Domus <br /> co m If S Domus Structural Engineering, LLC <br /> J TRUCTI` RA1, P.O. Box 560 <br /> E N G I N E E R I N G I. L C Broomfield, CO 80038 <br /> 530-864-7055 <br /> projects@domusstruc.com <br /> Appendix A:General Notes <br /> GENERAL <br /> • The contractor shall verify all dimensions,property setbacks,AHJ/HOA CC&R's,elevations and site conditions before <br /> starting work and shall notify Domus Structural Engineering,LLC of any discrepancies. <br /> •All report conclusions represent Domus Structural Engineering,LLC's best professional judgment based upon industry <br /> standards. <br /> • Resolve any conflicts on the drawings with Domus Structural Engineering,LLC before proceeding with construction. <br /> • The design criteria used for this project&listed on the first page of the report is based on the engineers best judgement <br /> and/or provided by the ATC council.AHJ specific requests may differ.Please contact our team if the design criteria needs to <br /> be modified. <br /> •A site visit was not physically conducted by Domus Structural Engineering,LLC.The accompanying calculations and <br /> certification are provided with the understanding that the site building and construction standards meet an acceptable level of <br /> industry standards.It shall be the contractors responsibility to identify any irregularities such as inconsistent framing <br /> conditions,water damage,fire damage,cracked,split or noticeably deflecting framing members. <br /> • Domus Structural Engineering,LLC is not responsible for enforcing safety measures or regulations.The contractor shall <br /> design,construct,and maintain all safety devices including shoring and bracing,and shall be solely responsible for <br /> conforming to all local,state and federal safety and health standards,laws and regulations.The contractor shall take <br /> necessary precautions to maintain and insure the integrity of the structure during construction.If a lawsuit is filed by one of <br /> the contractor's or subcontractor's employees,or any one else,the contractor will indemnify,defend and hold the owner and <br /> Domus Structural Engineering,LLC harmless of any and all such claims. <br /> • Any and all waterproofing shall be provided by the contractor.Domus Structural Engineering,LLC is not responsible for <br /> waterproofing. <br /> •All hardware shall be installed per manufacturer specifications and within specified design limitations.Domus Structural <br /> Engineering,LLC assumes no responsibility for incorrectly installed hardware or hardware installed outside of the <br /> manfacturer specifications. <br /> USER RELIANCE <br /> 9 Domus Structural Engineering,LLC was engaged by Blue Raven Solar(Client)to perform this assessment.This report and <br /> the information therein,are for the exclusive use of the Client.This report has no other purpose and shall not be relied upon, <br /> or used,by any other person or entity without the written consent of Dous Structural Engineering,LLC.Third parties that <br /> obtain this report,or the information within shall have no rights of recourse or recovery against Domus Structural <br /> Engineering,LLC,it's officers or employees. <br /> ROOF MOUNTED ARRAYS <br /> • If an analysis of a supporting stucture is included in our scope of work,the structural assessment only applies to the section <br /> of the roof that is directly supporting the proposed solar PV system. <br /> • No structural members can be cut for conduit,etc.,unless specifically shown.Obtain prior written approval for installation of <br /> any additional conduit,etc. <br /> • It is assumed that a standard quality of construction care was used to construct the original building.It shall be the <br /> contractors responsibility to field verify any and all framing member supporting the proposed PV array are in adequate <br /> condition.The contractor shall field inspect for sub-standard construction means,signs of dry rot,mold,fire damage,etc.and <br /> notify engineer if any compromised material is found on site prior to starting construction. <br /> • It is assumed that there have been no additional loads(HVAC or MEP equipment,additional layers of roofing,etc)added to <br /> the building over the course of the structures histroy.The contractor and/or client shall verify this with the property owner and <br /> notify Domus Structural Engineering,LLC if additional load has been added to the structure already. <br /> • Flexible utility connections must be used at any building seismic joint. <br /> • Care should be taken to ensure that PV arrays do not preclude drainage of rain water. <br /> • Unless otherwise noted,construction material shall be evenly distributed if placed on framed floors or roofs.Loads shall not <br /> exceed the allowable loading for the supporting members and their connections. <br /> • All lags or wood screws at the roof shall be stainless steel and installed withing the middle 1/3 of the dimensional width of the <br /> framing members. <br /> •All fasteners shall be a minimum of 6"away from any truss panel or hinge joints,truss plates and/or member ends.Field <br /> verify location of fasteners prior to starting construction.All fasteners shall be pre-drilled to avoid splitting existing lumber. <br /> • Domus Structural Engineering,LLC is not responsible for downslope effects of snow shedding or sliding off of the PV array <br /> nor any damage to downslope decks,roofs,walkways,landscaping,automobiles,pets,people,etc..If snow guards are <br /> requested by the customer,notify Domus Structural Engineering,LLC. <br /> Taft-Farren Everett WA 6 <br />