Laserfiche WebLink
s Everett M <br />m A I <br />SITE 3 <br />FURN I SH I N65 PLAN .3 „�,:� F yq <br />p <br />3%v <br />v <br />1/4" s <br />VICINITY MAP <br />N.T.S. <br />NORiH <br />1 <br />I � <br />A <br />re EIA or 4 II d' <br />I' 1 <br />i° <br />1.. <br />at <br />SITE PLAN <br />1. . M'-1. <br />rnar6 <br />SPRINKLER LEGEND <br />SYM. <br />TYPE <br />K-FACT. <br />FINISH <br />ORIFICE <br />TEMP. <br />QTY. <br />Victaulic V2708 Quick Response Pendant <br />5.6 <br />Chrome <br />112" <br />155 <br />2 <br />Victaulic V2704 Quick Response Upright <br />5.6 <br />Brass <br />1/2" <br />155 <br />Victaulic V3606 Dry Pendant <br />5.6 <br />Brass <br />112" <br />200 <br />Existing pendant sprinkler location <br />5.6 <br />Chrome <br />112" <br />155 <br />Victaulic V6606 Quick Response Concealed Pendant <br />5.6 <br />Chrome <br />1121, <br />155 <br />TOTAL <br />2 <br />TENANT IMPROVEMENT NOTES <br />1. System designed per 2019 NFPA #13 edition and City of Everett. <br />2. All new pendant sprinkler heads to be 155 degree quick response pendants. <br />3. All existing sprinkler heads are quick response. <br />4. All materials used shall be UL/FM approved for fire protection installations. <br />5. All threaded joints to have ductile iron fittings. <br />6. All new 1r-2" piping to be black steel Sch. 40, 21/2" and larger piping to be Sch. 10. <br />7. System shall be put back into service at the end of each work day. <br />8. Pipe hangers and method of hanging to be in accordance with NFPA #13. <br />9. All tests required witnessed by authority having jurisdiction. Monitoring and central <br />alarm are existing and to remain and maintained by owner. <br />11. All piping sized per existing pipe schedule method per NFPA 913. <br />12. Total Sprinklers; <br />(A) = Add New Fire Sprinklers Qty: 2 <br />(R) = Relocate Existing Sprinkler to New Location Qty: <br />(C) = Change Existing S.R. Sprinkler to New Q.R. Sprinkler Qty: <br />(E) = Existing Sprinkler Location Qty: <br />DESIGN CRITERIA <br />PER 2019 NFPA #13 EDITION LIGHT HAZARD OCCUPANCY. <br />HYDRAULIC CALCULATIONS HAVE NOT BEEN PROVIDED WITH THIS <br />SUBMITTAL. <br />Related Permit # <br />Parcel # 28051800404800 <br />Architect: General Contractor: <br />2012 Architects CPM Tenant Improvements <br />Adam Clark Bill Hatfield <br />425-252-2153 425-361-5313 <br />wASNINGTON STATE - <br />CERTIFICATE OF COMPETENCY <br />FIRE PROTECTION SPRINKLER SYSTEMS: <br />Douglas A. Buehler <br />4327-0797-CEG Lev613 <br />• AmmeeTT�Iee99n Xgpnkler Corporation <br />AMERISC9F7NC i i <br />REVISIONS <br />AM6fj1 CAN SPR \CORPORATION <br />2311 153rd Ave BE Snohomish, We 98290 Phone: 425-3354645 Fax: 425-335-476_6__ <br />APPROVING AGENCIES <br />CUSTOMER: <br />Angry Crab Shack <br />City of Everett <br />ADDRESS: <br />1321 SE Everett Mall Way <br />Everett, Washington 98208 <br />JOB NO. <br />DRAWN BY: <br />DATE <br />SCALE <br />DRAWING NO. <br />NA <br />Doug <br />8/7/2023 <br />1/4" = 1'41 <br />1 of 1 <br />