LAPPED 48" MIN. R-21 IN -
<br />WALL BATT INSULATION W/VAPOR BARRIER.
<br />• INTERIOR,WALLS SHALL BE 2X4 DF#2 STUDS AT 16" O.C. UON.
<br />• HEADERS:. 4X10.WITH' R-10 RIGID -INSULATION UON.
<br />• GARAGE EXTERIOR STUD WALLS CAN BE 2X4 @ 16" O.C. (PER BUILDER)
<br />• PROVIDE TEMPORARY BRACING AS REQUIRED UNTIL ALL CONNECTIONS AND STIFFENERS
<br />HAVE BEEN INSTALLED.
<br />• ALL FRAME NAILING TO COMPLY WITH TABLE R602.3(1), 2018 I.R.C.
<br />• ALL FASTENERS OR NAILS CONTACTING PRESSURE TREATED MATERIAL SHALL BE HOT -DIP
<br />GALVANIZED PER ASTM A153.
<br />• REFER TO ELEVATIONS FOR TOP OF WALL PLATE HEIGHTS.
<br />• REFER TO FRAMING PLANS FOR BEAMS & HEADERS (MATCH EXIST. UON) PROVIDE SOLID
<br />BLOCKING OVER BEAMS & BEARING WALLS /R502.
<br />• BLOCK ALL APA RATED SHEATHING EDGES AND NAIL WITH 10D AT 6" O.C. AT PANEL EDGE
<br />AND 12" O.C. IN THE FIELD (TYR) UON ON SHEAR WALL SCHEDULE.
<br />• ENGINEERED LUMBER SPECIFIED SHALL MEET OR EXCEED DESIGN STRESS, INSTALL PER
<br />MFG. RECOMMENDATIONS UON.
<br />*ALL HANGERS / STRAPS' BY SIMPSON OR EQUAL. Z-MAX TRIPLE HDG FOR ALL PT AND
<br />EXTERIOR APPLICATIONS.
<br />• DENOTES SOLID POST OR DBL STUD POST LAMINATED TOGETHER W/16D (2) !:EACH END AND
<br />12" O/C STAGGERED, UON..
<br />• FIRE BLOCK ALL PLUMBING PENETRATIONS, PROVIDE IN -WALL HORIZONTAL FIRE BLOCKING
<br />AT 10'-0 OR MIDSPAN IF LESS THAN 20' BALLOON FRAMED WALL FOR ALL WALLS CAVITIES,
<br />BOX BEAMS, SOFFITS AND SIMILAR THAT EXCEED 10 FEET HIGH. ALL CONCEALED VOIDS TO
<br />BE FIRE AND DRAFT STOPPED PER SECTION R602.8, 2018 I.R.C.
<br />• ALL WINDOWS SHALL COMPLY W/ W.S.E.C., BUILDER TO VERIFY ROUGH OPENINGS.
<br />• PROVIDE 26 GA GALV SHEET METAL FLASHING ABOVE WINDOWS AND DOORS, LAP BUILDING
<br />PAPER OVER.
<br />• FINISH CEILINGS WITH 1/211 GWB MIN. OR 5/8" TYPE X WHERE JOISTS ARE SPACED GREATER
<br />THAN 16". ENTIRE GARAGE SHALL BE 5/8" TYPE-X GWB.
<br />• PREFABRICATED FIREPLACES, CHIMNEYS AND RELATED COMPONENTS TO BEAR UL.SEAL OF
<br />APPROVAL AND TO BE INSTALLED PER PER MANUFACTURE'S SPECIFICATIONS.
<br />• PROVIDE ELECTRIC ILLUMINATION AT OUTSIDE DOORS SWITCHED FROM INSIDE OF SAME
<br />DOOR.
<br />• PROVIDE ELECTRIC ILLUMINATION AT STAIRWAYS W/ (6) OR MORE RISERS, SWITCHED AT
<br />EACH FLOOR LEVEL.
<br />• HVAC DUCTS MUST NOT DISPLACE REQUIRED INSULATION AT ANY GIVEN LOCATION,
<br />PROVIDE REQUIRED FLOOR OR CEILING INSULATION ON UNHEATED SIDE OF DUCTS
<br />INSTALLED IN JOIST OR RAFTER CAVITIES9.
<br />ICSES
<br />CONSULTING STRUCTURAL ENGINEERING, INC.
<br />6311 97th Avenge NE - Seattle. WA 98115
<br />206-527-1288
<br />Existing drawings were pulled from the structural set by Chris Covington, PE. The above
<br />stamp only refers to the hold
<br />down revision notes in red. No other portion of this project
<br />has been reviewed by CSES.
<br />See the included sheet S 1 for details
<br />- ENLARGE ROUGH OPENING TO FIT A WINDOW THAT MEETS EGRESS
<br />- INSTALL WINDOW THAT MEETS EGRESS
<br />- REMOVE WINDOW
<br />n
<br />U
<br />- COMPLETELY FILL IN FRAMED ROUGH OPENING
<br />- SHEETRO K PRIME PAINT TO MATCH
<br />- REMOVE WINDOW
<br />�4
<br />- COMPLETELY FILL IN FRAMED ROUGH OPENING
<br />- TILE TO MATCH SE H 0
<br />- REMOVE SIDING FROM WALL
<br />�5
<br />- INSTALL 5/8" TYPE-X FIRE -RATED G.W.B TO GARAGE FACING SIDE OF WALL
<br />- TAPE, FLQAT. PRIM
<br />- FRAME PARTITION WALL FROM TOP OF THIS WALL TO UNDERSIDE OF ROOF
<br />PLYWOOD
<br />- FRAME AN ACCESS ROUGH OPENING IN THE WALL TO PROVIDE ACCESS TO
<br />©
<br />THIS NEWLY CLOSED -OFF ATTIC SPACE.
<br />- INSTALL SOLID FIREBLOCKING BETWEEN RAFTERS AND NEW PARTITION WALL
<br />- INSTALL 5/8" TYPE-X FIRE -RATED G.W.B, ON GARAGE FACING SIDE OF WALL
<br />- FIRE SEAL A P N TRAT WITH FIRE -RATED CAULKING
<br />- FRAME A CEILING IN THE GARAGE SUFFICIENT TO ALLOW FOR 5/8" TYPE-X
<br />FIRE -RATED G.W.B TO BE HUNG AS A LID OVER THE GARAGE SPACE. THIS
<br />WOULD ELIMINATE THE NEED FOR NOTE # 6.
<br />O
<br />- ENSURE THAT AN ATTIC ACCESS IS FRAMED INTO THE GARAGE CEILING
<br />- ENSURE THAT THERE IS SUFFICIENT ATTIC VENTILATION BY CUTTING AWAY
<br />MOST OF THE UPPER ATTIC GABLE WALL ON THE EXISTING HOUSE SO THAT AIR
<br />FLOW IS UNOBSTRUCTED BETWEEN THE HOME ATTIC AND THE GARAGE ATTIC.
<br />-REMOVE THIS PLATE GLASS WINDOW
<br />®
<br />- ROTATE IT 90 DEGREES AND ENSURE IN IT IS ABOVE THE MIN HEIGHT
<br />THRESHOLD FOR TEMPERED GLASS 08" ABOVE F.F.) OR REPLACE IT WITH
<br />TEMPERED GLASS.
<br />THIS BEAM NEEDS TO BE SPECIFIED BY ENGINEERING
<br />- THE BEAM SUPPORTS 2X8 JOISTS THAT PROVIDE THE FRAMED CEILING IN THE
<br />KITCHEN AND LIVING ROOMS.
<br />- SUGGEST A TALLER BEAM THAT IS PLACED ON TOP OF THE WALL PLATES AND
<br />O
<br />HAVE THE CEILING JOISTS CUT AND HANGERED TO THIS NEW BEAM. THIS
<br />WOULD CREATE A FLAT/CONTINUOUS CEILING FROM KITCHEN TO LIVING
<br />SPACES.
<br />- THERE IS NO POINT LOAD PATH TO GROUND UNDER THE ENDS OF THE
<br />SEE WHAT THE PERMIT AUTHORITY WILL ALLOW TO'REMAIN UNTOUCHED.
<br />RECOMMEND:
<br />- REMOVE THE ENTIRE STAIRWAY
<br />- CHANGE THE DOOR SWING TO OPEN INTO THE HALLWAY
<br />- REMOVE THE FLOOR SYSTEM UNDER THE PANTRY AND PART OF THE LOWER
<br />•10
<br />PANTRY WALL BETWEEN THE PANTRY AND CLOSET #1
<br />- CONSTRUCT NEW STAIRS (F.F. TO F.F. IS 971/4")
<br />BUILD THE BOTTOM PLATFORM TALL ENOUGH TO ALLOW THE UPPER STAIRS TO
<br />STOP WITHOUT EXTENDING PAST THE END OF THE WALL
<br />- BUILD A SHELF PLATFORM IN THE PANTRY THAT'IS FINISHED AT MIN. 6'-8"
<br />HEADROOM CLgA86b10E M NEW STAIRS.AS PER IRG 2Q18 CODE
<br />11 I
<br />INSTALL SMOKE DETECTORS IN EACH BEDROOM.
<br />BASEMENI
<br />- REMOV XISTING WINDOW
<br />O
<br />- ENLARG ROUGH OPENING TO INCLUDE WIDER AND SUFFICIENTLY SPECIFIED
<br />HEADER.
<br />- INSTALL N W WINDOW THAT Ig EGRESg CQMPLIANT,
<br />- CHECK WITH PERMIT AUTHORITY REGARDING THE LARGE VARIATION IN RISER
<br />HEIGHT OF THE EXISTING STAIRS. RECOMMEND REMOVING THE STAIRS
<br />ENTIRELY AND REBUILDING THEM CORRECTLY
<br />(�2
<br />- REMOVE PANTRY FLOOR SYSTEM ABOVE LANDING TO REMOVE HEADROOM
<br />CLEARANCE ISSUE.
<br />- BUILD ELEVATED PANTRY FLOOR/SHELF AT APPROPRIATE HEIGHT TO PASS
<br />DE '- " LAIN HEADROOM LEARAN E.
<br />®ENGINEERING
<br />TO SPECIFY POINT LOAD PATH FROM GROUND/FOUNDATION UP
<br />TO BEAM SUPPORT FRAMING ABOVE MIN FLOOR
<br />4
<br />INSTALL SMOKE DETECTORS IN EACH BEDROOM
<br />Replace HDU2 w/ strap Replace HDU2 w/ strap
<br />hold down per sheet S 1, hold down per sheet S 1, THIS WAS EXTERIOR
<br />detail D2 detail D 1 WALL PRIOR TO
<br />GARAGE ADDITION.
<br />HOU . 5P5 PLEASE CHECK
<br />STRUCTURAL DESIGN
<br />EX) c5T, LR 5T 15 ADMU4TE
<br />1 1
<br />::. .r......: _ __._._......, .0._.._
<br />t�_....... ._...I�src�c�s�T _, � �� PROVIDE FLOOR
<br />NEW �,•'
<br />S WER : ° FRAMING FOR MASTER
<br />BEDROOM EXPANSION
<br />F 19'-5 5'-01/2" 21'-4 1 t2,. ,
<br />_._.._._..__..._.._......._ _..... (THIS AREA WAS PART
<br />MASTER
<br />BATH _ OF THE GARAGE)
<br />..
<br />4? W 61SoFt
<br />_ WNN
<br />MASTERCc �
<br />W 00 LIVING
<br />d Z v 19'-4"X 14'-7.. BEDROOM
<br />o r21=a" x 12`
<br />a
<br />r T.
<br />CD
<br />1
<br />00 --..
<br />-, .
<br />i F=- {
<br />13'-6 ... _:... i.^5 _... s . ,3 WINDOWS TO BE INFILL
<br />RIA �� f`
<br />HALL _ .._..
<br />iV
<br />9 c 4'-5"X 14'-6" _ BATH
<br />..- ,
<br />... ` iw sr, FT T-f> ` X 6'-.7"n' 4
<br />IS THIS NEW WORK?
<br />15'-101/2" 2'-10" 11'-4 1/2" 12'-71/2"
<br />PLEASE ONFIR .
<br />i . �.. YES , C. F I ELD v.ERe FYI
<br />-- GARAGE
<br />12'-7" X 18'-I"
<br />JLL
<br />DWw- CLOSET +, 1
<br />11
<br />HALL `V
<br />i N
<br />10 5
<br />j �,�,
<br />SHOW EXISTING WINDOW 7
<br />KITCHEN ._...-. I I BEDROOM #2 TO BE REPLACE
<br />11'-5" X 16' }- (( 1V-4" X 11`-8•' 3 I
<br />PAN Y v I
<br />MIT
<br />IN
<br />I I
<br />SHOW DOOR TO SWING
<br />OUT
<br />NEW STAIR PROVIDE
<br />NECESSARY FRAMING
<br />MAIL ZX I -'LAF * Z 5TKI.16E:R TProvide strap hold down
<br />5TU.D W/ ( S) I G J 0. I to`I V/L C T-Yr per sheet S 1, detail D3
<br />.WZ.Tr7C A,-DS T'D
<br />SCALE: 1 /4 V-0"
<br />WINDOWS TO BE INFILL
<br />NAIL 2-A 12 �P IS THIS NEW WORK?
<br />5 Rll� � M / L3�) I W EA END
<br />Ci`IP� PLEASE CONFIRM.
<br />yE5, C R EID V ERI FY
<br />-3036LS,- - - - - - --r.3036LS. - 3030LS. �
<br />.. 3068
<br />_ __ .....,-
<br />.�
<br />T-3"
<br />8'-01/2"
<br />16'-811
<br />N
<br />BEDROOM#3
<br />HALL
<br />LAUNDRY
<br />16-5 X16-1t,
<br />FT
<br />9,-7 X26-2"
<br />8 X12
<br />i224
<br />SQ
<br />193 SQ FT
<br />0 4$ $Q FT
<br />I I
<br />I
<br />I I off'ED
<br />_FOOTING ?
<br />I S 18" WIDE k I S 11 LDS V 81 ?m� k iT
<br />I,�.IW ('Z)
<br />-44 W 1.'y! 4 A W C.Ur SC.A S AG 9 '1� C SET 3 /�
<br />I�.: 9" X 5'-9" F01 NIT L AD • FOWT UAD
<br />t1 ,, I AFT ABfl�tE • A I.
<br />24 , 24W Iff x 24 LONG I TI�a k i UNEXCAVATED
<br />_ _ -` I 12'-3" X 30'-,3"
<br />(Z)* A- EA UL&Y :x �"37180 FT
<br />BRICK FIREPLACE
<br />L
<br />266s00
<br />Q MECH Q
<br />'f
<br />I�
<br />I v
<br />SQ FT N
<br />I I I
<br />N
<br />1
<br />i BATH
<br />I I I
<br />I
<br />r• 8' X 15'-9"
<br />I_
<br />.....
<br />124 SQ FT•
<br />NEW WINDOW
<br />OPENING
<br />12'-111/2"
<br />2'-101 4"
<br />5'-0 3/4" 8'-01/2"
<br />BEDROOM #4 �,
<br />a
<br />o
<br />II
<br />I 12'-11" X 1IT-10" p
<br />1$��QFr r
<br />LU
<br />I I o�
<br />I I' I
<br />2
<br />6068
<br />CLOSET -BATH
<br />-
<br />13 SO FT
<br />1) ALL DIMENSIONS ARE FROM FACE OF STUD TO FACE OF STUD.
<br />- -�' - - wl.l--
<br />.Y�w -.�-- _ arAt M. .M-IIr .ram.. .rrl�
<br />_.. J
<br />�M. ..,p :.: "'{': •-:, 1 .. . t...:: '.. ., .: ..r Ar.: ,y' ra., a<,.'.•.�.nM1�:.rf,. ...,,':.. .: , . '� ..;. : .,•:. .. ., .
<br />2)ALL BEDROOM WINDOWS SHALL MEET CODE REQUIRING
<br />NEW FURRED
<br />t----------------_------------1
<br />EGRESS.
<br />WALL
<br />(1) OOBECTIVEPLANS - BASEMENT
<br />r�r.�r.�-r rrr�rr-.rr_nrn mrr-i-urr
<br />NEW STAIR PROVIDE SCALE:1/4" =1'-0"
<br />NECESSARY FRAMING
<br />0 5A IM E AS A BVVID
<br />IF EVERETT
<br />CITY Oar r-
<br />REEVIEWED FOR PERM;
<br />MT.1 5 202
<br />JUN 0 6 JW-
<br />ACCURA11' SCALLS WIZEN PRINTIA)
<br />At lnniv- 111.1 IA Y 7'..AM,t!f nt DALE 11
<br />JECT NUMBER
<br />-162-04
<br />W11,1(, INDI•X
<br />F
<br />NAMI
<br />1MAt.11
<br />DATE DRAWN: 2021-SEP-17
<br />DRAWN BY: MA
<br />REVISION HISTORY
<br />revA: 2021-09-29 MA2
<br />revS: •.
<br />revC:
<br />revD:
<br />revE:
<br />revF:
<br />BUILDER
<br />AURORA BUILT, LLC
<br />-DANIEL NAVAS-
<br />PHONE: (425) 595-8317
<br />EMAIL: Info@aurorabuiit.com
<br />UBI: 604 728 404
<br />LIC: AUtt 9009JS
<br />PERMIT AUTHORITY
<br />SNOHOMISH
<br />PERMIT OFFICE
<br />PERMIT CENTER
<br />3000 Rockefeller ►venue
<br />Everett, WA 98201
<br />Phone: (425) 388-3433
<br />U)
<br />1
<br />Z
<br />o
<br />.�
<br />Q
<br />�
<br />O
<br />CL
<br />o 1
<br />L11
<br />a 1
<br />>
<br />c�
<br />1--
<br />�
<br />U
<br />m
<br />W
<br />o
<br />Qlo-
<br />o
<br />,
<br />', , LL
<br />O
<br />� 1
<br />CU
<br />M •
<br />> 1
<br />O �
<br />N Cr to
<br />00W�'-.
<br />OM% le tV
<br />Z
<br />Z
<br />ZW N
<br />0
<br />W Ce o
<br />X wZ©
<br />QN�
<br />(3)
<br />®
<br />00 qr-
<br />Cr> u J 0
<br />z DfjN
<br />z
<br />Uco
<br />2 l." z o 1
<br />W
<br />= nN©
<br />00 1
<br />00 a
<br />NZC~7crm
<br />°L
<br />�Cw�Oo,
<br />0
<br />�
<br />cc a LL
<br />X Coco*
<br />a(0)No
<br />t� a IW --
<br />LLJ�Z
<br />t
<br />W J S W
<br />(D 0 c
<br />z
<br />ui
<br />l000
<br />tl3 U)) ."'.1 N a
<br />�
<br />t
<br />t
<br />2
<br />:W E `
<br />Z O
<br />C
<br />0 .,..
<br />C
<br />oft
<br />/�
<br />/ ) �..� l
<br />> 00 M
<br />< 0.;
<br />G
<br />e
<br />www.1 CO
<br />F
<br />LJJ t.
<br />� L
<br />Z �.{}
<br />C14 4-
<br />SHEET
<br />TITLE c
<br />CORRECTIVES
<br />SHEET DISCIPLINE s
<br />u
<br />c
<br />c
<br />2
<br />u
<br />4
<br />ANSI D
<br />AV V V.{I1i i !f L PVf14G.7 r.nrn rrtm, c�
<br />AT 100% ON 11 X 171ANSI B) PAPER
<br />
|