My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2319 GALE PL 2023-10-31
>
Address Records
>
GALE PL
>
2319
>
2319 GALE PL 2023-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2023 11:02:50 AM
Creation date
10/25/2023 6:22:31 AM
Metadata
Fields
Template:
Address Document
Street Name
GALE PL
Street Number
2319
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INor- <br /> SUN BLUE RAVEN <br /> ■ ■ FRAME 1 <br /> Z 0 SOLAR <br /> so_____ -__SMICRORAILTM INSTALLATION GUIDE ; PAG-E <br /> __ _ ___________________________________________________________ _ _ __ _ <br /> SYSTEM LEVEL FIRE CLASSIFICATION <br /> The system fire class rating requires installation in the manner specified in the performance is inherent in the SFM design,and no additional mitigation measures <br /> SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to are required.The fire classification rating is valid for any roof pitch.There is no <br /> the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain <br /> incorporated into the UL 2703 product certification. SFM has achieved Class A, the Class A, B & C fire rating for SFM. SUNFRAME M ICRORAI L11 components shall <br /> B & C system level performance for low slope & steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. <br /> in conjunction with type 1 and type 2 modules. Class A, B & C system level fire <br /> Module Type Roof Slope System Level Fire Rating Microrail Direction Module Orientation Mitigation Required <br /> Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required <br /> U12 7 0 3 TEST MODULES <br /> See pages 22 and 23 for a list of modules that were electrically and mechanically tested or <br /> qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. <br /> • Maximum Area of Module = 27.76 sqft <br /> • UL2703 Design Load Ratings: <br /> a) Downward Pressure - 113 PSF / 5400 Pa <br /> b) Upward Pressure - 50 PSF / 2400 Pa <br /> C) Down-Slope Load - 21.6 PSF / 1034 Pa <br /> • Tested Loads: <br /> a) Downward Pressure - 170 PSF / 8000 Pa <br /> b) Upward Pressure - 75 PSF / 3500 Pa <br /> C) Down-Slope Load - 32.4 PSF / 1550 Pa <br /> • Maximum Span = 6ft <br /> • Use with a maximum over current protection device OCPD of 30A <br /> • System conforms to UL Std 2703, certified to LTR AE-001-2012 <br /> • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span <br /> • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult <br /> the PV module manufacturer's installation guide for more information <br /> • Down-Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less <br /> DRAWING NUMBER: <br /> SS <br />
The URL can be used to link to this page
Your browser does not support the video tag.