3003 W CASINO RD BASE FILE 2023-10-24
>
Address Records
>
W CASINO RD
>
3003
>
BASE FILE
>
3003 W CASINO RD BASE FILE 2023-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2023 2:19:14 PM
Creation date
10/20/2023 6:22:48 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
250
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CAB -MP —> Cabinet Mounting Plate <br />The cabinet -mounting plate for Cerberus <br />PRO Modular systems, Model CAB -MP, <br />provides mounting for a single row of <br />system modules housed in a Cerberus <br />PRO Modular system enclosure. Up to <br />four (4) module spaces are available on one <br />(1) Model CAB -MP plate. <br />Each of these mounting plates is used to <br />mount the Model CC-5 Card Cage; the <br />Model CC-2 Card Cage; the Model PSC-12 <br />power supply, and the Model PSX-12 <br />power -supply extender for Cerberus PRO <br />Modular fire -only systems. <br />ID -MP —>Inner Door Mounting Plate <br />The inner -door mounting plate (Model <br />ID -MP) is mounted on the inner door of <br />any given Model CAB -series enclosure. <br />Each Model ID -MP plate is used to <br />mount switch -control modules (Model <br />SCM-8); LED control modules (Model <br />LCM-8), or fan -control modules (FCM-6). <br />Four (4) mounting plates are included <br />with one (1) order of Model ID -MP. <br />Each mounting plate has four (4) <br />spaces for control modules, and can <br />hold either four (4) Model SCM-8 <br />modules: one (1) control -module <br />space for each actual module, or two <br />(2) fan -control modules: two (2) <br />module spaces per each Model FCM-6. <br />Mounting combinations are possible. <br />Blank spaces found in Model ID -MP <br />plates can be covered using the blank - <br />control module plate (Model BCM). Up <br />to four (4) modules can be mounted on <br />a single row of the inner door. <br />Blank Control <br />Module Plate <br />BCM —> Blank Control Module Plate <br />Blank Control Module Plates (Model <br />BCM) can be mounted on a single ID -MP. <br />Four (4) blank module plates are <br />included with each order of Model BCM. <br />ID-SP —> Inner Door, <br />Single (blank) Plate <br />The inner door, single blank plate (Model <br />ID-SP) is used to cover any single -module <br />blank spaces within the inner door where <br />no Cerberus PRO Modular Operator <br />Interface or Model ID -MP is being used. <br />Up to four (4) Model ID-SP modules can <br />be mounted in a single row on the inner <br />door. Two (2) blank plates are included <br />with each order of Model ID-SP. <br />OD -LP —> Outer <br />Door Lens Plate <br />The outer -door lens <br />plate (Model OD -LP) <br />is a clear, plastic lens Outer <br />plate mounted on Door Lens Plate <br />the outer door of a system cabinet. <br />Model OD -LP is used to allow operators <br />to see the system interface and <br />controls mounted on the inner door, but <br />restricts access to unauthorized users. <br />The plate covers an entire row on the <br />outer door. <br />One (1) single lens plate is included <br />with each order of Model OD -LP. <br />OD -GP —> Outer Door Grill Plate <br />The outer -door grill plate (Model OD -GP) <br />covers an entire row on the outer door of a <br />system cabinet, but has four (4) rows of <br />ventilation louvers on it. Model OD -GP is <br />mounted in front of system bulk <br />amplifiers, card amplifiers, or other <br />modules that generate heat. Using Model <br />OD -GP will permit airflow across these <br />modules to aid in heat dissipation. <br />One (1) grill plate is included with <br />each order of Model OG-GP. <br />OD -BP —> Outer Door <br />Blank Plate <br />The outer -door blank plate (Model OD - <br />BP), which mounts on the outer door of <br />a Cerberus PRO Modular enclosure, <br />entirely covers an unused row found on <br />a Cerberus PRO Modular system cabinet. <br />Outer Inner <br />Door Door <br />Adapter <br />Plate <br />XLS-MSE2/R-ADPT —>Enclosure <br />Adapter <br />Model XLS-MSE2-ADPT, which must be <br />used in conjunction with Model CAB -MP <br />plates, is an adapter that allows <br />Cerberus PRO Modular cards to be <br />mounted in older -generation MXL <br />Model MSE-2—series small black <br />enclosures. <br />Model XLS-MSE2R-ADPT, which must <br />be used in conjunction with Model CAB - <br />MP plates, is an adapter that allows <br />Cerberus PRO Modular cards to be <br />mounted in older -generation MXL <br />Model MSE-2R small red enclosures. <br />AW <br />Adapter <br />Plate <br />XLS-MME3/R-ADPT —>Enclosure <br />Adapter <br />Model XLS-MME3-ADPT, which must be <br />used in conjunction with Model CAB -MP <br />plates, is an adapter that allows <br />Cerberus PRO Modular cards to be <br />mounted in older -generation MXL <br />Model MME-3—series or Model MBR-2 <br />medium black enclosures. <br />Model XLS-MME3R-ADPT, which must <br />be used in conjunction with Model CAB - <br />MP plates, is an adapter that allows <br />Cerberus PRO Modular cards to be <br />mounted in older -generation MXL <br />Model MME-3R medium red <br />enclosures. <br />Siemens <br />Building Technologies Division —7— usa.siemens.comlcerberus-pro-modular <br />