CITY OF EVERETT <br />EVERETT Permit Services <br />WASHINGTON <br />October 26, 2021 <br />Janet R. Soriano <br />431 Alverson Blvd <br />Everett, WA 98201 <br />Email Address: janet_soriano17@msn.com <br />RE: Owner: Janet R. Soriano <br />Job Address: 431 Alverson Blvd Everett, WA 98201 <br />Plan Check Number: B2108-011, First Building Review <br />Dear Janet Soriano, <br />We have reviewed the responses to the First Review letter dated September 28, 2021. Multiple <br />comments have not been completely addressed and require additional action before a permit can <br />be issued. The comments are itemized for consistency with the original review letter. These <br />comments address building issues only. Additional revisions or additions may be required by other <br />departments including Public Works, Planning, and Fire. <br />In order for the processing of your application to continue, the following documentation shall be <br />submitted to Permit Services for review: <br />a. Itemized letter addressing the comments provided below. <br />It. Two complete sets of revised construction drawings. <br />a Two copies of supplemental shuctural calculations (if appliable). <br />Submittal documents should contain sufficient information and detail to review the proposed project <br />for compliance with the adopted building codes. Upon submittal of the revised documents, your <br />application will be given priority and the review will recommence. <br />Structural <br />2. See Sheet 2. Second level floor beams appear to be out of the scope of the prescriptive method <br />of the IRC. Floor beams with cantilevers supporting additional point loads are not permitted per <br />the IRC span tables. Structural calculations substantiating the design should be provided per <br />Section R301.1.3 or a revised design should be submitted. <br />3. See Sheet 1 and 2. It appears that the floor framing on the second floor extends over the <br />location of the stairs. See location of the 13-foot long 4x10 floor beam. The beam extends over <br />the last few steps that lead into the second story outlook room. Provide framing information at <br />the top of the stairs. (See Architectural Comment 10, the section cut should provide this <br />information) <br />