STANDARD LABELS <br />ft�!WARNING4 <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />RATED AC OUTPUT CURRENT 9.68 A <br />NOMINAL OPERATING AC VOLTAGE 240 V <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />OWARNINOV <br />POWER SOURCE OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />DEVICE <br />OWA%VG <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES, EXCLUDING <br />MAIN SUPPLY OVERCURRENT <br />DEVICE, SHALL NOT EXCEED <br />AMPACITY OF BUSBAR. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />..OFF. POSITION TO sown e�ecTaic <br />SHUT DOWN PV SYSTEM av Pade�s <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />LABELING NOTES <br />LABEL 1 <br />FOR PV SYSTEM DISCONNECTING MEANS WHERE THE <br />LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE <br />OPEN POSITION. <br />[2017 NEC 690.13(8)] <br />[2020 NEC 690.13(8)] <br />LABEL 2 <br />SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT <br />THE DISCONNECTING MEANS AS A POWER SOURCE <br />AND WITH THE RATED AC OUTPUT CURRENT AND THE <br />NOMINAL OPERATING AC VOLTAGE. <br />(2017 NEC 690.541 <br />(2020 NEC 690.541 <br />LABEL 3 <br />IF INTERCONNECTING LOAD SIDE, INSTALL THIS LABEL <br />ANYWHERE THAT IS POWERED BY BOTH THE UTILITY <br />AND THE SOLAR PV SYSTEM, IE. MAIN SERVICE PANEL <br />AND SUBPANELS. <br />(2017 NEC 705.12(8)(3)] <br />(2020 NEC 705.12(8)(3)] <br />LABEL 4 <br />APPLY TO THE DISTRIBUTION EQUIPMENT ADJACENT <br />TO THE BACK -FED BREAKER FROM THE POWER <br />SOURCE. <br />[2017 NEC 705.12(8)(2)(3)(b)] <br />(2020 NEC 705.12(8)(3)(2)] <br />LABEL 5 <br />APPLY TO THE PV COMBINER BOX <br />(2017 NEC 705.12(8)(2)(3)(c)] <br />(2020 NEC 705.12(8)(3)(3)] <br />W�WARNINGJ <br />MAIN DISTRIBUTION UTILITY DISCONNECT(S) <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM A ROOF MOUNTED SOLAR ARRAY WITH <br />A RAPID SHUTDOWN DISCONNECTING MEANS <br />GROUPED AND LABELED WITHIN LINE OF SITE <br />AND 10 FT OF THIS LOCATION <br />WARNING <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM MAIN DISTRIBUTION <br />UTILITY DISCONNECT LOCATED <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM A ROOF MOUNTED SOLAR ARRAY. SOLAR <br />ARRAY RAPID SHUTDOWN DISCONNECT IS <br />LOCATED OUTSIDE NEXT TO THE UTILITY METER. <br />PHOTOVOLTAIC SYSTEM <br />COMBINER PANEL <br />DO NOT ADD LOADS <br />UTILITY <br />MAIN <br />METER <br />SERVICE PANEL <br />O O <br />LABEL 6 <br />BUILDINGS WITH PV SYSTEMS SHALL HAVE A <br />PERMANENT LABEL LOCATED AT EACH SERVICE <br />2 3 <br />EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS <br />ARE CONNECTED OR AT AN APPROVED READILY <br />VISIBLE LOCATION AND SHALL INDICATE THE LOCATION <br />OF RAPID SHUTDOWN INITIATION DEVICES. <br />0 <br />O IF BREAKER <br />IS USED <br />(2017 NEC 690.56(C)(1)(a)] <br />(2020 NEC 690.56(C)] <br />O OR 10 <br />OR PLACARD <br />LABEL 7 <br />SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT <br />SWITCH <br />[2017 NEC 690.56(C)(3)] <br />[2020 NEC 690.56(C)(2)] <br />1) LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT <br />REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. <br />2) LABELING REQUIREMENTS BASED ON THE 2017 & 2020 NEC CODE, OSHA STANDARD 19010.145, ANSIZ535. <br />3) MATERIAL BASED ON THE REQUIREMENTS OF THE AHJ. <br />4) LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL NOT BE <br />HANDWRITTEN [NEC 110.21] <br />ADDITIONAL LABELS <br />BLUE RAVEN <br />LABEL 8 <br />PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br />LOCATION OF ALL ELECTRIC POWER SOURCE <br />1403 N. Research Way <br />DISCONNECTING MEANS ON OR IN THE PREMISES <br />SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT <br />Orem, UT 84097 <br />LOCATION AND AT THE LOCATION(S) OF THE SYSTEM <br />800.377.4480 <br />DISCONNECT(S) FOR ALL ELECTRIC POWER <br />WWW.BLUERAVENSOLAR.COM <br />PRODUCTION SOURCES CAPABLE OF BEING <br />CONFIDENTIAL -THE INFORMATION <br />INTERCONNECTED. <br />[2017 NEC 705.10] <br />HEREIN CONTAINED SHALL NOT BE <br />[2020 NEC 705.10] <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />LABEL 9 <br />IN PART TO OTHERS OUTSIDE <br />PERMANENT PLAQUE OR DIRECTORY DENOTING THE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />LOCATION OF ALL ELECTRIC POWER SOURCE <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />DISCONNECTING MEANS ON OR IN THE PREMISES <br />WITHOUT THE WRITTEN PERMISSION <br />SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT <br />OF BLUE RAVEN SOLAR LLC. <br />LOCATION AND AT THE LOCATION(S) OF THE SYSTEM <br />DISCONNECT(S) FOR ALL ELECTRIC POWER <br />PRODUCTION SOURCES CAPABLE OF BEING <br />/� <br />NABC E P <br />INTERCONNECTED. <br />[2017 NEC 705.101 <br />[2020 NEC 705.10] <br />CERTIFIED <br />PV INSTALLATION <br />LABEL 10 <br />PROFESSIONAL <br />PERMANENT PLAQUE OR DIRECTORY TO BE <br />LOCATED AT MAIN SERVICE EQUIPMENT DENOTING <br />Scott Gurney <br />THE LOCATION OF THE RAPID SHUTDOWN SYSTEM <br />#PV-011719-015866 <br />DISCONNECTING MEANS IF SOLAR ARRAY RAPID <br />SHUTDOWN DISCONNECTING SWITCH IS NOT <br />CONTRACTOR: <br />GROUPED AND WITHIN LINE OF SITE OF MAIN <br />BRS FIELD OPS <br />SERVICE DISCONNECTING MEANS. <br />800-377-4480 <br />(2017 NEC 705.10 AND 690.56(C)(1)(a)] <br />[2020 NEC 705.10 AND 690.56(C)] <br />LABEL 11 <br />PERMANENT PLAQUE OR DIRECTORY TO BE <br />LOCATED AT AC COMBINER PANEL. <br />U <br />Q <br />[2017 NEC 110.21(8)] <br />[2020 NEC 110.21(8)] <br />Z <br />_0 <br />O <br />Q <br />H <br />04 <br />2 00 <br />N <br />M N <br />O) <br />04 M <br />SUBPANEL <br />(IF INTERCONNECTION <br />AC PV <br />PV COMBINER <br />O O <br />LL <br />a) <br />Z N > <br />W W <br />N N <br />0 (j) <br />IS MADE HERE) <br />DISCONNECT METER <br />BOX <br />w M <br />W -0 <br />0 <br />0 <br />°a <br />2 3 <br />O O <br />7 <br />O <br />5 <br />O <br />8 <br />O <br />=_0 o> <br />/v>_>_ <br />/ V/ <br />0Lu[--Lu <br />ao <br />O O <br />OOR PLACARD <br />11 <br />DRAWING BY: <br />:�iaii•"FT WIrl%% <br />PLOT DATE: <br />June 9, 2023 <br />PROJECT NUMBER: <br />750417 <br />SHEET NAME: <br />*ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL LABELS <br />REPRESENTATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PRESENTED REVISION: PAGE NUMBER: <br />MAY VARY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON 3 LINE 0 PV7 <br />DIAGRAM. 3 LINE DIAGRAM ON PV5 TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. <br />
The URL can be used to link to this page
Your browser does not support the video tag.