My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7730 GRANT DR 2023-10-25
>
Address Records
>
GRANT DR
>
7730
>
7730 GRANT DR 2023-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 8:54:17 AM
Creation date
10/18/2023 9:30:17 AM
Metadata
Fields
Template:
Address Document
Street Name
GRANT DR
Street Number
7730
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
onn S-FM-RAFME UL CODE COMPLIANCE NOTES:20 <br />M M -- MICRORAIL'" ----------------------------------------------------------- INSTALLATION GUIDE-'I- PAGE <br />SYSTEM LEVEL FIRE CLASSIFICATION <br />The system fire class rating requires installation in the manner specified in the <br />SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to <br />the system level fire portion of UL 1703. This UL 1703 classification has been <br />incorporated into the UL 2703 product certification. SFM has achieved Class A, <br />B & C system level performance for low slope & steep sloped roofs when used <br />in conjunction with type 1 and type 2 modules. Class A, B & C system level fire <br />performance is inherent in the SFM design, and no additional mitigation measures <br />are required. The fire classification rating is valid for any roof pitch. There is no <br />required minimum or maximum height limitation above the roof deck to maintain <br />the Class A, B & C fire rating for SFM. SUNFRAME M ICRORAI L11 components shall <br />be mounted over a fire resistant roof covering rated for the application. <br />Module Type <br />Roof Slope <br />System Level Fire Rating <br />Microrail Direction <br />Module Orientation <br />Mitigation Required <br />Type 1 and Type 2 <br />Steep Slope & Low Slope <br />Class A, B & C <br />East-West <br />Landscape OR Portrait <br />None Required <br />U1.2 7 0 3 TEST MODULES <br />See pages 22 and 23 for a list of modules that were electrically and mechanically tested or <br />qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. <br />• Maximum Area of Module = 27.76 sqft <br />• UL2703 Design Load Ratings: <br />a) Downward Pressure - 113 PSF / 5400 Pa <br />b) Upward Pressure - 50 PSF / 2400 Pa <br />c) Down -Slope Load - 21.6 PSF / 1034 Pa <br />• Tested Loads: <br />a) Downward Pressure - 170 PSF / 8000 Pa <br />b) Upward Pressure - 75 PSF / 3500 Pa <br />c) Down -Slope Load - 32.4 PSF / 1550 Pa <br />• Maximum Span = 6ft <br />• Use with a maximum over current protection device OCPD of 30A <br />• System conforms to UL Std 2703, certified to LTR AE-001-2012 <br />• Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span <br />• PV modules may have a reduced load rating, independent of the SFM load rating. Please consult <br />the PV module manufacturer's installation guide for more information <br />• Down -Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less <br />BLUE RAVEN <br />1403 N. Research Way <br />Orem, UT 84097 <br />800.377.4480 <br />W W W.BLUERAVENSOLAR.COM <br />CONFIDENTIAL- THE INFORMATION <br />HEREIN CONTAINED SHALL NOT BE <br />USED FOR THE BENEFIT OF ANYONE <br />EXCEPT BLUE RAVEN SOLAR NOR <br />SHALL IT BE DISCLOSED IN WHOLE OR <br />IN PART TO OTHERS OUTSIDE <br />RECIPIENTS ORGANIZATION, EXCEPT <br />IN CONNECTION WITH THE SALE AND <br />USE OF THE RESPECTIVE EQUIPMENT, <br />WITHOUT THE WRITTEN PERMISSION <br />OF BLUE RAVEN SOLAR LLC. <br />NABCEP <br />CERTIFIED <br />PV INSTALLATION <br />PROFESSIONAL <br />Scott Gurney <br />4PV-011719-015866 <br />CONTRACTOR: <br />BRS FIELD OPS <br />385-498-6700 <br />DRAWING BY: <br />PLOT DATE: <br />PROJECT NUMBER: <br />SHEET NAME: <br />SPEC SHEET <br />REVISION: <br />PAGE NUMBER: <br />SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.