My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
431 ALVERSON BLVD 2024-01-03
>
Address Records
>
ALVERSON BLVD
>
431
>
431 ALVERSON BLVD 2024-01-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 8:17:38 AM
Creation date
10/24/2023 1:31:15 PM
Metadata
Fields
Template:
Address Document
Street Name
ALVERSON BLVD
Street Number
431
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ti <br />EVERETT <br />WASHINGTON <br />October 26, 2021 <br />Janet R. Soriano <br />431 Alverson Blvd <br />Everett, WA 98201 <br />CITY OF EVERETT <br />Permit Services <br />Email Address: janet-sorianol7@msn.com <br />RE: Owner: Janet R. Soriano <br />Job Address: 431 Alverson Blvd Everett, WA 98201 <br />Plan Check Number: B2108-011, First Building Review <br />Dear Janet Soriano, <br />-vv, IEDNOV,s zoz, <br />CITY OF EVERETT <br />Permit Services <br />We have reviewed the responses to the First Review letter dated September 28, 2021. Multiple <br />comments have not been completely addressed and require additional action before a permit can <br />be issued. The comments are itemized for consistency with the original review letter. These <br />comments address building issues only. Additional revisions or additions may be required by other <br />departments including Public Works, Planning, and Fire. <br />In order for the processing of your application to continue, the following documentation shall be <br />submitted to Permit Services for review: <br />a. Itemized letter addressing the comments provided below. <br />b. Two complete sets of revised construction drawings. <br />c. Two copies of supplemental structural calculations (if appliable). <br />Submittal documents should contain sufficient information and detail to review the proposed project <br />for compliance with the adopted building codes. Upon submittal of the revised documents, your <br />application will be given priority and the review will recommence. <br />Structural <br />2. See Sheet 2. Second level floor beams appear to be out of the scope of the prescriptive method <br />of the IRC. Floor beams with cantilevers supporting additional point loads are not permitted per <br />the IRC span tables. Structural calculations substantiating the design should be provided per <br />Section R301.1.3 or a revised design should be submi ed. <br />3. See Sheet 1 and 2. It appears that the floor framing on the second floor extends over the <br />location of the stairs. See location of the 13-foot long 4x10 floor beam. The beam extends over <br />the last few steps that lead into the second story outlook room. Provide framing information at <br />the top of the stairs. (See Architectural Comment 10, the section cut should provide this <br />information) <br />�%ffR <br />
The URL can be used to link to this page
Your browser does not support the video tag.