Laserfiche WebLink
Table 15. Gas Connection Sizes <br /> Unit Size Natural Gas Propane <br /> Connection(inches)* <br /> 030-200 1/2 112 <br /> 225-400 3/4 3/4 <br /> *Connection size for a standard unit not gas supply line size). <br /> Electrical Connections <br /> 0 CAUTION ,& <br /> • Route wires so that they do not contact the flue wrapper or venter housing. <br /> • If any of the original wire supplied with the appliance must be replaced, it must be replaced with <br /> wiring material having a temperature rating of at least 105°C,except for limit control,flame rollout, <br /> and sensor lead wires which must be rated at 150°C. <br /> NOTES: <br /> • Specific wiring diagrams that include standard and factory-installed options are provided with <br /> the unit. Ensure that all wiring is in accordance with these wiring diagrams. <br /> • A two-stage valve circuit is NOT available on all models. <br /> • All electrical wiring and connections,including electrical grounding MUST be made in accordance with the National <br /> Electric Code ANSI/NFPA No.70(latest edition)or, in Canada,with CSA Standard C22.1. In addition,the installer <br /> should be aware of any local ordinances or gas company requirements that might apply. <br /> • Check the rating plate on the heater for the supply voltage and current requirements. A dedicated line voltage <br /> supply with a disconnect switch should be run directly from the main electrical panel to the heater. <br /> • All external wiring must be within approved conduit and have a minimum temperature rise rating of 60°C. Conduit <br /> must be run so as not to interfere with the heater access panel. <br /> • If the Installation requires a stepdown transformer (option CG on some models), follow the instructions shipped <br /> with the option package for installing the transformer. <br /> • The supply wiring enters at the rear of the heater, as shown in Figure 10. For UBX and UDX models, the supply <br /> wiring connects directly to leads on the integrated circuit board. For UBZ and UDZ models, the supply wiring <br /> connects to leads located inside a sealed electrical box. To maintain the sealing feature of the electrical box, <br /> always replace the cover plate. <br /> • The terminal strip for 24V control connections is located on the outside of the cabinet at the back of the heater, as <br /> shown in Figure 10.Wires from the terminal strip are factory-wired to the circuit board. <br /> • UDZ and UBZ units have a built-in disconnect switch (20A@115V or 10A@230V rating), as shown in Figure 10. <br /> i-UBX•UBZ•UDX-UDZ(04-21)1034344-0 21 <br />