_r� <br />In <br />Model CC-2 Model CC-5 <br />CC-5 / CC-2 —), Card Cages <br />The Model CC-5 I CC-2 card cages <br />provide the physical mounting <br />location and all wiring connection <br />points for all fire -and -voice system <br />options cards to each Cerberus PRO <br />Modular system. Model CC-5 has five <br />(5) slots, while Model CC-2 has two <br />(2) slots. <br />All cards plugged into each CC-5 I CC-2 <br />card cage communicate with other <br />Cerberus PRO Modular system <br />modules via a common data bus. <br />Connectors are provided on the left <br />and right side of the CC-5 to connect <br />a 60-pin cable for communications <br />with the Cerberus PRO Modular <br />operator interface, power supplies <br />and amplifiers modules. <br />Field wiring to devices and circuits <br />terminates on the Models CC-5 I CC-2 <br />card cages. All cards designed for use <br />with the Models CC-5 I CC-2 route <br />their field wiring terminations to the <br />'top' of the Model CC-5 I CC-2 card <br />cages. These connections are all <br />power limited. Internal wiring <br />connections distribute 24VDC to cards <br />or high-level audio signals <br />(depending on application used) <br />connect to the 'bottom' of the Model <br />CC-5 I CC-2 card cages. These <br />connections are all non -power <br />limited. <br />All wiring connections to the Model <br />CC-5 I CC-2 card cages are to <br />removable terminal blocks. Terminal <br />blocks are rated for use with wire <br />sized 12 American Wire Gauge (AWG) <br />to 24AWG. Each connector is <br />numbered to make wiring <br />terminations to the correct position <br />on the terminal <br />block simple in order to reduce <br />potential system -wiring errors. <br />In <br />SCM-8 —> Switch Control Module <br />The Switch Control Module (Model SCM- <br />8) is a Cerberus PRO Modular system <br />option module that provides manual <br />control of the Emergency Voice <br />Evacuation System or manual fire system <br />control. Each Model SCM-8 module has <br />eight (8) momentary push-button <br />switches and 16 LEDs to indicate their <br />status. Each switch is assigned two (2) <br />LEDs and a label to indicate the Model <br />SCM-8 switch is in use. <br />The label slides behind a clear, protective <br />covering, and one of the LEDs assigned to <br />each switch is a dual -color LED used to <br />indicate what type of signal is active. Each <br />Model SCM-8 and switch is fully <br />programmable, and may be used to <br />control speaker circuits and a wide range <br />of general -system functions such as: <br />'All Call' I 'All Evac' j 'Speaker' l etc. <br />Any number of circuits may be grouped <br />and controlled by a single switch. Switch <br />usage and zone groupings are assigned <br />using the Cerberus PRO Modular system - <br />programming tool, Zeus-C. <br />Model SCM-8 is mounted on a hinged <br />panel, as part of the Cerberus PRO <br />Modular Command Console (C.C.) <br />enclosure. <br />LCM-8 —> LED Control Module <br />The LED Control Module (Model LCM-8) <br />is a Cerberus PRO Modular system option <br />module that provides LED annunciation <br />for system activity. Each Model LCM-8 <br />module contains eight (8) groups of two <br />(2) LEDs — each of which can be assigned <br />to desired outputs, via the Modular <br />system -programming tool, Zeus-C. <br />Eight (8) LEDs are dual -color capable of <br />emitting either in RED or GREEN - <br />'Flashing' or 'Steady. The remaining <br />LEDs are AMBER — 'Flashing' or 'Steady'. <br />There is a space provided for labeling of <br />LED functions. The label slides behind a <br />clear, protective membrane. <br />Model LCM-8 dimensions are identical to <br />Model SCM-8, and the LED control <br />module is mounted on the same hinged <br />panel, as part of the Cerberus PRO <br />Modular C.C. enclosure. <br />FCM-6 --> Fan Control Module <br />The Fan I Motor I Dampers Control <br />Module (Model FCM-6) is a Cerberus PRO <br />Modular system command -console <br />option module that provides manual <br />control of the fans, motors, and dampers <br />used in building heating I ventilation <br />air-conditioning (HVAC) systems. <br />Each Model FCM-6 module provides six <br />(6) sets of three (3) push-button <br />switches for manual -system control. <br />Each switch has three (3), associated <br />LEDs to indicate Fan I Damper I Motor <br />status: OFF (RED LED); ON (GREEN LED), <br />-Trouble' (YELLOW LED). When manually <br />switched to the ON position, the GREEN <br />LED will flash, indicating the output <br />circuit used to turn on the Fan I Damper <br />has activated. The GREEN LED will light to <br />a steady green to indicate positive <br />feedback of the Fan I Damper actually <br />turning on (via a monitored input.) <br />If% <br />IIC —> Interface Isolation Card <br />The Interface Isolation Card (Model IIC) <br />is designed to isolate network signals <br />when used with a Cerberus PRO Modular <br />Command Console (C.C.) ring <br />configuration, via the network -ring card, <br />Model NRC. Model IIC executes the <br />aforementioned isolation by removing <br />the backplane network signals from <br />each Model CC-2 card cage. Model IIC <br />also provides one (1) end of CAN <br />termination on each side of Model CC-2. <br />Two (2) 60-pin interfaces are <br />contained in each Model IIC: the <br />male -ribbon -cable receptacle accepts <br />the data from the cable of the <br />previous Model CC-2 card cage, and <br />the female -ribbon -cable receptacle <br />plugs into the 60-pin receptacle of the <br />next -in -line Model CC-2 card cage. <br />Siemens <br />Building Technologies Division -5- usa.siemens.comlcerberus-pro-modular <br />