1=1 ICKI T C:- 1 T \IrG, PI A\I <br />o Everett <br />ew. `rl/d,7 <br />itM'IW y <br />f"e�e <br />VICINITY MAP <br />N.T.5 <br />Permit#: K2308-002 <br />Site Address: 1321 SE Everett Mall Way <br />Applicant: American Sprinkler Corporation <br />Application Date: 08/07/2023 <br />Description: Add and relocate fire sprinklers for new <br />walls and ceilings _ <br />Review Status: tat Review by City & Peer Reviewers TENANT IMPROVEMENT NOTES <br />Review Date: 08/07/2023 <br />1. System designed per 2019 NFPA #13 edition and City of Everett. <br />2. All new pendant sprinkler heads to be 155 degree quick response pendants. <br />EVERETT 3. All existing sprinkler heads are quick response. <br />Everett Fire Dept. Permit Review 4. All materials used shall be UL/FM approved for fire protection installations. <br />Status: Approved 5. All threaded joints to have ductile iron fittings. <br />Reviewed By: K131— 6. All new 1"-2" piping to be black steel Sch. 40, 21/2" and larger piping to be Sch. 10. <br />08/07/2023 3:12:00 7. System shall be put back into service at the end of each work day. <br />PM 8. Pipe hangers and method of hanging to be in accordance with NFPA #13. <br />9. All tests required witnessed by authority having jurisdiction. Monitoring and central <br />APPROVED alarm are existing and to remain and maintained by owner. <br />PUBLIC WORKS DEPARTMENT 11. All piping sized per existing pipe schedule method per NFPA 913. <br />BY: Thad Newport 12. Total Sprinklers; <br />DATE: 08/12/2023 (A) = Add New Fire Sprinklers Qty: 2 <br />CITY OF EVERETT REVIEWED FOR PERMIT (R) = Relocate Existing Sprinkler to New Location Qty: <br />(C) = Change Existing S.R. Sprinkler to New Q.R. Sprinkler Qty: <br />(E) = Existing Sprinkler Location Qty: <br />DESIGN CRITERIA <br />PER 2019 NFPA #13 EDITION LIGHT HAZARD OCCUPANCY. <br />HYDRAULIC CALCULATIONS HAVE NOT BEEN PROVIDED WITH THIS <br />SUBMITTAL. <br />Related Permit # <br />Parcel # 28051800404800 <br />Architect: General Contractor: <br />2012 Architects CPM Tenant Improvements <br />Adam Clark Bill Hatfield <br />425-252-2153 425-361-5313 <br />- <br />�"�� <br />I^ 1 <br />lmo ��., 1• <br />SITE PLAN <br />1. . M'-0' <br />rnarH <br />SPRINKLER LEGEND <br />SYM. <br />TYPE <br />K-FACT. <br />FINISH <br />ORIFICE <br />TEMP. <br />QTY. <br />Victaulic V2708 Quick Response Pendant <br />5.6 <br />Chrome <br />112" <br />155 <br />2 <br />Victaulic V2704 Quick Response Upright <br />5.6 <br />Brass <br />1/2" <br />155 <br />Victaulic V3606 Dry Pendant <br />5.6 <br />Brass <br />112" <br />200 <br />Existing pendant sprinkler location <br />5.6 <br />Chrome <br />112" <br />155 <br />Victaulic V6606 Quick Response Concealed Pendant <br />5.6 <br />Chrome <br />1121, <br />155 <br />TOTAL <br />2 <br />wASNINGTON STATE - <br />CERTIFICATE OF COMPETENCY <br />FIRE PROTECTION SPRINKLER SYSTEMS: <br />Douglas A. Buehler <br />4327-0797-CEG Lava13 <br />• AmmeeTT�Iee99n Xgy+nkler Corporation <br />AMERISC9F7NC , , <br />REVISIONS <br />AM791 CAN SPIRCORPORATION <br />2311 153rd Ave BE Snohomish, We 98290 Phone: 425-3354645 Fax: 425-335-476_6__ <br />APPROVING AGENCIES <br />CUSTOMER: <br />Angry Crab Shack <br />City of Everett <br />ADDRESS: <br />1321 SE Everett Mall Way <br />Everett, Washln ton 98208 <br />JOB NO. <br />DRAWN BY: <br />DATE <br />SCALE <br />DRAWING NO. <br />NA <br />Doug <br />8l712023 <br />1/4" = 1'.0" <br />1 oil <br />