Laserfiche WebLink
Janet R. Soriano <br />Plan Check Number: 82108-011, First Building Review <br />October 26, 2021 <br />4. See Sheet 1 and 2. Plans should show how second story walls are supported. Specifically, the <br />corner walls above the start of the stairway. Plans should provide a detail/information of how <br />the scissor trusses in the Living Room extension are connected at the wall/beam above the stair <br />location. <br />15. See Sheet 1 and 2. Provide framing support/foundation for the stairs and stair landings. <br />R106.1.1 <br />Additional Comments <br />1. A beam calculation was submitted for the 8 3/4 x 15 GLB. Plans should specify the <br />species/grade of the GLB, the bearing support requirements, and connections of existing <br />framing members to the new beam. Calculations should be submitted confirming the existing <br />footing is adequate for the reaction of the beam. <br />This review has been performed for general compliance with the building codes as adopted and <br />amended by the state of Washington and the city of Everett. Corrections and comments made <br />during the review process do not relieve the project from compliance with code and permit <br />requirements. The designers -of -record are responsible for a complete design in accordance with <br />the laws of the state of Washington. <br />If you have any questions or require additional clarification, please contact us. <br />Respectfully, <br />Rakeeb Khan <br />Residential Plans Examiner <br />(425)257-7299 <br />rkhan@everettwa.gov <br />S:\RKhan\2021\B2108-011_R2.docx <br />3200 Cedar Street <br />Everett, DNA 98201 <br />425.257.8810 <br />425.257.8857 fax <br />everetteps@everettwa.gov <br />everettwa.gov/permits <br />Page 2 of 2 <br />