Laserfiche WebLink
Retrofit Description <br /> Minor blocking required to reinforced sheathing deck due to firedamage per site survey located <br /> in Roof 1. Minor retrofit required for rafter due to fire damage. The retrofit shall consist of sisters <br /> for the existing 2x4 rafter, with 16d common nails at 24" O.C., staggered. Sisters shall begin and <br /> end between 0" and 18" from rafter ends. <br /> Additional Retrofit Details and Notes <br /> ROOF SNEAT»NG <br /> ���MSN• - " <br /> • RIOGE BOARD <br /> (WHERE APPLIES, <br /> `,t • EXISTING <br /> �8 �P RAFTER <br /> IM STAGGERED <br /> SINKERS <br /> NEW SISTERED RAFTER <br /> ATTACHED TO EXISTING <br /> R TFR WITH 160 <br /> STAGGEREDSINKERS <br /> 1a CLAIAG JOIST <br /> NOTES: <br /> 1 ALL MEMBERS SHOWN ARE EXISTING <br /> 'AR.+W", UNLESS LABELLED(N)OR NEW <br /> 2. SISTER MAY BE INSTALLED AS TWO <br /> SEPARATE PIECES WITH ONE LENGTH <br /> INSTALLED ON EACH SIDE OF THE EXISTING <br /> RAFTER THE TWO SEPARATE LENGTHS <br /> SHALL OVERLAP A MINIMUM DISTANCE OF <br /> T-0' <br /> 1 RETROFIT REQUIRED AT ROOF AREAS <br /> SUPPORTING SOLAR PANELS ONLY.UNLESS <br /> NOTED OTHERWISE IN LETTER. <br /> Pictures of poor condition - area to be retrofit (where applies) <br /> r <br /> t ? <br /> 4 <br />