My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4715 W VIEW DR 2023-11-01
>
Address Records
>
W VIEW DR
>
4715
>
4715 W VIEW DR 2023-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 3:40:02 PM
Creation date
11/1/2023 2:32:15 PM
Metadata
Fields
Template:
Address Document
Street Name
W VIEW DR
Street Number
4715
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />Option 2B Rain Garden Design Worksheet <br />The top of the ponded surface area below the overflow shall be at least 13.5% of the net new impervious <br />surface area draining to the rain garden. Projects that have a greater contributing impervious area to <br />the BMP shall use the larger of the two areas, or as an alternative may have the BMP sized by an <br />Engineer using a continuous runoff model to meet the flow control requirements of Section 6.10 of the <br />DCSS. The table below provides design geometry based upon contributing impervious area. Refer to the <br />Rain Garden Handbook for Western Washington: A Guide for Design, Installation, and Maintenance <br />(Hinman et.al. 2013) for construction guidance. Bioretention shall be designed in accordance with <br />section 6.10 of the DCSS and the SWMMWW. Use the following criteria for design of the <br />bioretention pond. <br />The applicable Setback requirements in Section 4-4.1 (3) have been met, including: <br />• 50 feet setback from slopes greater than 15 percent and greater than 10 feet in height. <br />Side Slope = 3:1 <br />Minimum Infiltration Rate = 0.3 in/hr <br />Minimum depth of Biosoil = 12-inches <br />Ponding depth = 6-inches <br />Freeboard = 6-inches <br />Table 2B — Small <br />Ciontributin in <br />Area <br />Project Rain Garden Flow <br />:. <br />Ponding Area <br />54 <br />Control Des <br />• <br />. . ing <br />19 <br />200 to 400 <br />400 to 600 <br />81 <br />36 <br />600 to 800 <br />108 <br />55 <br />800 to 1000 <br />135 <br />74 <br />1000 to 1200 <br />162 <br />95 <br />1200 to 1400 <br />189 <br />116 <br />1400 to 1600 <br />216 <br />137 <br />1600 to 1800 <br />243 <br />158 <br />1800to 2000 <br />270 <br />180 <br />gin Sizing <br />■ Net new impervious area requiring mitigation (ft2): <br />■ Contributing impervious area to BMP: <br />■ Total contributing area including landscaped area (ft2): <br />Design Top of Ponded Surface Area (ft2) = 0.135*(contributing impervious area (ft2)) <br />ft2 <br />City of Everett Public Works <br />Small Project Stormwater Site Plan Report for Projects in 19 <br />the Combined Sewer Area-May2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.