My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2420 38TH ST ROYELL MANUFACTURING 2025-03-27
>
Address Records
>
38TH ST
>
2420
>
ROYELL MANUFACTURING
>
2420 38TH ST ROYELL MANUFACTURING 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 12:02:05 PM
Creation date
10/12/2023 7:00:41 AM
Metadata
Fields
Template:
Address Document
Street Name
38TH ST
Street Number
2420
Tenant Name
ROYELL MANUFACTURING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALLATION--CONTINUED <br /> Piping Connections—Continued <br /> Gas Supply Piping—Continued <br /> Table 14. Gas Supply Line Sizes <br /> Diameter of Pipe inches <br /> Length 1/2 314 1 1 1-1/4 1-1/2 2 <br /> of Pipe Natural Natural Natural Natural Natural Natural <br /> Propane Propane Propane Propane Propane Propane <br /> (Feet) Gas Gas Gas Gas , Gas` Gas <br /> Cubic Feet per Hour` <br /> 20 92 56 190 116 350 214 730 445 1100 671 2100 1281 <br /> 30 73 45 152 93 285 174 590 360 890 543 1650 1007 <br /> 40 63 38 130 79 245 149 500 305 760 464 1450 885 <br /> 50 56 34 115 70 215 131 440 268 670 409 1270 775 <br /> 60 50 31 105 64 195 119 400 244 610 372 1105 674 <br /> 70 46 28 96 59 180 110 370 1 226 560 342 1 1050 641 <br /> 80 43 26 90 55 170 104 350 214 530 323 990 604 <br /> 90 40 24 84 51 160 98 320 195 490 299 930 567 <br /> 100 38 23 79 48 150 92 305 186 460 281 870 531 <br /> 125 34 21 72 44 130 79 275 168 1 410 250 780 476 <br /> 150 31 19 64 39 120 73 250 153 380 232 710 433 <br /> 175 28 17 59 36 110 67 1 225 137 350 1 214 1 650 397 <br /> 200 26 16 55 34 100 61 210 128 1 320 1 195 1 610 372 <br /> Supply Piping Connections <br /> • Install a ground joint union and manual shutoff valve upstream of the unit control system, as shown in Figure 9. <br /> • The 1/8-inch plugged tapping in the manual shutoff valve in Figure 9 provides connection for a supply line pressure <br /> test gauge. <br /> • The National Fuel Gas Code requires the installation of a trap with a minimum 3-inch drip leg(see Figure 9).Local <br /> codes may require a drip leg longer than 3 inches(typically 6 inches).To permit burner removal,this drip leg must <br /> extend beyond the edge of the heater. <br /> • Leak-test all connections by brushing on a leak-detecting solution. Bleed trapped air from gas lines as needed. <br /> • The gas connection is made at the pipe nipple that extends outside the cabinet, as shown in Figure 9. Gas <br /> connection sizes are listed in Table 15. <br /> Ground Joint Union <br /> To Gas Valve. F-Manual shutoff <br /> (inside the <br /> cabinet) <br /> Drip f From Gas Supply <br /> Leg (horizontal or vertical) <br /> i <br /> Pipe nipple extending <br /> outside the cabinet <br /> �–Manual shutoff <br /> To Gas Valve <br /> (inside the 'q- <br /> cabinet) f <br /> Ground Drip <br /> Joint Leg <br /> Union <br /> Figure 9. Gas Connections <br /> 20 i-UBX-UBZ-UDX-UDZ(04-21)1034344-0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.