Laserfiche WebLink
Do M u S Domus Structural Engineering, LLC <br /> S T R E) C T I t R A 1, P.O. Box 560 <br /> Broomfield, CO 80038 <br /> ENGINEER ING i. L (--, 530-864-7055 <br /> projects@domusstruc.com <br /> Lateral Check <br /> Existing Weight of Effected Building <br /> Level Area Weight(psf) Weight(lb) <br /> Roof 2146 sf 8.8 psf 18793 lb <br /> Ceding 2146 sf 6.0 psf 12876 lb <br /> Wood Siding 100 fl 5.0 psf 2000 lb (8'-0"WaH Height) <br /> Int Walls 1 100 It 1 6.4 psf 2560 lb <br /> Existing Weight of Effected Building 36229 lb <br /> Proposed Weight of PV System <br /> Weight ofPVSystem(Per Blue Raven Solar) 3.0 psf <br /> Approx.Area of Proposed PV System 192 sf <br /> Approximate Total Weight ofPVSystem 576 lb <br /> 100/oComparison <br /> 10%of Existing Building Weight(Allowed) 3623 lb <br /> Approximate Weight of PV System(Actual) 576 lb <br /> Percent Increase 1.6% <br /> 3623 lb>576 lb,Therefore OK <br /> Taft-Farren Everett WA 5 <br />